An Empirical Study on Assessment Method for Aging Medium & Large Oil-immersed Power Transformers

被引:0
|
作者
Chang, Jeong-Ho [1 ]
Oh, Seung-Chan [2 ]
Lee, Heung-Ho [1 ]
机构
[1] Chung Nam Natl Univ, Dept Elect & Elect Engn, Taejon, South Korea
[2] Korea Atom Energy Res Inst, Taejon, South Korea
关键词
Transformer; Asset management; Technical evaluation; Reliability assessment;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There has been fewer new hydraulic power plants being built in Korea, and the existing power equipment has gradually been aged. Understandably, older plants require more maintenance to keep up the system performance. An effective asset management of power equipment has become a great necessity from both economical and technical aspects. This paper investigated a Risk-Based Maintenance (RBM) method that consists of technical assessment and economical assessment to make an efficient reliability assessment.
引用
收藏
页码:731 / 735
页数:5
相关论文
共 50 条
  • [32] A review of temperature prediction methods for oil-immersed transformers
    Guo, Yi
    Chang, Yuan
    Lu, Bing
    MEASUREMENT, 2025, 239
  • [33] Fault diagnosis method for oil-immersed transformers integrated digital twin model
    Yao, Haiyan
    Zhang, Xin
    Guo, Qiang
    Miao, Yufeng
    Guan, Shan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [34] The Characterization Analysis of the Oil-Immersed Transformers Obtained by Area Elimination Method Design
    Thungsuk, Nuttee
    Mungkung, Narong
    Tanaram, Thaweesak
    Chaithanakulwat, Arckarakit
    Arunrungsusmi, Somchai
    Poonthong, Wittawat
    Songruk, Apidat
    Tunlasakun, Khanchai
    Chunkul, Chalathip
    Tanitteerapan, Tanes
    Yuji, Toshifumi
    Kinoshita, Hiroyuki
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [35] Simulation study on oil pressure problems caused by internal faults in oil-immersed transformers
    Yao, Haowei
    Lv, Kefeng
    Lou, Zhen
    Xing, Mengyang
    Qin, Hengjie
    Song, Huaitao
    Lv, Zhongbin
    Wang, Dong
    Wang, Zhenyu
    Ren, Wei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 175 : 190 - 198
  • [36] A Methodology for Diagnosing Faults in Oil-Immersed Power Transformers Based on Minimizing the Maintenance Cost
    Lin, Ming-Jong
    Chen, Liang-Bi
    Yu, Chao-Tang
    IEEE ACCESS, 2020, 8 : 209570 - 209578
  • [37] Numerical analysis and experimental research of vibration and noise characteristics of oil-immersed power transformers
    Miao, Xuhong
    Jiang, Pei
    Pang, Fuzhen
    Tang, Yang
    Li, Haichao
    Qu, Guanglei
    Li, Jun
    APPLIED ACOUSTICS, 2023, 203
  • [38] State-of-the-art review on asset management methodologies for oil-immersed power transformers
    Jin, Lan
    Kim, Dowon
    Abu-Siada, Ahmed
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 218
  • [39] Correlation between Hot-Spot Temperature and Aging Factor of Oil-Immersed Current Transformers
    Vanegas, Diego M. Robalino
    Mahajan, Satish M.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2164 - 2168
  • [40] New perspectives to overloading with accurate modeling of thermal transients in oil-immersed power transformers
    Van der Veken, W
    Declercq, J
    Baelmans, M
    Van Mileghem, S
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 147 - 152