In vivo estimation of the flow-driven adiabatic inversion efficiency for continuous arterial spin labeling: A method using phase contrast magnetic resonance angiography

被引:18
|
作者
O'Gorman, Ruth L.
Summers, Paul E.
Zelaya, Fernando O.
Williams, Steven C. R.
Alsop, David C.
Lythgoe, David J.
机构
[1] Kings Coll London, Inst Psychiat, Ctr Neuroimaging Sci, London SE5 8AF, England
[2] Kings Coll Hosp London, Dept Neuroimaging, London, England
[3] Kings Coll Hosp London, Dept Med Engn & Phys, London, England
[4] Univ Oxford, Dept Neuroradiol, Nuffield Dept Surg, Radcliffe Infirm, Oxford OX2 6HE, England
[5] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[6] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
adiabatic inversion efficiency; arterial spin labeling; perfusion; velocity mapping; magnetic resonance angiography;
D O I
10.1002/mrm.20864
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accurate quantification of perfusion with arterial spin labeling (ASL) requires consideration of a number of factors, including the efficiency of the inversion and control pulses used for spin labeling. In this study the effects of spin velocity on continuous ASL efficiency when using the amplitude modulated control strategy were investigated using simulations of the Bloch equations. The inversion efficiency was determined in vivo by combining the simulations with phase-contrast velocity mapping data acquired at the level of the tagging plane. Using this novel method, an average inversion efficiency of 69% was calculated for a group of 28 subjects, in good agreement with experimental data reported previously. There was, however, a large range in inversion efficiency measured across; the subject group (50-76%), indicating that the velocity dependence of the amplitude modulated control efficiency may introduce additional variability into the perfusion calculations if not properly taken into account.
引用
收藏
页码:1291 / 1297
页数:7
相关论文
共 50 条
  • [31] Skeletal Muscle Microvascular Flow in Progressive Peripheral Artery Disease Assessment With Continuous Arterial Spin-Labeling Perfusion Magnetic Resonance Imaging
    Wu, Wen-Chau
    Mohler, Emile
    Ratcliffe, Sarah J.
    Wehrli, Felix W.
    Detre, John A.
    Floyd, Thomas F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (25) : 2372 - 2377
  • [32] Evaluation of cerebral blood flow using multi-phase pseudo continuous arterial spin labeling at 3-tesla
    Sugimori, Hiroyuki
    Fujima, Noriyuki
    Suzuki, Yuriko
    Hamaguchi, Hiroyuki
    Sakata, Motomichi
    Kudo, Kohsuke
    MAGNETIC RESONANCE IMAGING, 2015, 33 (10) : 1338 - 1344
  • [33] Examination of Blood Flow in Rat Brain Vessels using Fluid Dynamic Simulation and Phase Contrast Magnetic Resonance Angiography
    Lehmpfuhl, Monika C.
    Hao Chongyang
    Hess, Andreas
    Gaudnek, M. Andre
    Sibila, Michael
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 4, 2010, : 299 - +
  • [34] Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging
    Leonard Sunwoo
    Chul-Ho Sohn
    Jong Young Lee
    Kyung Sik Yi
    Tae Jin Yun
    Seung Hong Choi
    Young Dae Cho
    Ji-hoon Kim
    Sun-Won Park
    Moon Hee Han
    Sun Ha Paek
    Yong Hwy Kim
    Jin Wook Kim
    Hyun-Tai Chung
    Dong Gyu Kim
    Neuroradiology, 2015, 57 : 775 - 782
  • [35] Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging
    Sunwoo, Leonard
    Sohn, Chul-Ho
    Lee, Jong Young
    Yi, Kyung Sik
    Yun, Tae Jin
    Choi, Seung Hong
    Cho, Young Dae
    Kim, Ji-hoon
    Park, Sun-Won
    Han, Moon Hee
    Paek, Sun Ha
    Kim, Yong Hwy
    Kim, Jin Wook
    Chung, Hyun-Tai
    Kim, Dong Gyu
    NEURORADIOLOGY, 2015, 57 (08) : 775 - 782
  • [36] Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: Initial experience
    Miyazaki, Mitsue
    Zhou, Xiangzhi
    Hoshino, Tsutomu
    Yokoyama, Kenichi
    Ishimura, Rieko
    Nitatori, Toshiaki
    MICROVASCULAR RESEARCH, 2015, 98 : 94 - 101
  • [37] Non contrast, Pseudo-Continuous Arterial Spin Labeling and Accelerated 3-Dimensional Radial Acquisition Intracranial 3-Dimensional Magnetic Resonance Angiography for the Detection and Classification of Intracranial Arteriovenous Shunts
    Schubert, Tilman
    Clark, Zachary
    Sandoval-Garcia, Carolina
    Zea, Ryan
    Wieben, Oliver
    Wu, Huimin
    Turski, Patrick A.
    Johnson, Kevin M.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (02) : 80 - 86
  • [38] Pseudo-continuous arterial spin labeling at 7 T for human brain: Estimation and correction for off-resonance effects using a Prescan
    Luh, Wen-Ming
    Talagala, S. Lalith
    Li, Tie-Qiang
    Bandettini, Peter A.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 402 - 410
  • [39] A Novel Application of Four-dimensional Magnetic Resonance Angiography Using Arterial Spin Labeling for Assessment of Postoperative Cerebral Hemodynamic Changes in Moyamoya Disease
    Uchino, Haruto
    Ito, Masaki
    Kazumata, Ken
    Houkin, Kiyohiro
    STROKE, 2016, 47
  • [40] Accurate and robust segmentation of cerebral vasculature on four-dimensional arterial spin labeling magnetic resonance angiography using machine-learning approach
    Liao, Weibin
    Shi, Gen
    Lv, Yi
    Liu, Lixin
    Tang, Xihe
    Jin, Yongjian
    Ning, Zihan
    Zhao, Xihai
    Li, Xuesong
    Chen, Zhensen
    MAGNETIC RESONANCE IMAGING, 2024, 110 : 86 - 95