Mn(II) based T1 and T2 potential MRI contrast agent appended with tryptamine: Recognition moiety for Aβ-plaques

被引:14
|
作者
Rastogi, Neeraj [1 ]
Tyagi, Nidhi [2 ]
Singh, Ovender [2 ]
Kumar, B. S. Hemanth [3 ]
Singh, Udai P.
Ghosh, Kaushik [2 ]
Roy, Raja [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Ctr Biomed Res, Lucknow 226014, Uttar Pradesh, India
[2] IIT Roorkee, Dept Chem, Roorkee 247667, Uttarakhand, India
[3] INMAS, NMR Res Ctr, SK Mazumdar Marg, Delhi 110054, India
关键词
Seven coordinate manganese complexes; Magnetic resonance imaging; Alzhiemer's disease; Manganese(II) contrast agent; Dual mode; MONONUCLEAR IRON(III) COMPLEXES; NUCLEASE ACTIVITY; IN-VITRO; RELAXIVITY;
D O I
10.1016/j.jinorgbio.2017.08.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We report the synthesis and characterization of manganese(II) complexes having pentadentate ligands L-1 (2,6-bis(1-(2-phenyl-2-(pyridin-2-yl)hydrazono)ethyl)pyridine), L-2 (methyl 2,6-bis((E)-1-(2-phenyl-2-(pyridin-2yl)hydrazono)ethy-Disonicotinate), L-3 (N-(2-(1H-indol-3-yl)ethyl)-2,6-bisaE)-1-(2-phenyl-2-(pyridin2yl) hydrazono)ethyl)isonicotiamide) and their application as dual contrast agents for simultaneous T-1 and T-2 weighted magnetic resonance imaging. Single crystal analysis of all the complexes [(MnL1)-L-II, (MnL2)-L-II and (MnL3)-L-II] confirm the formation of novel seven-coordinate manganese complexes with an inner sphere water and per chlorate ion. The Magnetic Resonance Imaging (MRI) contrast agent [MnL2] was further modified by incorporating tryptamine as a binding moiety specific to Amyloid Beta-fibrils (A beta-fibrils) in Alzhiemer's disease (AD) and it's in vitro evaluation for specific binding with All-fibrils indicated as a bio-marker of AD.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [31] Motion correction of multi-contrast images applied to T1 and T2 quantification in cardiac MRI
    Anne Menini
    Glenn S. Slavin
    Jeffrey A. Stainsby
    Pauline Ferry
    Jacques Felblinger
    Freddy Odille
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 1 - 12
  • [32] Hydrogels Incorporating GdDOTA: Towards Highly Efficient Dual T1/T2 MRI Contrast Agents
    Courant, Thomas
    Roullin, Valerie Gaelle
    Cadiou, Cyril
    Callewaert, Maite
    Andry, Marie Christine
    Portefaix, Christophe
    Hoeffel, Christine
    de Goltstein, Marie Christine
    Port, Marc
    Laurent, Sophie
    Vander Elst, Luce
    Muller, Robert
    Molinari, Michael
    Chuburu, Francoise
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (36) : 9119 - 9122
  • [33] Motion correction of multi-contrast images applied to T1 and T2 quantification in cardiac MRI
    Menini, Anne
    Slavin, Glenn S.
    Stainsby, Jeffrey A.
    Ferry, Pauline
    Felblinger, Jacques
    Odille, Freddy
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (01) : 1 - 12
  • [34] Nanosized T1 MRI Contrast Agent Based on a Polyamidoamine as Multidentate Gd Ligand
    Arosio, Paolo
    Cicolari, Davide
    Manfredi, Amedea
    Orsini, Francesco
    Lascialfari, Alessandro
    Ranucci, Elisabetta
    Ferruti, Paolo
    Maggioni, Daniela
    MOLECULES, 2022, 27 (01):
  • [35] T1/T2 ratio from 3T MRI improves multiple sclerosis cortical lesion contrast
    Manning, Abigail R.
    Beck, Erin S.
    Schindler, Matthew K.
    Nair, Govind
    Clark, Kelly A.
    Parvathaneni, Prasanna
    Reich, Daniel S.
    Shinohara, Russell T.
    Solomon, Andrew J.
    JOURNAL OF NEUROIMAGING, 2023, 33 (03) : 434 - 445
  • [36] Activatable T1 and T2 Magnetic Resonance Imaging Contrast Agents
    Chuqiao Tu
    Elizabeth A. Osborne
    Angelique Y. Louie
    Annals of Biomedical Engineering, 2011, 39 : 1335 - 1348
  • [37] Iterative Reconstruction of SPECT Brain with Priors Based On MRI T1 and T2 Image
    Gu, Q.
    Bowsher, J.
    Truong, T.
    Chen, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 2983 - 2983
  • [38] Evaluation of renal quantitative T2*changes on MRI following administration of ferumoxytol as a T2*contrast agent
    Hedgire, Sandeep S.
    McDermott, Shaunagh
    Wojtkiewicz, Gregory R.
    Abtahi, Seyed Mahdi
    Harisinghani, Mukesh
    Gaglia, Jason L.
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 : 2101 - 2107
  • [39] VSION as high field MRI T1 contrast agent: evidence of their potential as positive contrast agent for magnetic resonance angiography
    Vangijzegem, T.
    Stanicki, D.
    Boutry, S.
    Paternoster, Q.
    Vander Elst, L.
    Muller, R. N.
    Laurent, S.
    NANOTECHNOLOGY, 2018, 29 (26)
  • [40] T1 AND T2 OF FERRITIN AT DIFFERENT FIELD STRENGTHS - EFFECT ON MRI
    VYMAZAL, J
    BROOKS, RA
    ZAK, O
    MCRILL, C
    SHEN, C
    DICHIRO, G
    MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) : 368 - 374