Real-time estimation of paracellular permeability of cerebral endothelial cells by capacitance sensor array

被引:12
|
作者
Jo, Dong Hyun [1 ,2 ]
Lee, Rimi [3 ]
Kim, Jin Hyoung [1 ]
Jun, Hyoung Oh [1 ]
Lee, Tae Geol [3 ]
Kim, Jeong Hun [1 ,2 ,4 ]
机构
[1] Seoul Natl Univ Hosp, Clin Res Inst, Fight Angiogenesis Related Blindness FARB Lab, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul, South Korea
[3] Korea Res Inst Stand & Sci Daejeon, Cytr Nanobio Measurement, Taejon, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
来源
SCIENTIFIC REPORTS | 2015年 / 5卷
关键词
DIELECTRIC-SPECTROSCOPY; BARRIER; DISRUPTION; FREQUENCY; TISSUE;
D O I
10.1038/srep11014
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Vascular integrity is important in maintaining homeostasis of brain microenvironments. In various brain diseases including Alzheimer's disease, stroke, and multiple sclerosis, increased paracellular permeability due to breakdown of blood-brain barrier is linked with initiation and progression of pathological conditions. We developed a capacitance sensor array to monitor dielectric responses of cerebral endothelial cell monolayer, which could be utilized to evaluate the integrity of brain microvasculature. Our system measured real-time capacitance values which demonstrated frequencyand time-dependent variations. With the measurement of capacitance at the frequency of 100 Hz, we could differentiate the effects of vascular endothelial growth factor (VEGF), a representative permeability-inducing factor, on endothelial cells and quantitatively analyse the normalized values. Interestingly, we showed differential capacitance values according to the status of endothelial cell monolayer, confluent or sparse, evidencing that the integrity of monolayer was associated with capacitance values. Another notable feature was that we could evaluate the expression of molecules in samples in our system with the reference of real-time capacitance values. We suggest that this dielectric spectroscopy system could be successfully implanted as a novel in vitro assay in the investigation of the roles of paracellular permeability in various brain diseases.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Real-time estimation of paracellular permeability of cerebral endothelial cells by capacitance sensor array
    Dong Hyun Jo
    Rimi Lee
    Jin Hyoung Kim
    Hyoung Oh Jun
    Tae Geol Lee
    Jeong Hun Kim
    Scientific Reports, 5
  • [2] Real-time monitoring of adipocyte differentiation using a capacitance sensor array
    Lee, Rimi
    Jung, Inji
    Park, Miyoung
    Ha, Hunjoo
    Yoo, Kyung Hwa
    LAB ON A CHIP, 2013, 13 (17) : 3410 - 3416
  • [3] High Resolution Capacitance Sensor Array for Real-time Monitoring of Cell Viability
    Naviasky, Emily
    Datta-Chaudhuri, Timir
    Abshire, Pamela
    2014 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2014, : 634 - 637
  • [4] Real-Time Measurements of Cell Proliferation Using a Lab-on-CMOS Capacitance Sensor Array
    Senevirathna, Bathiya Prashan
    Lu, Sheung
    Dandin, Marc P.
    Basile, John
    Smela, Elisabeth
    Abshire, Pamela A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (03) : 510 - 520
  • [5] Real-Time Cell Viability Measurements Using Lab-on-CMOS-Capacitance Sensor Array
    Dasgupta, Prithwish
    Nielsen, Kyle
    Abshire, Pamela
    Lu, Sheung
    2024 IEEE 67TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, MWSCAS 2024, 2024, : 1305 - 1308
  • [6] A Novel Real-Time Capacitance Estimation Methodology for Battery-Less Wireless Sensor Systems
    Kim, Hwa Soo
    Sivaramakrishnan, Shyam
    Sezen, A. Serdar
    Rajamani, Rajesh
    IEEE SENSORS JOURNAL, 2010, 10 (10) : 1647 - 1657
  • [7] Rotational Angle Estimation Using an Acceleration Sensor Array and Real-Time Detection Algorithm
    Kim, Byung Kook
    Moon, Hyowon
    Jang, Minsu
    Kim, Jinseok
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (12) : 13883 - 13892
  • [8] A SMART PROCESSOR ARRAY SENSOR FOR REAL-TIME TRACKING
    COQUELET, C
    DEVOS, F
    GARDA, P
    ONDE ELECTRIQUE, 1988, 68 (06): : 82 - 85
  • [9] Live Demonstration: CMOS Capacitive Sensor Array for Real-time Analyses of Living Cells
    Nabovati, Ghazal
    Ghafar-Zadeh, Ebrahim
    Letourneau, Antoine
    Sawan, Mohamad
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 2374 - 2374
  • [10] In-line capacitance sensor for real-time water absorption measurements
    Nurge, Mark A.
    Perusich, Stephen A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (01) : 105 - 111