Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

被引:2
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Juelich, INM4, Julich, Germany
关键词
MR/PET; Template-based attenuation correction; Errors;
D O I
10.1016/j.nima.2012.09.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. Conclusions: The present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [31] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [32] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [33] The impact of MR-based attenuation correction in spinal cord FDG-PET/MR imaging for neurological studies
    Brancato, Valentina
    Borrelli, Pasquale
    Alfano, Vincenzo
    Picardi, Marco
    Mascalchi, Mario
    Nicolai, Emanuele
    Salvatore, Marco
    Aiello, Marco
    MEDICAL PHYSICS, 2021, 48 (10) : 5924 - 5934
  • [34] ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment
    Sgard, Brian
    Khalife, Maya
    Bouchut, Arthur
    Fernandez, Brice
    Soret, Marine
    Giron, Alain
    Zaslavsky, Clara
    Delso, Gaspar
    Habert, Marie-Odile
    Kas, Aurelie
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1770 - 1779
  • [35] ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment
    Brian Sgard
    Maya Khalifé
    Arthur Bouchut
    Brice Fernandez
    Marine Soret
    Alain Giron
    Clara Zaslavsky
    Gaspar Delso
    Marie-Odile Habert
    Aurélie Kas
    European Radiology, 2020, 30 : 1770 - 1779
  • [36] MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon A.
    Aarsvold, John N.
    Raghunath, Nivedita
    Cervo, Morgan
    Stark, Rebecca
    Meltzer, Carolyn C.
    Votaw, John R.
    MEDICAL PHYSICS, 2012, 39 (10) : 6443 - 6454
  • [37] Quantitative evaluation of improved MR-based attenuation correction for brain PET/MRI studies
    An, Hyun Joon
    Seo, Seongho
    Kang, Hyejin
    Choi, Hongyoon
    Cheon, Gi Jeong
    Lee, Dong Soo
    Song, In Chan
    Kim, Yu Kyeong
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [38] Accurate hybrid template-based and MR-based attenuation correction using UTE images for simultaneous PET/MR brain imaging applications
    Baran, Jakub
    Chen, Zhaolin
    Sforazzini, Francesco
    Ferris, Nicholas
    Jamadar, Sharna
    Schmitt, Ben
    Faul, David
    Shah, Nadim Jon
    Cholewa, Marian
    Egan, Gary F.
    BMC MEDICAL IMAGING, 2018, 18
  • [39] Accuracy of a new atlas-based attenuation correction method in comparison to standard MR-based attenuation correction of the skull region in PET/MR imaging
    Rausch, I.
    Rischka, L.
    Ladefoged, C. N.
    Fenchel, M.
    Hahn, A.
    Lanzenberger, R.
    Traub-Weidinger, T.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S78 - S78
  • [40] Image artifacts from MR-based attenuation correction in dedicated PET/MR breast coil for PET/MR mammography
    Ihnho Cho
    Eunjung Kong
    Kyunga Chun
    EJNMMI Physics, 2 (Suppl 1)