Application of two-wavelength optical heterodyne alignment system in XS-1

被引:9
|
作者
Mitsui, S [1 ]
Taguchi, T [1 ]
Kikuchi, Y [1 ]
Aoyama, H [1 ]
Matsui, Y [1 ]
Suzuki, M [1 ]
Haga, T [1 ]
Fukuda, M [1 ]
Morita, H [1 ]
Shibayama, A [1 ]
机构
[1] NTT Corp, Telecommun Energy Labs, Assoc Super Adv Elect Technol, Super Fine SR Lithog Lab, Atsugi, Kanagawa 2430198, Japan
关键词
proximity x-ray lithography; stepper; two-wavelength optical heterodyne alignment; alignment accuracy; systematic alignment offset; processed wafers; wafer-induced shift;
D O I
10.1117/12.351120
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents the alignment performance of the two-wavelength optical heterodyne alignment system in the x-ray stepper XS-1. The alignment accuracy (mean+3 sigma) obtained by the double-exposure method with a single mask and a Si trench wafer was better than 20 mn. The dependence of the alignment accuracy on Si trench depth indicated that the two wavelengths compliment each other and ensure a 3 sigma of less than 20 mn. The alignment capabilities for other processed test wafers were also investigated by mix-and-match exposure. For etched SiO2, and poly-Si film on a Si trench, an accuracy below 20 nm (3 sigma) was obtained. For AlSiCu film sputtered on etched SiO2, there appeared systematic alignment offsets (i.e., die shift and rotation errors) depended on die position, which are thought to be due to a wafer-induced shift. The systematic offset errors were eliminated by the use of a send-ahead wafer and corrections for individual offsets on each die, and thus the alignment accuracy was improved to 20-40 nm (3 sigma) for each alignment axis. The two-wavelength heterodyne alignment system of the XS-1 has sufficient potential for 130-nm lithography and below.
引用
收藏
页码:455 / 465
页数:7
相关论文
共 50 条
  • [21] Full-field heterodyne phase shifting two-wavelength interferometry surface testing technologies
    Fan G.
    Li Y.
    Zhang W.
    Wu Z.
    Lv T.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (09):
  • [22] Time-multiplex two-wavelength heterodyne interferometer with frequency-ramped laser diodes
    Onodera, R
    Ishii, Y
    OPTICS COMMUNICATIONS, 1999, 167 (1-6) : 47 - 51
  • [23] Time-multiplex two-wavelength heterodyne interferometer with frequency-ramped laser diodes
    Onodera, Ribun
    Ishii, Yukihiro
    Optics Communications, 1999, 167 (01): : 47 - 51
  • [24] Locking of two widely separated cw lasers through a two-wavelength delayed self-heterodyne interferometer
    Kuse, N.
    Fermann, M. E.
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,
  • [25] Two-wavelength ghost imaging with two-lens system in atmosphere
    Qiu, Yunli
    She, Weilong
    JOURNAL OF MODERN OPTICS, 2014, 61 (06) : 487 - 494
  • [27] Study on two-wavelength laser ranging system and its accuracy
    Zhong, Shangyuan
    Cheng, Ping
    1600, (22):
  • [28] Application and Evaluation of a Two-Wavelength Scintillometry System for Operation in a Complex Shallow Boreal-Forested Valley
    Isabelle, Pierre-Erik
    Nadeau, Daniel F.
    Perelet, Alexei O.
    Pardyjak, Eric R.
    Rousseau, Alain N.
    Anctil, Francois
    BOUNDARY-LAYER METEOROLOGY, 2020, 174 (03) : 341 - 370
  • [29] Application and Evaluation of a Two-Wavelength Scintillometry System for Operation in a Complex Shallow Boreal-Forested Valley
    Pierre-Erik Isabelle
    Daniel F. Nadeau
    Alexei O. Perelet
    Eric R. Pardyjak
    Alain N. Rousseau
    François Anctil
    Boundary-Layer Meteorology, 2020, 174 : 341 - 370
  • [30] A two-wavelength optical method for the high combustion temperature measurement of solid propellant
    Xu, Chao-Qi
    He, Guo-Qiang
    Liu, Pei-Jin
    Li, Peng-Fei
    Guti Huojian Jishu/Journal of Solid Rocket Technology, 2010, 33 (05): : 594 - 598