Longitudinal validity of spirometers -: a challenge in longitudinal studies

被引:0
|
作者
Künzli, N
Kuna-Dibbert, B
Keidel, D
Keller, R
Brändli, O
Schindler, C
Schweinzer, KM
Leuenberger, P
Ackermann-Liebrich, U
机构
[1] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
[2] Univ Basel, Inst Social & Prevent Med, Basel, Switzerland
[3] Pulmonol Clin, Aarau, Switzerland
[4] Fed Off, Vienna, Austria
[5] Res Ctr Forests, Vienna, Austria
[6] Univ Lausanne Hosp, Serv Pulmonol, Lausanne, Switzerland
关键词
spirometer comparison; quality control; cohort studies; lung function measurements;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Question understudy: Pulmonary function testing (PFT) in longitudinal studies involves the repeated use of spirometers over long time periods. We assess the comparability of PFT results taken under biologic field conditions using thirteen certified devices of various technology and age. Comparability of measurements across devices and over time is relevant both in clinical and epidemiological research. Methods: Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1) and Forced Expiratory Flow 50% (FEF50) were compared before and after the data collection of the Swiss Study on Air Pollution and Lung Diseases in Adults (SAPALDIA) and the European Community Respiratory Health Survey (ECRHS) cohort studies. Three test series were conducted with 46, 50 and 56 volunteers using various combinations of spirometers to compare the eight flow-sensing spirometers (Sensormedics 2200) used in the SAPALDIA cross-sectional and follow-up, two new flow-sensing instruments (Sensormedics V-max) and three volume displacement spirometers (two Biomedin/Baires and one Sensormedics 2400). Results: The initial comparison (1999/2000) of eight Sensormedics 2200 and the follow-up comparison (2003) of the same devices revealed a maximal variation of up to 2.6% for FVC, 2.4% for FEV1 and 2.8% for FEF50 across devices with no indication of systematic differences between spirometers. Results were also reproducible between Biomedin, Sensormedics 2200 and 2400. The new generation of Sensormedics (V-max) gave systematically lower results. Conclusions: The study demonstrates the need to conduct spirometer comparison tests with humans. For follow-up studies we strongly recommend the use of the same spirometers.
引用
收藏
页码:503 / 508
页数:6
相关论文
共 50 条
  • [21] LONGITUDINAL-STUDIES
    GUNZBURG, HC
    BRITISH JOURNAL OF MENTAL SUBNORMALITY, 1990, 36 (71): : 76 - 76
  • [22] Publishing longitudinal studies
    Munk-Jorgensen, P
    NORDIC JOURNAL OF PSYCHIATRY, 2000, 54 : 2 - 2
  • [23] Longitudinal Predictive Validity of a Learning Potential Test
    de Beer, Marie
    JOURNAL OF PSYCHOLOGY IN AFRICA, 2010, 20 (02) : 225 - 231
  • [24] Longitudinal Change In OMNI RPE Validity In Youth
    Gammon, Catherine
    Pfeiffer, Karin A.
    Trost, Stewart G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 599 - 600
  • [25] INTERNAL AND EXTERNAL VALIDITY OF SIMPLE LONGITUDINAL DESIGNS
    LABOUVIE, EW
    BARTSCH, TW
    NESSELRO.JR
    BALTES, PB
    CHILD DEVELOPMENT, 1974, 45 (02) : 282 - 290
  • [26] Longitudinal validity of the hemophilia caregiver impact measure
    Carolyn E. Schwartz
    Jie Zhang
    Jun Su
    Quality of Life Research, 2019, 28 : 1979 - 1987
  • [27] Sluggish cognitive tempo: longitudinal stability and validity
    Vu, Alexander
    Thompson, Lee
    Willcutt, Erik
    Petrill, Stephen
    ADHD-ATTENTION DEFICIT AND HYPERACTIVITY DISORDERS, 2019, 11 (04) : 463 - 471
  • [28] ASSESSMENT-CENTER VALIDITY - LONGITUDINAL STUDY
    MITCHEL, JO
    JOURNAL OF APPLIED PSYCHOLOGY, 1975, 60 (05) : 573 - 579
  • [29] A longitudinal study on the temporal validity of software samples
    Carruthers, Juan Andres
    Diaz-Pace, Jorge Andres
    Irrazabal, Emanuel
    INFORMATION AND SOFTWARE TECHNOLOGY, 2024, 168
  • [30] Validity of longitudinal sections for determining the apical constriction
    Schell, S.
    Judenhofer, M. S.
    Mannheim, J. G.
    Huelber-J, M.
    Loest, C.
    Pichler, B. J.
    ElAyouti, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (07) : 706 - 712