3D high-resolution anorectal manometry in patients with perianal fistulas: comparison with 3D-anal ultrasound

被引:5
|
作者
Felt-Bersma, Richelle J. F. [1 ,2 ]
Vlietstra, Maarten S. [1 ]
Vollebregt, Paul F. [1 ]
Han-Geurts, Ingrid J. M. [2 ]
Rempe-Sorm, Vera [2 ]
Mijnsbrugge, Grietje J. H. Vander [2 ]
Molenaar, Charlotte B. H. [2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Gastroenterol & Hepatol, Amsterdam, Netherlands
[2] Proctos Clin, Bilthoven, Netherlands
来源
BMC GASTROENTEROLOGY | 2018年 / 18卷
关键词
Anorectal manometry; 3D-HRAM; Endoanal ultrasound; 3D-EUS; Anal fistula; 3-DIMENSIONAL ENDOANAL ULTRASOUND; SPHINCTER DEFECTS; ANAL FISTULA; FECAL INCONTINENCE; NORMAL VALUES; IN-ANO; PRESSURE; CONSENSUS; ACCURACY; SURGERY;
D O I
10.1186/s12876-018-0770-6
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Perianal fistula surgery can damage the anal sphincters which may cause faecal incontinence. By measuring regional pressures, 3D-HRAM potentially provides better guidance for surgical strategy in patients with perianal fistulas. The aim was to measure regional anal pressures with 3D-HRAM and to compare these with 3D-EUS findings in patients with perianal fistulas. Methods: Consecutive patients with active perianal fistulas who underwent both 3D-EUS and 3D-HRAM at a clinic specialised in proctology were included. A group of 30 patients without fistulas served as controls. Data regarding demographics, complaints, previous perianal surgical procedures and obstetric history were collected. The mean and regional anal pressures were measured with 3D-HRAM. Fistula tract areas detected with 3D-EUS were analysed with 3D-HRAM by visual coding and the regional pressures of the corresponding and surrounding area of the fistula tract areas were measured. The study was granted by the VUmc Medical Ethical Committee. Results: Forty patients (21 males, mean age 47) were included. Four patients had a primary fistula, 19 were previously treated with a seton/abscess drainage and 17 had a recurrence after previously performed fistula surgery. On 3D-HRAM, 24 (60%) fistula tract areas were good and 8 (20%) moderately visible. All but 7 (18%) patients had normal mean resting pressures. The mean resting pressure of the fistula tract area was significantly lower compared to the surrounding area (47 vs. 76 mmHg; p < 0.0001). Only 2 (5%) patients had a regional mean resting pressure < 10 mmHg of the fistula tract area. Using a Delta mean resting pressure >= 30 mmHg difference between fistula tract area and non-fistula tract area as alternative cut-off, 21 (53%) patients were identified. In 6 patients 3D-HRAM was repeated after surgery: a local pressure drop was detected in one patient after fistulotomy with increased complaints of faecal incontinence. Conclusions: Profound local anal pressure drops are found in the fistula tract areas in patients normal mean resting pressures. Fistulotomy may affect local sphincter pressure. This might influence surgical decision making in future.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] High-resolution Anorectal Manometry and Anal Endosonographic Findings in the Evaluation of Fecal Incontinence
    Lee, Tae Hee
    Lee, Joon Seong
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 18 (04) : 450 - 451
  • [32] High-resolution 3D printing in seconds
    Darkes-Burkey, Cameron
    Shepherd, Robert F.
    NATURE, 2020, 588 (7839) : 594 - 595
  • [33] 3D High-Resolution Geophysical Surveys
    Sack, Peter
    Haugland, Tor
    SEA TECHNOLOGY, 2012, 53 (10) : 23 - +
  • [34] 3D mapping with high-resolution images
    Toutin, T
    Chénier, R
    Carbonneau, Y
    Alcaïde, N
    GEOINFORMATION FOR EUROPEAN-WIDE INTEGRATION, 2003, : 121 - 125
  • [35] High-resolution 3D survey of artworks
    Fontana, R
    Gambino, MC
    Mazzotta, C
    Greco, M
    Pampaloni, E
    Pezzati, L
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 719 - 726
  • [36] High-resolution 3D imaging of tissue
    Burgess, Sean A.
    Yuan, Baohong
    Radosevich, Andrew J.
    Bouchard, Mathew B.
    Hillman, Elizabeth M. C.
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 5 - 6
  • [37] High-resolution 3D genome characterization
    Burgess D.
    Nature Reviews Genetics, 2021, 22 (8) : 481 - 481
  • [38] High-resolution 3D mapping of loops
    Linda Koch
    Nature Reviews Genetics, 2015, 16 (2) : 68 - 68
  • [39] High-Resolution 3D Printing for Electronics
    Park, Young-Geun
    Yun, Insik
    Chung, Won Gi
    Park, Wonjung
    Lee, Dong Ha
    Park, Jang-Ung
    ADVANCED SCIENCE, 2022, 9 (08)
  • [40] High-resolution 3D printing in seconds
    Cameron Darkes-Burkey
    Robert F. Shepherd
    Nature, 2020, 588 : 594 - 595