Real-time estimation of paracellular permeability of cerebral endothelial cells by capacitance sensor array

被引:12
|
作者
Jo, Dong Hyun [1 ,2 ]
Lee, Rimi [3 ]
Kim, Jin Hyoung [1 ]
Jun, Hyoung Oh [1 ]
Lee, Tae Geol [3 ]
Kim, Jeong Hun [1 ,2 ,4 ]
机构
[1] Seoul Natl Univ Hosp, Clin Res Inst, Fight Angiogenesis Related Blindness FARB Lab, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul, South Korea
[3] Korea Res Inst Stand & Sci Daejeon, Cytr Nanobio Measurement, Taejon, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
来源
SCIENTIFIC REPORTS | 2015年 / 5卷
关键词
DIELECTRIC-SPECTROSCOPY; BARRIER; DISRUPTION; FREQUENCY; TISSUE;
D O I
10.1038/srep11014
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Vascular integrity is important in maintaining homeostasis of brain microenvironments. In various brain diseases including Alzheimer's disease, stroke, and multiple sclerosis, increased paracellular permeability due to breakdown of blood-brain barrier is linked with initiation and progression of pathological conditions. We developed a capacitance sensor array to monitor dielectric responses of cerebral endothelial cell monolayer, which could be utilized to evaluate the integrity of brain microvasculature. Our system measured real-time capacitance values which demonstrated frequencyand time-dependent variations. With the measurement of capacitance at the frequency of 100 Hz, we could differentiate the effects of vascular endothelial growth factor (VEGF), a representative permeability-inducing factor, on endothelial cells and quantitatively analyse the normalized values. Interestingly, we showed differential capacitance values according to the status of endothelial cell monolayer, confluent or sparse, evidencing that the integrity of monolayer was associated with capacitance values. Another notable feature was that we could evaluate the expression of molecules in samples in our system with the reference of real-time capacitance values. We suggest that this dielectric spectroscopy system could be successfully implanted as a novel in vitro assay in the investigation of the roles of paracellular permeability in various brain diseases.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Real-time monitoring sensor system for fiber bragg grating array
    Liu, Shengchun
    Yu, Youlong
    Zhang, Jintao
    Chen, Xiangfei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2007, 19 (17-20) : 1493 - 1495
  • [32] Claudin expression and paracellular permeability in cultured rabbit corneal endothelial cells (rce)
    Kuang, K
    Ma, L
    Sanchez, J
    Fischbarg, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [33] Claudia expression and paracellular permeability in cultured rabbit corneal endothelial cells (rce)
    Kuang, K
    Ma, L
    Sanchez, J
    Fischbarg, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U402 - U402
  • [34] TIGHT JUNCTIONS AND PARACELLULAR PERMEABILITY IN CULTURED BOVINE CORNEAL ENDOTHELIAL-CELLS
    NOSKE, W
    LEVARLET, B
    KREUSEL, KM
    FROMM, M
    HIRSCH, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (10) : 608 - 613
  • [35] Real-time confocal imaging of caveolae trafficking in endothelial cells
    Husain, YS
    Vogel, SM
    Malik, AB
    Minshall, RD
    FASEB JOURNAL, 2006, 20 (05): : A843 - A844
  • [36] Control of flow in resin transfer molding with real-time preform permeability estimation
    Nielsen, DR
    Pitchumani, R
    POLYMER COMPOSITES, 2002, 23 (06) : 1087 - 1110
  • [37] Real-Time Error Estimation for Real-Time Motion Prediction
    Moore, D.
    Sawant, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3711 - 3711
  • [38] Wireless sensor network based on a chemocapacitive sensor array for the real-time monitoring of industrial pollutants
    Oikonomou, P.
    Botsialas, A.
    Olziersky, A.
    Stratakos, I.
    Katsikas, S.
    Dimas, D.
    Sotiropoulos, G.
    Goustouridis, D.
    Raptis, I.
    Sanopoulou, M.
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 564 - 567
  • [39] REAL-TIME AND ROBUST ESTIMATION OF BIODIESEL BLENDS USING NOX SENSOR
    Mirheidari, S.
    Franchek, M. A.
    Grigoriadis, K. M.
    Mohammadpour, J.
    Wang, Y. Y.
    Haskara, I.
    PROCEEDINGS OF THE ASME DYNAMIC SYSTEMS AND CONTROL CONFERENCE AND BATH/ASME SYMPOSIUM ON FLUID POWER AND MOTION CONTROL (DSCC 2011), VOL 1, 2012, : 891 - 898
  • [40] Robust and real-time egomotion estimation using a compound omnidirectional sensor
    Thanh, Trung Ngo
    Nagahara, Hajime
    Sagawa, Ryusuke
    Mukaigawa, Yasuhiro
    Yachida, Masahiko
    Yagi, Yasushi
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, : 492 - 497