RETINAL VESSEL DETECTION IN WIDE-FIELD FLUORESCEIN ANGIOGRAPHY WITH DEEP NEURAL NETWORKS: A NOVEL TRAINING DATA GENERATION APPROACH

被引:0
|
作者
Ding, Li [1 ]
Kuriyan, Ajay [2 ]
Ramchandran, Rajeev [2 ]
Sharma, Gaurav [1 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14620 USA
[2] Univ Rochester, Dept Ophthalmol, Rochester, NY USA
关键词
Fluorescein angiography; vessel detection; generative adversarial networks; deep learning; retinal image analysis; BLOOD-VESSELS; SEGMENTATION; IMAGES;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Retinal blood vessel detection is a crucial step in automatic retinal image analysis. Recently, deep neural networks have significantly advanced the state of the art for retinal blood vessel detection in color fundus (CF) images. Thus far, similar gains have not been seen in fluorescein angiography (FA) because the FA modality is entirely different from CF and annotated training data has not been available for FA imagery. We address retinal vessel detection in wide-field FA images with generative adversarial networks (GAN) via a novel approach for generating training data. Using a publicly available dataset that contains concurrently acquired pairs of CF and fundus FA images, vessel maps are detected in CF images via a pre-trained neural network and registered with fundus FA images via parametric chamfer matching to a preliminary FA vessel detection map. The coaligned pairs of vessel maps (detected from CF images) and fundus FA images are used as ground truth labeled data for de novo training of a deep neural network for FA vessel detection. Specifically, we utilize adversarial learning to train a GAN where the generator learns to map FA images to binary vessel maps and the discriminator attempts to distinguish generated vs. ground-truth vessel maps. We highlight several important considerations for the proposed data generation methodology. The proposed method is validated on VAMPIRE dataset that contains high-resolution wide-field FA images and manual annotation of vessel segments. Experimental results demonstrate that the proposed method achieves an estimated ROC AUC of 0.9758.
引用
收藏
页码:356 / 360
页数:5
相关论文
共 50 条
  • [21] Novel artificial intelligence-assisted optical coherence tomography-angiography delineation of retinal vessels and leakage by deep learning with fluorescein angiography video training data
    Murata, Toshinori
    Hirano, Takao
    Mizobe, Hideaki
    Toba, Shuhei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (09)
  • [22] Peripheral areas of nonperfusion in treated central retinal vein occlusion as imaged by wide-field fluorescein angiography (vol 31, pg 829, 2011)
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (05): : E15 - E15
  • [23] Deep Learning-Based Segmentation and Quantification of Retinal Capillary Non-Perfusion on Ultra-Wide-Field Retinal Fluorescein Angiography
    Nunez do Rio, Joan M.
    Sen, Piyali
    Rasheed, Rajna
    Bagchi, Akanksha
    Nicholson, Luke
    Dubis, Adam M.
    Bergeles, Christos
    Sivaprasad, Sobha
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 11
  • [24] Fully Automated Detection of Abnormal Capillaries in Ultra-Wide-Field Fluorescein Angiography of Branch Retinal Vein Occlusion
    Reed, David Carleton
    Shah, Sanket U.
    Zutis, Kris
    Trucco, Emanuele
    Hubschman, Jean-Pierre
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [25] RetinaSim: Synthetic, whole-retina blood vessel networks for training deep neural networks and simulating retinal pathophysiology
    Brown, Emmeline Elizabeth
    Guy, Andrew
    Holroyd, Natalie
    Shipley, Rebecca
    Rajendram, Ranjan
    Walker-Samuel, Simon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [26] ULTRA WIDE-FIELD FUNDUS FLUORESCEIN ANGIOGRAPHY-GUIDED PASCAL LASER TARGETED RETINAL PHOTOCOAGULATION AS A FIRST TREATMENT OPTION FOR THE MANAGEMENT OF PROLIFERATIVE AND EXUDATIVE VASCULAR RETINAL DISORDERS
    Tsamis, E.
    Chwiejczak, K.
    Biswas, S.
    Stanga, P. E.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (04) : E106 - E106
  • [27] Increased vessel length index in deep retinal layer angiography en face slabs via convolutional neural networks
    Lewis, Warren
    Bhattacharya, Arindam
    de Sisternes, Luis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)
  • [28] Turbulence Profiling Neural Networks Using Imaging Shack-Hartmann Data for Wide-Field Image Correction
    Hamilton, R. J.
    Hart, Michael
    ADAPTIVE OPTICS SYSTEMS VIII, 2022, 12185
  • [29] Automated Quality Optimized Phase Selection in Ultra-widefield Angiography Using Retinal Vessel Segmentation with Deep Neural Networks
    Sevgi, Duriye Damla
    Hach, Jenna
    Srivastava, Sunil K.
    Wykoff, Charles
    O'connell, Margaret
    Whitney, Jon
    Reese, Jamie
    Ehlers, Justis P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)
  • [30] Normative intercapillary distance and vessel density data in the temporal retina assessed by wide-field spectral-domain optical coherence tomography angiography
    Liu, Keke
    Guo, Yukun
    You, Qisheng
    Hormel, Tristan
    Hwang, Thomas S.
    Jia, Yali
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2021, 246 (20) : 2230 - 2237