The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams

被引:48
|
作者
Khatonabadi, Maryam [1 ,2 ]
Kim, Hyun J. [1 ,2 ]
Lu, Peiyun [1 ,2 ]
McMillan, Kyle L. [1 ,2 ]
Cagnon, Chris H. [1 ,2 ]
DeMarco, John J. [3 ,4 ]
McNitt-Gray, Michael F. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Dept Biomed Phys, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90024 USA
[3] Univ Calif Los Angeles, Dept Biomed Phys, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90095 USA
关键词
CT; CTDIvol; regional CTDIvol; tube current modulation; radiation dose; organ dose; Monte Carlo dose simulations; MONTE-CARLO SIMULATIONS; ATTENUATION-BASED ESTIMATION; MULTIDETECTOR CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CONVERSION COEFFICIENTS; QUALITY-ASSURANCE; PATIENT SIZE; REDUCTION; PHANTOMS;
D O I
10.1118/1.4798561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDIvol. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32 chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDIvol (CTDIvol,global) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDIvol values, referred to as regional and organ-specific CTDIvol, were calculated for each patient. Using an approach similar to TG 204, all CTDIvol values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDIvol values. For example, when estimating dose to the liver, CTDIvol,global yielded a R-2 value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDIvol for abdomen and liver, respectively. For breast dose, the global CTDIvol yielded a R-2 value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDIvol for chest and breasts, respectively. The R-2 values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDIvol as normalization factors when using TCM. It was demonstrated that CTDIvol,global is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDIvol descriptors that account for local variations in scanner output present when TCM is employed. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Evaluating Size-Specific Dose Estimate (SSDE) as an estimate of organ doses from routine CT exams derived from Monte Carlo simulations
    Hardy, Anthony James
    Bostani, Maryam
    Kim, Grace Hyun J.
    Cagnon, Christopher H.
    Zankl, Maria Agnes
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2021, 48 (10) : 6160 - 6173
  • [22] CTDIvol: a suitable normalization for CT dose conversion coefficients at different tube voltages?
    Schlattl, Helmut
    Zankl, Maria
    Hoeschen, Christoph
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [23] Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation
    Hardy, A.
    Bostani, M.
    McMillan, K.
    Zankl, M.
    Cagnon, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3773 - 3773
  • [24] Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current
    Li, Xinhua
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2017, 44 (10) : 5413 - 5422
  • [25] The Effects of Patient Size on Organ Doses in Adaptive Tube Current Modulated CT
    Fisher, R.
    Hintenlang, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [26] Prospective estimation of organ dose in CT under tube current modulation
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL PHYSICS, 2015, 42 (04) : 1575 - 1585
  • [27] Implementation of Tube Current Modulation into An Organ Dose Calculator for CT Patients
    Lee, C.
    Yeom, Y.
    Atkinson, J.
    Folio, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E264 - E264
  • [28] Creation of Patient Size Dependent Methods of Estimating Organ Doses in Tube-Current Modulated MDCT Exams
    Fisher, R.
    Hintenlang, D.
    Arreola, M.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Estimating organ doses from tube current modulated CT examinations using a generalized linear model
    Bostani, Maryam
    McMillan, Kyle
    Lu, Peiyun
    Kim, Grace Hyun J.
    Cody, Dianna
    Arbique, Gary
    Greenberg, S. Bruce
    DeMarco, John J.
    Cagnon, Chris H.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2017, 44 (04) : 1500 - 1513
  • [30] The Relationship of Image Noise and Organ Dose as a Function of Patient Size for Abdominal CT Exams at 5 Different Dose Levels When Tube Current Modulation Is Used
    Zhang, D.
    Khatonabadi, M.
    Cagnon, C.
    DeMarco, J.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3925 - 3925