Inter- and intra-observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STAN

被引:49
|
作者
Westerhuis, M. E. M. H. [1 ]
van Horen, E. [1 ]
Kwee, A. [1 ]
van der Tweel, I. [2 ]
Visser, G. H. A. [1 ]
Moons, K. G. M. [3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Obstet & Gynaecol, Locat Wilhelmina Childrens Hosp, NL-3508 AB Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Biostat, Julius Ctr Hlth Sci & Primary Care, NL-3508 AB Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Dept Epidemiol, NL-3508 AB Utrecht, Netherlands
关键词
Cardiotocography; fetal electrocardiogram; inter- and intra-observer agreement; ST analysis; CLINICAL-PRACTICE; CARDIOTOCOGRAPHY; TRIAL; BIRTH; BLOOD;
D O I
10.1111/j.1471-0528.2008.02092.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The objective of this study was to quantify inter- and intra-observer agreement on classification of the intrapartum cardiotocogram (CTG) and decision to intervene following STAN guidelines. A prospective, observational study. Obstetrics Department of a tertiary referral hospital. STAN recordings of 73 women after 36 weeks of gestation with a high-risk pregnancy, induced or oxytocin-augmented labour, meconium-stained amniotic fluid or epidural analgesia. Six observers classified 73 STAN recordings and decided if and when they would suggest an intervention. Proportions of specific agreement (P(s)) and kappa values (K) were calculated. Agreement upon classification of the intrapartum CTG and decision to perform an intervention. Agreement for classification of a normal and a (pre)terminal CTG was good (P(s) range 0.50-0.84), but poor for the intermediary and abnormal CTG (P(s) range 0.34-0.56). Agreement on the decision to intervene was higher, especially on the decision to perform 'no intervention' (P(s) range 0.76-0.94). Overall inter-observer agreement on the decision to intervene was considered moderate in five of six observer combinations according to the kappa (K range 0.42-0.73). Intra-observer agreement for CTG classification and decision to intervene was moderate (K range 0.52-0.67 and 0.61-0.75). Inter-observer agreement on classification of the intrapartum CTG is poor, but addition of information regarding fetal electrocardiogram, especially in case of intermediary or abnormal CTG traces, results in a more standardised decision to intervene.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 50 条
  • [21] Inter- and Intra-Observer Variations in the Delineation of Lesions in Mammograms
    Buelow, Thomas
    Heese, Harald S.
    Grewer, Ruediger
    Kutra, Dominik
    Wiemker, Rafael
    MEDICAL IMAGING 2015: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2015, 9416
  • [22] An inter- and intra-observer test of the computer program CRANID
    Lee, Matthew
    Gerdau-Radonic, Karina
    FORENSIC SCIENCE INTERNATIONAL, 2022, 337
  • [23] Inter- and intra-observer variability of glenoid track measurements
    Schneider, Adrian
    Hoy, Gregory A.
    Ek, Eugene T.
    Rotstein, Andrew H.
    Tate, Julie
    Taylor, David McD
    Evans, Matthew C.
    SWISS MEDICAL WEEKLY, 2017, 147 : 41S - 41S
  • [24] Inter- and intra-observer variation in the reporting of cervical smears
    Smith, JHF
    CYTOPATHOLOGY, 1997, 8 (01) : 68 - 69
  • [25] Visual diagnosis of pectus excavatum: An inter-observer and intra-observer agreement analysis
    Daemen, Jean H. T.
    de Loos, Erik R.
    Geraedts, Tessa C. M.
    van Veer, Hans
    Van Huijstee, Pieter Jan
    Elenbaas, Ted W. O.
    Hulsewe, Karel W. E.
    Vissers, Yvonne L. J.
    JOURNAL OF PEDIATRIC SURGERY, 2022, 57 (03) : 526 - 531
  • [26] The Pfirrmann classification of lumbar intervertebral disc degeneration: an independent inter- and intra-observer agreement assessment
    Julio Urrutia
    Pablo Besa
    Mauricio Campos
    Pablo Cikutovic
    Mario Cabezon
    Marcelo Molina
    Juan Pablo Cruz
    European Spine Journal, 2016, 25 : 2728 - 2733
  • [27] Reliability analysis of the Manchester Triage System: inter-observer and intra-observer agreement
    de Souza, Cristiane Chaves
    Machado Chianca, Tania Couto
    Cordeiro Junior, Welfane
    Paixao Rausch, Maria do Carmo
    Lana Nascimento, Gabriela Fontoura
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2018, 26
  • [28] The Pfirrmann classification of lumbar intervertebral disc degeneration: an independent inter- and intra-observer agreement assessment
    Urrutia, Julio
    Besa, Pablo
    Campos, Mauricio
    Cikutovic, Pablo
    Cabezon, Mario
    Molina, Marcelo
    Pablo Cruz, Juan
    EUROPEAN SPINE JOURNAL, 2016, 25 (09) : 2728 - 2733
  • [29] Inter- and Intra-observer agreement of Newly Developed Software for Retinal Arteriolar Focal Narrowing Quantification
    Bhuiyan, Alauddin
    Roy, Pallab
    Hussain, Akter
    Lee, Kim
    Lamoureux, Ecosse Luc
    Wong, Tien Yin
    Storey, Elsdon
    Kanagasingam, Yogesan
    Kotagiri, Rao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [30] Retrospective analysis of tracheal hypoplasia in brachycephalic and non-brachycephalic dogs: Inter- and intra-observer agreement of measurements
    Sevcikova, Marieta K.
    Sevcik, Karol
    Figurova, Maria
    Agyagosova-Valencakova, Alexandra
    Hluchy, Marian
    Hornakova, L'ubica
    Lapsanska, Maria
    Kerekes, Zoltan
    Zert, Zdenek
    ACTA VETERINARIA HUNGARICA, 2022, 70 (03) : 192 - 200