High-Resolution 3D MR Microangiography of the Rat Ocular Circulation

被引:19
|
作者
Shih, Yen-Yu I. [1 ,2 ]
Muir, Eric R. [2 ]
Li, Guang [2 ]
De La Garza, Bryan H. [2 ]
Duong, Timothy Q. [2 ,3 ,4 ,5 ,6 ]
机构
[1] Univ N Carolina, Dept Neurol, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Res Imaging Inst, San Antonio, TX 78229 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Ophthalmol, San Antonio, TX 78229 USA
[4] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiol, San Antonio, TX 78229 USA
[5] Univ Texas Hlth Sci Ctr San Antonio, Dept Physiol, San Antonio, TX 78229 USA
[6] S Texas Vet Hlth Care Syst, San Antonio, TX USA
基金
美国国家卫生研究院;
关键词
RETINAL BLOOD-FLOW; SCANNING LASER OPHTHALMOSCOPY; FUNCTIONAL MRI; CARBON-DIOXIDE; OXYGEN; HYPEROXIA;
D O I
10.1148/radiol.12112033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop high-spatial-resolution magnetic resonance (MR) microangiography techniques to image the rat ocular circulation. Materials and Methods: Animal experiments were performed with institutional Animal Care Committee approval. MR microangiography (resolution, 84 x 84 x 84 mu m or 42 x 42 x 84 mu m) of the rat eye (eight rats) was performed by using a custom-made small circular surface coil with an 11.7-T MR unit before and after monocrystalline iron oxide nanoparticle (MION) injection. MR microangiography measurements were made during air, oxygen, and carbogen inhalation. From three-dimensional MR microangiography, the retina was virtually flattened to enable en face views of various retinal depths, including the retinal and choroidal vascular layers. Signal intensity changes within the retinal or choroidal arteries and veins associated with gas challenges were analyzed. Statistical analysis was performed by using paired t tests, with P < .05 considered to indicate a significant difference. Bonferroni correction was used to adjust for multiple comparisons. Results: The central retinal artery, long posterior ciliary arteries, and choroidal vasculature could be distinguished on MR microangiograms of the eye. With MR microangiography, retinal arteries and veins could be distinguished on the basis of blood oxygen level-dependent contrast. Carbogen inhalation-enhanced MR microangiography signal intensity in both the retina (P = .001) and choroid (P = .027) compared with oxygen inhalation. Carbogen inhalation showed significantly higher signal intensity changes in the retinal arteries (P = .001, compared with oxygen inhalation), but not in the veins (P = .549). With MION administration, MR microangiography depicted retinal arterial vasoconstriction when the animals were breathing oxygen (P = .02, compared with animals breathing air). Conclusion: MR microangiography of the eye allows depth-resolved imaging of small angiographic details of the ocular circulation. This approach may prove useful in studying microvascular pathologic findings and neurovascular dysfunction in the eye and retina. (C) RSNA, 2012
引用
收藏
页码:234 / 241
页数:8
相关论文
共 50 条
  • [21] High-Resolution 3D Printing for Electronics
    Park, Young-Geun
    Yun, Insik
    Chung, Won Gi
    Park, Wonjung
    Lee, Dong Ha
    Park, Jang-Ung
    ADVANCED SCIENCE, 2022, 9 (08)
  • [22] High-resolution 3D printing in seconds
    Cameron Darkes-Burkey
    Robert F. Shepherd
    Nature, 2020, 588 : 594 - 595
  • [23] High-resolution 3D mapping of loops
    Linda Koch
    Nature Reviews Genetics, 2015, 16 (2) : 68 - 68
  • [24] HIGH-RESOLUTION VARIABLE FLIP ANGLE 3D MR IMAGING OF TRABECULAR MICROSTRUCTURE INVIVO
    JARA, H
    WEHRLI, FW
    CHUNG, H
    FORD, JC
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) : 528 - 539
  • [25] Predicting the Onset of Ischemic Stroke With Fast High-Resolution 3D MR Spectroscopic Imaging
    Lin, Zengping
    Meng, Ziyu
    Wang, Tianyao
    Guo, Rong
    Zhao, Yibo
    Li, Yudu
    Bo, Bin
    Guan, Yue
    Liu, Jun
    Zhou, Hong
    Yu, Xin
    Lin, David J.
    Liang, Zhi-Pei
    Nachev, Parashkev
    Li, Yao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (03) : 838 - 847
  • [26] SPINAL MR IMAGING - MULTIPLANAR REPRESENTATION FROM A SINGLE HIGH-RESOLUTION 3D ACQUISITION
    SHERRY, CS
    HARMS, SE
    MCCROSKEY, WK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 859 - 862
  • [27] RAPID HIGH-RESOLUTION 3D IMAGING IN MR DIAGNOSIS OF DISEASES OF THE KNEE-JOINT
    SKALEJ, M
    BONGERS, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (05): : 528 - 534
  • [28] High-Resolution In Utero 3D MR Imaging of Inner Ear Microstructures in Fetal Sheep
    Buhk, J. -H.
    Frisch, M.
    Yamamura, J.
    Graessner, J.
    Adam, G.
    Wedegaertner, U.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) : 2043 - 2046
  • [29] High-Resolution 3D Radial bSSFP with IDEAL
    Moran, Catherine J.
    Brodsky, Ethan K.
    Bancroft, Leah Henze
    Reeder, Scott B.
    Yu, Huanzhou
    Kijowski, Richard
    Engel, Dorothee
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 95 - 104
  • [30] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738