Quantitative estimation of ultrasound beam intensities using infrared thermography-Experimental validation

被引:14
|
作者
Giridhar, Dushyanth [1 ]
Robinson, Ronald A. [1 ]
Liu, Yunbo [1 ]
Sliwa, Jack [3 ]
Zderic, Vesna [2 ]
Myers, Matthew R. [1 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] George Washington Univ, Dept Elect & Comp Engn, Washington, DC 20052 USA
[3] St Jude Med, AF Div, Sunnyvale, CA 94085 USA
来源
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA | 2012年 / 131卷 / 06期
关键词
FOCUSED ULTRASOUND; CALIBRATION;
D O I
10.1121/1.4711006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Infrared (IR) thermography is a technique that has the potential to rapidly and noninvasively determine the intensity fields of ultrasound transducers. In the work described here, IR temperature measurements were made in a tissue phantom sonicated with a high-intensity focused ultrasound (HIFU) transducer, and the intensity fields were determined using a previously published mathematical formulation relating intensity to temperature rise at a tissue/air interface. Intensity fields determined from the IR technique were compared with those derived from hydrophone measurements. Focal intensities and beam widths determined via the IR approach agreed with values derived from hydrophone measurements to within a relative difference of less than 10%, for a transducer with a gain of 30, and about 13% for a transducer with a gain of 60. At axial locations roughly 1 cm in front (pre-focal) and behind (post-focal) the focus, the agreement with hydrophones for the lower-gain transducer remained comparable to that in the focal plane. For the higher-gain transducer, the agreement with hydrophones at the pre-focal and post-focal locations was around 40%. [http://dx.doi.org/10.1121/1.4711006]
引用
收藏
页码:4283 / 4291
页数:9
相关论文
共 50 条
  • [21] Quantitative Evaluation of the Fracturing State of Crystalline Rocks Using Infrared Thermography
    Federico Franzosi
    Stefano Casiraghi
    Roberto Colombo
    Chiara Crippa
    Federico Agliardi
    Rock Mechanics and Rock Engineering, 2023, 56 : 6337 - 6355
  • [22] Measurement of turbulent heat transfer coefficients using infrared thermography near ambient conditions and its quantitative error estimation
    Inagaki, T
    Okamoto, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1999, 42 (02) : 275 - 283
  • [23] The effect of depth on the quantitative estimation of defect size using pulsed thermography
    Feng Tie
    Zhang Cunlin
    Feng Lichun
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [24] Crack detection in aluminum parts by using ultrasound-excited infrared thermography
    Guo, Xingwang
    Vavilov, Vladimir
    INFRARED PHYSICS & TECHNOLOGY, 2013, 61 : 149 - 156
  • [25] Thermo-mechanical modeling of polymer spur gears with experimental validation using high-speed infrared thermography
    Cerne, B.
    Petkovsek, M.
    Duhovnik, J.
    Tavcar, J.
    MECHANISM AND MACHINE THEORY, 2020, 146
  • [28] DETECTION OF CAROTID OCCLUSIVE DISEASE USING RADIOISOTOPES, INFRARED THERMOGRAPHY, AND DOPPLER ULTRASOUND
    RAND, E
    DISEASES OF THE CHEST, 1969, 56 (03): : 265 - &
  • [29] Experimental Study on Detection of Deterioration in Concrete Using Infrared Thermography Technique
    Huh, Jungwon
    Quang Huy Tran
    Lee, Jong-Han
    Han, DongYeob
    Ahn, Jin-Hee
    Yim, Solomon
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2016, 2016
  • [30] Vibration characteristics measurement of beam-like structures using infrared thermography
    Talai, S. M.
    Desai, D. A.
    Heyns, P. S.
    INFRARED PHYSICS & TECHNOLOGY, 2016, 79 : 17 - 24