Corneal haze is reduced by amniotic membrane matrix in excimer laser photoablation in rabbits

被引:0
|
作者
Wang, M [1 ]
Gray, T [1 ]
Prabhasawat, P [1 ]
Ma, X [1 ]
Ding, FY [1 ]
Hernandez, E [1 ]
Sanabria, O [1 ]
Culbertson, W [1 ]
Hanna, K [1 ]
Forster, RK [1 ]
Tseng, SCG [1 ]
机构
[1] UNIV MIAMI,SCH MED,BASCOM PALMER EYE INST,OCULAR SURFACE & TEAR CTR,MIAMI,FL
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
引用
收藏
页码:1908 / 1908
页数:1
相关论文
共 50 条
  • [41] On the structural origin of refractive instability and corneal haze after excimer laser keratectomy for myopia
    Moller-Pedersen, T
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2003, 81 : 6 - 20
  • [42] Electron microscopic observations of the processing of cell debris after excimer laser photoablation in rabbit corneal stroma
    Tanaka, T
    Nishida, T
    Yamaguchi, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 281 - 281
  • [43] MODULATION OF CORNEAL WOUND-HEALING FOLLOWING EXCIMER LASER PHOTOABLATION USING INTERFERON-GAMMA
    WALLINE, TA
    PIEBENGA, LW
    BEALER, LA
    RUPANI, M
    MARDELLI, PG
    JAFFE, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 803 - 803
  • [44] Identical excimer laser PTK treatments in rabbits result in two distinct haze responses
    McCally, Russell L.
    Connolly, Patrick J.
    Stark, Walter J.
    Jain, Sandeep
    Azar, Dimitri T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (10) : 4288 - 4294
  • [45] Mitomycin C reduces haze formation in rabbits after excimer laser photorefractive keratectomy
    Xu, HZ
    Liu, SZ
    Xia, XB
    Huang, PG
    Wang, PB
    Wu, XY
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (03) : 342 - 349
  • [46] Retroviral gene therapy vectors for prevention of excimer laser-induced corneal haze
    Behrens, A
    Gordon, EM
    Li, L
    Liu, PX
    Chen, ZH
    Peng, HJ
    La Bree, L
    Anderson, WF
    Hall, FL
    McDonnell, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (04) : 968 - 977
  • [47] A novel method for generating corneal haze in anterior stroma of the mouse eye with the excimer laser
    Mohan, Rajiv R.
    Stapleton, W. Michael
    Sinha, Sunilima
    Netto, Marcelo V.
    Wilson, Steven E.
    EXPERIMENTAL EYE RESEARCH, 2008, 86 (02) : 235 - 240
  • [48] OBJECTIVE MEASUREMENT OF CORNEAL HAZE IN HUMAN CORNEAS FOLLOWING EXCIMER-LASER KERATECTOMY
    BRAUNSTEIN, RE
    STARK, WJ
    MCCALLY, RL
    CONNOLLY, PJ
    AZAR, DT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2013 - 2013
  • [49] OBJECTIVE MEASUREMENT OF CORNEAL HAZE AFTER EXCIMER-LASER PHOTOREFRACTIVE KERATECTOMY BY FLUOROPHOTOMETRY
    JIMENEZALFARO, I
    DELCASTILLO, JMB
    GARCIAFEIJOO, J
    CASTILLO, A
    ARIAS, A
    GARCIASANCHEZ, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S713 - S713
  • [50] Persistent corneal haze after excimer laser photokeratectomy in plasminogen-deficient mice
    Drew, AF
    Schiman, HL
    Kombrinck, KW
    Bugge, TH
    Degen, JL
    Kaufman, AH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (01) : 67 - 72