Improving the surface metrology accuracy of optical profilers by using multiple measurements

被引:4
|
作者
Xu, Xudong [1 ,2 ]
Huang, Qiushi [1 ,2 ]
Shen, Zhengxiang [1 ,2 ]
Wang, Zhanshan [1 ,2 ]
机构
[1] Tongji Univ, Minist Educ, Key Lab Adv Microstruct Mat, Shanghai 200092, Peoples R China
[2] Tongji Univ, Inst Precis Opt Engn, Sch Phys Sci & Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
optical profilers; noise reduction; surface metrology; multiple measurements; power spectral density; ERRORS; PERFORMANCE; SCATTERING; ROUGHNESS; QUALITY; MIRRORS;
D O I
10.1117/1.OE.55.10.104105
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The performance of high-resolution optical systems is affected by small angle scattering at the midspatial- frequency irregularities of the optical surface. Characterizing these irregularities is, therefore, important. However, surface measurements obtained with optical profilers are influenced by additive white noise, as indicated by the heavy-tail effect observable on their power spectral density (PSD). A multiple-measurement method is used to reduce the effects of white noise by averaging individual measurements. The intensity of white noise is determined using a model based on the theoretical PSD of fractal surface measurements with additive white noise. The intensity of white noise decreases as the number of times of multiple measurements increases. Using multiple measurements also increases the highest observed spatial frequency; this increase is derived and calculated. Additionally, the accuracy obtained using multiple measurements is carefully studied, with the analysis of both the residual reference error after calibration, and the random errors appearing in the range of measured spatial frequencies. The resulting insights on the effects of white noise in optical profiler measurements and the methods to mitigate them may prove invaluable to improve the quality of surface metrology with optical profilers. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Improving the accuracy of chlorophyll fluorescence measurements
    Harbinson, Jeremy
    PLANT CELL AND ENVIRONMENT, 2013, 36 (10): : 1751 - 1754
  • [42] IMPROVING THE ACCURACY OF GEOMAGNETIC INTENSITY MEASUREMENTS
    WALTON, D
    NATURE, 1987, 328 (6133) : 789 - 791
  • [43] Accuracy of standard craniometric measurements using multiple data formats
    Richard, Adam H.
    Parks, Connie L.
    Monson, Keith L.
    FORENSIC SCIENCE INTERNATIONAL, 2014, 242 : 177 - 185
  • [44] IMPROVING THE ACCURACY OF DC POTENTIOMETER MEASUREMENTS
    CHADNOI, AE
    ONOPRICH, OK
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (03): : 253 - 254
  • [45] IMPROVING ACCURACY OF PULSE MAGNETOMETER MEASUREMENTS
    LACHINOV, VM
    MAKOVEEV, VK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (05) : 1403 - 1406
  • [46] Methods of improving the accuracy of vibration measurements
    Mnaokhin, A.E.
    Petrovich, V.I.
    Measurement Techniques, 1988, 31 (05) : 465 - 468
  • [47] IMPROVING THE ACCURACY OF MEASUREMENTS AND FLAW DETECTION
    ONISHCHENKO, AM
    INDUSTRIAL LABORATORY, 1993, 59 (10): : 952 - 961
  • [48] METHODS OF IMPROVING THE ACCURACY OF VIBRATION MEASUREMENTS
    MANOKHIN, AE
    PETROVICH, VI
    MEASUREMENT TECHNIQUES USSR, 1988, 31 (05): : 465 - 468
  • [49] Precision Metrology Using Weak Measurements
    Zhang, Lijian
    Datta, Animesh
    Walmsley, Ian A.
    PHYSICAL REVIEW LETTERS, 2015, 114 (21)
  • [50] Specification of Optical Surface Accuracy Using the Structure Function
    Zhelem, Ross
    MODELING ASPECTS IN OPTICAL METROLOGY III, 2011, 8083