Second External Quality Assurance Study for the Serological Diagnosis of Hantaviruses in Europe

被引:12
|
作者
Escadafal, Camille [1 ,2 ]
Avsic-Zupanc, Tatjana [3 ]
Vapalahti, Olli [4 ]
Niklasson, Bo [5 ,6 ]
Teichmann, Anette [1 ]
Niedrig, Matthias [1 ]
Donoso-Mantke, Oliver [1 ]
机构
[1] Robert Koch Inst, ZBS 1, Berlin, Germany
[2] European Ctr Dis Prevent & Control ECDC, European Publ Hlth Microbiol Training Programme E, Solna, Sweden
[3] Univ Ljubljana, Inst Microbiol & Immunol, Fac Med, Ljubljana, Slovenia
[4] Univ Helsinki, Dept Virol, Haartman Inst, Helsinki, Finland
[5] Apodemus AB, Stockholm, Sweden
[6] Uppsala Univ, Dept Med Cell Biol, Uppsala, Sweden
来源
PLOS NEGLECTED TROPICAL DISEASES | 2012年 / 6卷 / 04期
关键词
INFECTIONS; ACCURACY; PUUMALA;
D O I
10.1371/journal.pntd.0001607
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Hantaviruses are endemic throughout the world and hosted by rodents and insectivores. Two human zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome (HPS), are caused by hantaviruses and case fatality rates have reached 12% for HFRS and 50% for HPS in some outbreaks. Symptomatic hantavirus infections in Europe are summarised as HFRS mainly due to Puumala, Dobrava-Belgrade and Saaremaa virus. While HFRS has an overall low incidence in Europe, the number of cases varies from 100 per year in all Eastern and Southern Europe up to 1,000 per year only in Finland. To assess the quality of hantavirus diagnostics, the European Network for the Diagnostics of 'Imported'' Viral Diseases (ENIVD) organised a first external quality assurance (EQA) in 2002. The purpose of this second EQA study is to collect updated information on the efficiency and accurateness of hantavirus serological methods applied by expert laboratories. A serum panel of 14 samples was sent to 28 participants in Europe of which 27 sent results. Performance in hantavirus diagnosis varied not only on the method used but also on the laboratories and the subclass of antibodies tested. Commercial and in-house assays performed almost equally. Enzyme immunoassays were mainly used but did not show the best performances while immunoblot assays were the less employed and showed overall better performances. IgM antibodies were not detected in 61% of the positive IgM samples and IgM detection was not performed by 7% of the laboratories indicating a risk of overlooking acute infections in patients. Uneven performances using the same method is indicating that there is still a need for improving testing conditions and standardizing protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Reliability study of cholesterol methods in an external quality assurance program
    Raymondo, S
    Mastropierro, M
    Scholnik, C
    Cladera, M
    Piana, AM
    CLINICAL CHEMISTRY, 2004, 50 (06) : A188 - A188
  • [32] Integrating quality control and external quality assurance
    Badrick, Tony
    CLINICAL BIOCHEMISTRY, 2021, 95 : 15 - 27
  • [33] External quality assurance studies for the serological and PCR diagnostics of tick-borne encephalitis virus infections
    Mantke, Oliver Donoso
    Aberle, Stephan W.
    Avsic-Zupanc, Tatjana
    Labuda, Milan
    Ferenczi, Emoeke
    Rozentale, Baiba
    Niedrig, Matthias
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 333 - 335
  • [34] EQA - The management of external quality assurance
    Sandle, LN
    JOURNAL OF CLINICAL PATHOLOGY, 2005, 58 (02) : 141 - 144
  • [35] External quality assurance in the era of standardization
    Theodorsson, Elvar
    Meijer, Piet
    Badrick, Tony
    CLINICA CHIMICA ACTA, 2024, 557
  • [36] EXTERNAL ANALYTICAL QUALITY ASSURANCE FOR PROTEINS
    PETERSEN, PH
    BLAABJERG, O
    IRJALA, K
    ICEN, A
    BJORO, K
    UPSALA JOURNAL OF MEDICAL SCIENCES, 1993, 98 (03) : 241 - 258
  • [37] External quality assurance - a personal view
    Middle, J
    ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 : 112 - 113
  • [38] External quality assurance - a personal view
    Thurlow, V
    ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 : 229 - 230
  • [39] EXTERNAL QUALITY ASSURANCE: THE AUSTRALIAN EXPERIENCE
    Ross, J.
    Cummings, M. C.
    ACTA CYTOLOGICA, 2010, 54 (03) : 396 - 396
  • [40] External Quality Assurance for Heparin Monitoring
    Bonar, Roslyn A.
    Favaloro, Emmanuel J.
    Marsden, Katherine
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2012, 38 (06): : 632 - 639