The phase shift of an ultrasonic pulse at an oil layer and determination of film thickness

被引:46
|
作者
Reddyhoff, T
Kasolang, S
Dwyer-Joyce, RS
Drinkwater, BW
机构
[1] Univ Sheffield, Dept Mech Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Bristol, Dept Mech Engn, Bristol, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
oil film thickness measurement; ultrasound; phase difference; phase shift; ultrasonic reflection;
D O I
10.1243/135065005X34044
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An ultrasonic pulse incident on a lubricating oil film in a machine element will be partially reflected and partially transmitted. The proportion of the wave amplitude reflected, termed the reflection coefficient, depends on the film thickness and the acoustic properties of the oil. When the appropriate ultrasonic frequency is used, the magnitude of the reflection coefficient can be used to determine the oil film thickness. However, the reflected wave has both a real component and an imaginary component, and both the amplitude and the phase are functions of the film thickness. The phase of the reflected wave will be shifted from that of the incident wave when it is reflected. In the present study, this phase shift is explored as the film changes and is evaluated as an alternative means to measure oil film thickness. A quasi-static theoretical model of the reflection response from an oil film has been, developed. This model relates the phase shift to the wave frequency and the film properties. Measurements of reflection coefficient from a static model oil film and also from a rotating journal bearing have been recorded. These have been used to determine the oil film thickness using both amplitude and phase shift methods. In both cases, the results agree closely with independent assessments of the oil film thickness. The model of ultrasonic reflection is further extended to incorporate mass and damping terms. Experiments show that both the mass and the internal damping of the oil films tested in this work have a negligible effect on ultrasonic reflection. A potentially very useful application for the simultaneous measurement of reflection coefficient amplitude and phase is that the data can be used to negate the need for a reference. The theoretical relationship between phase and amplitude is fitted to the data. An extrapolation is performed to determine the values of amplitude and phase for an infinitely thick layer. This is equivalent to the reference signal determined by measuring the reflection coefficient directly, but importantly does not require the materials to be separated. This provides a simple and effective means of continuously calibrating the film measurement approach.
引用
收藏
页码:387 / 400
页数:14
相关论文
共 50 条
  • [21] Thin oil-film thickness distribution measurement using ultrasonic arrays
    Zhang, Jie
    Drinkwater, Bruce W.
    NDT & E INTERNATIONAL, 2008, 41 (08) : 596 - 601
  • [22] Review of ultrasonic-based technology for oil film thickness measurement in lubrication
    Dou, Pan
    Jia, Yaping
    Zheng, Peng
    Wu, Tonghai
    Yu, Min
    Reddyhoff, Tom
    Peng, Zhongxiao
    TRIBOLOGY INTERNATIONAL, 2022, 165
  • [23] Ultrasonic technique for measurement of oil-film thickness in metal cold rolling
    Adeyemi, G. J.
    Dwyer-Joyce, R. S.
    Stephen, J. T.
    Adebayo, A.
    TRIBOLOGY-MATERIALS SURFACES & INTERFACES, 2022, 16 (02) : 177 - 186
  • [24] Oil film thickness measurement system of crankshaft based on ultrasonic reflection signal
    Zhang Y.
    Liang G.
    Cao C.
    Tang Z.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2022, 62 (09): : 1484 - 1491
  • [25] Temperature compensation strategy for ultrasonic-based measurement of oil film thickness
    Jia, Yaping
    Wu, Tonghai
    Dou, Pan
    Yu, Min
    WEAR, 2021, 476
  • [26] PHASE SHIFT CORRECTIONS FOR INFRARED INTERFERENCE MEASUREMENT OF EPITAXIAL LAYER THICKNESS
    SCHUMANN, PA
    PHILLIPS, RP
    OLSHEFSK.PJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1966, 113 (04) : 368 - &
  • [27] A CMOS COMPATIBLE GHZ ULTRASONIC PULSE PHASE SHIFT BASED TEMPERATURE SENSOR
    Abdelmejeed, Mamdouh
    Kuo, Justin C.
    Lal, Amit
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 1108 - 1111
  • [28] Thickness determination of dual-layer coatings based on ultrasonic spectral filtering
    Ma, Z. Y.
    Zhang, W.
    Luo, Z. B.
    Lin, L.
    Krishnaswamy, S.
    INSIGHT, 2018, 60 (04) : 200 - 205
  • [29] Ultrasonic measurement of oil film thickness between the roller and the inner raceway in a roller bearing
    Zhang, Kai
    Meng, Qingfeng
    Chen, Wei
    Li, Junning
    Harper, Phil
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2015, 67 (06) : 531 - 537
  • [30] Phase-shift imaging ellipsometer for measuring thin-film thickness
    Yu, Chih-Jen
    Hung, Ching-Hung
    Hsu, Kuei-Chu
    Chou, Chien
    MICROELECTRONICS RELIABILITY, 2015, 55 (02) : 352 - 357