Tuned mass damper on a damped structure

被引:29
|
作者
Fang, Huangcheng [1 ,2 ]
Liu, Lin [1 ]
Zhang, Dingli [2 ]
Wen, Ming [2 ]
机构
[1] Beijing Jiaotong Univ, Sch Civil Engn, Beijing 100044, Peoples R China
[2] Beijing Jiaotong Univ, Key Lab Urban Underground Engn, Minist Educ, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
damped structure; frequency analysis; modal damping; optimal damping ratio; optimal frequency ratio; tuned mass damper; OPTIMAL-DESIGN; TMD; VIBRATIONS; ABSORBER;
D O I
10.1002/stc.2324
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The classic design of the tuned mass damper on an undamped structure is based on the fixed-point theory introduced by Den Hartog. Because of the lack of fixed points in the dynamic amplification of damped structures, a generalization of previous methods is presented in this study to identify the optimal parameters of the damper. The optimal frequency is identified by analyzing complex natural frequencies. The resulting frequency leads to a confluence point in the complex frequency locus and an equal modal damping ratio for the two vibration modes, provided that the damping ratio of the damper is less than a critical value. This critical value can be used as an upper bound of the damping ratio value in practice that can effectively restrict the relative motion of the damper. The optimal damping ratio is identified by ensuring that the dynamic amplification reaches an extremum value at a reference frequency. It is demonstrated that the resulting damping ratio accounts for the reduction in the motion of the primary structure and relative motion of the damper. Furthermore, a modified design procedure is proposed to determine the optimal parameters of the damper for damped structures with multiple degrees of freedom. Several numerical experiments indicate the efficiency of the proposed parameters and design procedure.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A rooftop tuned mass damper frame
    Johnson, JG
    Reaveley, LD
    Pantelides, C
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (06): : 965 - 984
  • [22] Effect of Soil and Structure Nonlinear Interaction on the Efficiency of Tuned Mass Damper
    Masaeli, Hamid
    Panahi, Mehdi
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (10): : 2474 - 2490
  • [23] Vibration Control of a Pipeline Structure Using Pounding Tuned Mass Damper
    Song, G. B.
    Zhang, P.
    Li, L. Y.
    Singla, M.
    Patil, D.
    Li, H. N.
    Mo, Y. L.
    JOURNAL OF ENGINEERING MECHANICS, 2016, 142 (06)
  • [24] Random vibration analysis of nonlinear structure with pounding tuned mass damper
    Qian, Jiamin
    Chen, Lincong
    PROBABILISTIC ENGINEERING MECHANICS, 2022, 70
  • [25] Seismic control of structure with phase control active tuned mass damper
    Lai, Yong-An
    Luo, Wei-Chen
    Huang, Shieh-Kung
    Yang, Cho-Yen
    Chang, Chia-Ming
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (07):
  • [26] Supertall buildings with tuned mass damper
    Youssef, Nabih
    Structural Design of Tall Buildings, 1994, 3 (01): : 1 - 12
  • [27] Series-Type Pendulum Tuned Mass Damper-Tuned Sloshing Damper
    Love, J. S.
    McNamara, K. P.
    Tait, M. J.
    Haskett, T. C.
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2020, 142 (01):
  • [28] Comparison study of damping performance between tuned mass damper and tuned particle damper
    Lu, Zheng
    Liao, Yuan
    Lu, Xilin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (12): : 163 - 168
  • [29] Seismic performances of a structure equipped with a large mass ratio multiple tuned mass damper
    Kang, Ying-jie
    Peng, Ling-yun
    Pan, Peng
    Wang, Hai-shen
    Xiao, Gen-qi
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (17):
  • [30] Experimental investigation of vibration attenuation using nonlinear tuned mass damper and pendulum tuned mass damper in parallel
    Sun, C.
    Nagarajaiah, S.
    Dick, A. J.
    NONLINEAR DYNAMICS, 2014, 78 (04) : 2699 - 2715