Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements

被引:32
|
作者
Ferferieva, V. [1 ]
Van den Bergh, A. [2 ]
Claus, P. [1 ]
Jasaityte, R. [1 ]
La Gerche, A. [1 ]
Rademakers, F. [1 ]
Herijgers, P. [2 ]
D'hooge, J. [1 ]
机构
[1] Katholieke Univ Leuven, Louvain, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Louvain, Belgium
关键词
Strain; Strain rate; Tissue Doppler; Speckle tracking; Contractility; REGIONAL MYOCARDIAL-FUNCTION; MURINE MODEL; IMAGING PREDICTS; HEART-FAILURE; INFARCTION; ABNORMALITIES;
D O I
10.1093/ehjci/jes274
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n 8), myocardial infarction (n 8) and transaortic constriction (n 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 g/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r 0.64 and 0.71 for TDI; r 0.46 and 0.50 for STI, P 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r 0.60 and r 0.63, P 0.05). During stress, however, TDI-estimatedScirc and SRcirc values were predominantly higher than those measured by STI (P 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the BlandAltman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.
引用
收藏
页码:765 / 773
页数:9
相关论文
共 50 条
  • [21] Longitudinal strain and strain rate by two-dimensional speckle tracking in non-sedated healthy cats
    Silva, A. C.
    Muzzi, R. A. L.
    Oberlender, G.
    Nogueira, R. B.
    Muzzi, L. A. L.
    Reis, G. F. M.
    Mantovani, M. M.
    RESEARCH IN VETERINARY SCIENCE, 2013, 95 (03) : 1175 - 1180
  • [22] FUSION OF TISSUE DOPPLER AND SPECKLE TRACKING IN ECHOCARDIOGRAPHY IMAGES: COMPARISON WITH SPECKLE TRACKING ECHOCARDIOGRAPHY
    Bhatia, Nirmanmoh
    Tavakoli, Vahid
    Stoddard, Marcus
    Amini, Amir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1094 - E1094
  • [23] Left atrial strain and strain rate before and following restrictive annuloplasty for ischaemic mitral regurgitation evaluated by two-dimensional speckle tracking echocardiography
    Luca', F.
    Van Garsse, L.
    Rao, C. M.
    Cheriex, E.
    Puntrello, G.
    Rubino, G.
    Benedetto, D.
    Parise, O.
    Maessen, J. G.
    Gelsomino, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 857 - 857
  • [24] Left atrial strain and strain rate before and following restrictive annuloplasty for ischaemic mitral regurgitation evaluated by two-dimensional speckle tracking echocardiography
    van Garsse, Leen
    Gelsomino, Sandro
    Luca, Fabiana
    Parise, Orlando
    Cheriex, Emile
    Rao, Carmelo Massimiliano
    Gensini, Gian Franco
    Maessen, Jos G.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (06) : 534 - 543
  • [25] Normal Ranges of Right Atrial Strain and Strain Rate by Two-Dimensional Speckle-Tracking Echocardiography: A Systematic Review and Meta-Analysis
    Hosseinsabet, Ali
    Mahmoudian, Roshanak
    Jalali, Arash
    Mohseni-Badalabadi, Reza
    Davarpasand, Tahereh
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [26] CORRELATION BETWEEN THREE-DIMENSIONAL ECHOCARDIOGRAPHY EJECTION FRACTION WITH TWO-DIMENSIONAL SPECKLE TRACKING ECHOCARDIOGRAPHY STRAIN VARIABLES
    Salgado, Benjamin C.
    Vaidya, Gaurang
    Badar, Faraz
    Stoddard, Marcus
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1668 - 1668
  • [27] Subclinical cardiac dysfunction in pediatric kidney transplant recipients: Cardiac strain measurements by two-dimensional speckle tracking echocardiography
    Barczi, Adrienn
    Lakatos, Balint
    Vegh, Anna
    Kis, Eva
    Cseprekal, Orsolya
    Fabian, Alexandra
    Kovacs, Attila
    Szabo, Attila J.
    Merkely, Bela
    Salvi, Paolo
    Reusz, Gyorgy S.
    PEDIATRIC TRANSPLANTATION, 2022, 26
  • [28] Two-dimensional speckle tracking echocardiography demonstrates no effect of active acromegaly on left ventricular strain
    Volschan, I. C. M.
    Kasuki, L.
    Silva, C. M. S.
    Alcantara, M. L.
    Saraiva, R. M.
    Xavier, S. S.
    Gadelha, M. R.
    PITUITARY, 2017, 20 (03) : 349 - 357
  • [29] Comparison of myocardial tissue velocities measured by two-dimensional speckle tracking and tissue Doppler imaging
    Ng, Arnold C. T.
    Tran, Da T.
    Newman, Mark
    Allman, Christine
    Vidaic, Jane
    Kadappu, Krishna Kishor
    Boyd, Anita
    Thomas, Liza
    Leung, Dominic Y.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (06): : 784 - 789
  • [30] Evaluation of the left ventricular systolic strain in hypocalcemic infants with two-dimensional speckle tracking echocardiography
    Aboelata, Shaimaa
    Elmarsafawy, Hala
    Atwa, Mohamed A.
    Wahba, Yahya
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (04): : 568 - 575