Active and passive measurements of radon diffusion coefficient from building construction materials

被引:27
|
作者
Kumar, Amit [1 ]
Chauhan, R. P. [1 ]
机构
[1] Natl Inst Technol, Dept Phys, Kurukshetra 136119, Haryana, India
关键词
Radon diffusion coefficient; Porosity; Scintillation radon monitor; Building materials; TRACK DETECTORS; INDOOR RADON; SOIL; MEMBRANES; BARRIER; SAMPLES; RATES; ASH;
D O I
10.1007/s12665-013-2951-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The gaseous state and chemical inert behavior of radon make it important tracer for the radon transport study through the building materials. The radon resistant property of building construction materials is important parameter to control the indoor radon levels in living and workplaces. The materials with higher radium content can be made less severe by the use of some building materials of low diffusion coefficient and diffusion length. This makes the study of radon diffusion through building material more important along with the study of exhalation and radioactivity content. Keeping this in mind the radon diffusion study was carried out through different building construction materials used for wall and floor by active and passive techniques. The diffusion coefficient from these building materials measured by passive methods varied from (0.9 +/- A 0.5) x 10(-7) to (22.95 +/- A 13.19) x 10(-6) m(2)s(-1) and radon diffusion length varied from 0.21 to 3.31 m for cement, soil, sand, wall putty and plaster of Paris (POP) etc. The radon diffusion coefficient measured by active technique varied from 1.93 x 10(-10) to 1.36 x 10(-7) m(2)s(-1) for samples with definite geometry like paper, polyethylene, marble, granite etc. The radon diffusion coefficient and diffusion length depend upon the porosity and density of materials for powder samples.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 50 条
  • [31] EFFECTIVE DIFFUSION-COEFFICIENT OF RADON IN CONCRETE THEORY AND METHOD FOR FIELD MEASUREMENTS
    CULOT, MVJ
    OLSON, HG
    SCHIAGER, KJ
    HEALTH PHYSICS, 1976, 30 (03): : 263 - 270
  • [32] Characterisation of the gas transport properties of porous materials by determining the radon diffusion coefficient
    Klink, T
    Gaber, K
    Schlattner, E
    Setzer, MJ
    MATERIALS AND STRUCTURES, 1999, 32 (224) : 749 - 754
  • [33] Comparison of results from indoor radon measurements using active and passive methods with those from mathematical modeling
    Visnuprasad, A. K.
    Roy, K. E. Reby
    Jojo, P. J.
    Sahoo, B. K.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2019, 58 (03) : 345 - 352
  • [34] New method and installation for rapid determination of radon diffusion coefficient in various materials
    Tsapalov, Andrey
    Gulabyants, Loren
    Livshits, Mihail
    Kovler, Konstantin
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2014, 130 : 7 - 14
  • [35] Comparison of results from indoor radon measurements using active and passive methods with those from mathematical modeling
    A. K. Visnuprasad
    K. E. Reby Roy
    P. J. Jojo
    B. K. Sahoo
    Radiation and Environmental Biophysics, 2019, 58 : 345 - 352
  • [36] Sensitivity analysis of an improved method for measuring the radon diffusion coefficient of porous materials
    van der Spoel, WH
    van der Pal, M
    Natural Radiation Environment VII, 2005, 7 : 740 - 748
  • [37] Multilayer Stack Method for Precise Measurement of Radon Diffusion Coefficient of Different Materials
    Kumar, Amit
    Parkash, Rajat
    Garg, Ajay
    Mann, Nisha
    Lal, Jawahar
    Chauhan, R. P.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2023, 61 (06) : 450 - 454
  • [38] Development of a robust and precise methodology for the measurement of the radon diffusion coefficient in diverse materials
    Castano-Casco, E.
    Gutierrez-Alvarez, I.
    Barba-Lobo, A.
    Bolivar, J. P.
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 440
  • [39] Characterisation of the gas transport properties of porous materials by determining the radon diffusion coefficient
    T. Klink
    K. Gaber
    E. Schlattner
    M. J. Setzer
    Materials and Structures, 1999, 32 : 749 - 754
  • [40] COMPARISON OF RADON MASS EXHALATION RATE MEASUREMENTS FROM BUILDING MATERIALS BY TWO DIFFERENT METHODS
    Soares, Sandra
    Kessongo, Joaquim
    Bahu, Yoenls
    Peralta, Luis
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (02) : 255 - 259