Accuracy of Implant Placement Utilizing 3D Printed and Thermoplastic Surgical Guides: A CBCT-Analysis

被引:1
|
作者
Al-Hamdan, Khalid [1 ]
Al Oaibi, Abdulrahman [2 ]
AlWadai, Turki [2 ]
Al-Fadda, Abdullah [2 ]
机构
[1] King Saud Univ, Dept Periodont & Community Dent, Coll Dent, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Dent, Internship Program, Riyadh, Saudi Arabia
来源
关键词
CBCT; DENTAL IMPLANT; 3D-PRINTED GUIDE;
D O I
10.21786/bbrc/13.3/34
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To achieve desirable functional and esthetic objectives in implant treatment, detailed case study, and planning is required. Since the introduction of 3D-printed technology into multiple fields, such as medicine and engineering, the use of this technology in dentistry is still to be explored. This study aimed to assess implant placement accuracy using two different implant surgical guides: thermoplastic (TP) and 3D-printed. Thirty acrylic resin mandibles missing the second premolar were fabricated with stereolithography (SLA) based on data from the CBCT scan. 15 TP and 15 3D-printed guides were constructed for the placement of the implants in relation to the mental foramen, and virtual implant apex distance from the mental foramen was set as 3.18 mm. 30 dummy 3.5 x 8mm implants were installed into the replica jaw models. Post-placement CBCT scans were compared to the virtual implant placement in relation to the mental foramen with the actual implant placement. The mean +/- SD of the implant distance to mental foramen for the 3D and TP guides was 3.12 +/- 0.36 mm and 2.52 +/- 0.83 mm (P<0.05); respectively. The deviation apex of the implant for the 3D-printed and TP guides was 0.92 +/- 0.14 mm and 1.57 +/- 0.45 mm (P<0.001); respectively. The angular deviation of the 3D-printed and TP guides was 3.33 +/- 0.860 and 4.03 +/- 1.130, respectively. Based on this study, the 3D printed guides were more accurate than the TP guides in terms of implant placement accuracy in relation to an important landmark and 3D implant placement.
引用
收藏
页码:1210 / 1213
页数:4
相关论文
共 50 条
  • [31] Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement
    Ozan, Oguz
    Turkyilmaz, Ilser
    Ersoy, Ahmet Ersan
    McGlumpby, Edwin A.
    Rosenstiel, Stephen F.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (02) : 394 - 401
  • [32] Accurate ACL tunnel placement using 3D surgical guides planned and printed at the point of care - A cadaveric feasibility study
    Eberlein, Sophie C.
    Hess, Silvan
    Klenke, Frank Michael
    Hecker, Andreas
    SWISS MEDICAL WEEKLY, 2023, 153 : 83S - 83S
  • [33] Implant is 3D printed for porosity
    1600, Elsevier Ltd (71):
  • [34] 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study
    Sigmar Schnutenhaus
    Cornelia Edelmann
    Heike Rudolph
    Jens Dreyhaupt
    Ralph G. Luthardt
    Clinical Oral Investigations, 2018, 22 : 2363 - 2372
  • [35] 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Rudolph, Heike
    Dreyhaupt, Jens
    Luthardt, Ralph G.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (06) : 2363 - 2372
  • [36] Accuracy of commercial 3D printers for the fabrication of surgical guides in dental implantology
    l'Alzit, Francois Rouze
    Cade, Romain
    Naveau, Adrien
    Babilotte, Joanna
    Meglioli, Matteo
    Catros, Sylvain
    JOURNAL OF DENTISTRY, 2022, 117
  • [37] Accuracy of guide wire placement for femoral neck stabilization using 3D printed drill guides (vol 8, 19, 2022)
    Roytman, Gregory R.
    Ramji, Alim F.
    Beitler, Brian
    Yoo, Brad
    Leslie, Michael P.
    Baumgaertner, Michael
    Tommasini, Steven
    Wiznia, Daniel H.
    3D PRINTING IN MEDICINE, 2022, 8 (01)
  • [38] The application of 3D printed surgical guides in resection and reconstruction of malignant bone tumor
    Wang, Fengping
    Zhu, Jun
    Peng, Xuejun
    Su, Jing
    ONCOLOGY LETTERS, 2017, 14 (04) : 4581 - 4584
  • [39] SciTable: A 3D Printed Surgical Table for Spinal Cord Implant Procedures
    Yano, Kim Mansur
    Nunes Netto, Severino Peixoto
    Costa Silva, Mayara Jully
    Barreto Suassuna, Alice de Oliveira
    de Mesquita, Fernanda Cristina
    Arboes, Valeria
    Araujo, Mariana
    Brasil, Fabricio Lima
    Lima Nascimento, Manuela Sales
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2, 2019, 70 (02): : 623 - 628
  • [40] ACCURACY OF IMPLANT PLACEMENT USING PRECISION SURGICAL GUIDES WITH VARYING OCCLUSOGINGIVAL HEIGHTS: AN IN VITRO STUDY
    Park, Chanseop
    Raigrodski, Ariel J.
    Rosen, Jacob
    Spiekerman, Charles
    London, Robert M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (06): : 372 - 381