Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) for Quantitative Analysis in Environmental and Life Sciences: A Review of Challenges, Solutions, and Trends

被引:207
|
作者
Proefrock, Daniel [1 ]
Prange, Andreas [1 ]
机构
[1] Helmholtz Zentrum Geesthacht, Zentrum Mat & Kustenforsch, Dept Marine Bioanalyt Chem, D-21502 Geesthacht, Germany
关键词
Inductively couple plasma-mass spectrometry; ICP-MS; Hyphenated techniques; Isotope dilution; Quantification; Environment; Proteomics; Chromatography; Trace elements; Heteroelements; ISOTOPE-DILUTION ANALYSIS; CAPILLARY LIQUID-CHROMATOGRAPHY; DYNAMIC REACTION CELL; SOLID-PHASE MICROEXTRACTION; AGENT DEGRADATION-PRODUCTS; ATOMIC-EMISSION DETECTION; OCTOPOLE REACTION CELL; OF-THE-ART; PROTEIN-PHOSPHORYLATION ANALYSIS; BIOINORGANIC SPECIATION ANALYSIS;
D O I
10.1366/12-06681
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This focal point review provides an overview of recent developments and capabilities of inductively coupled plasma mass spectrometry (ICP-MS) coupled with different separation techniques for applications in the fields of quantitative environmental and bio-analysis. Over the past years numerous technical improvements, which are highlighted in this review, have helped to promote the evolution of ICP-MS to one of the most versatile tools for elemental quantification. In particular, the benefits and possibilities of using state-of-the-art hyphenated ICP-MS approaches for quantitative analysis are demonstrated with a focus on environmental and bio-analytical applications.
引用
收藏
页码:843 / 868
页数:26
相关论文
共 50 条
  • [31] The use of laser ablation inductively coupled plasma-mass spectrometry (LA ICP-MS) for the analysis of fly ash
    Spears, DA
    FUEL, 2004, 83 (13) : 1765 - 1770
  • [32] Six Key Errors to Avoid for Routine Analysis Using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)
    Kutscher, Daniel
    SPECTROSCOPY, 2019, 34 (08) : 28 - 30
  • [33] Elemental Analysis of Tree Nuts and Their Pressed Oils by Triple Quadrupole Inductively Coupled Plasma-Mass Spectrometry (ICP-MS/MS)
    Ni, Zhanglin
    Yang, Ling
    Qu, Minghua
    Li, Zhengxiang
    Tang, Fubin
    ANALYTICAL LETTERS, 2025, 58 (01) : 79 - 90
  • [34] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [35] New advances in inductively coupled plasma-mass spectrometry (ICP-MS) for routine measurements in the nuclear industry
    Henry R.
    Koller D.
    Liezers M.
    Farmer lll O.T.
    Barinaga C.
    Wacker J.
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 249 (01) : 103 - 108
  • [36] INDUCTIVELY-COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS)
    DOUGLAS, DJ
    HOUK, RS
    PROGRESS IN ANALYTICAL ATOMIC SPECTROSCOPY, 1985, 8 (01): : 1 - 18
  • [37] Inductively coupled plasma-mass spectrometry (ICP-MS) detection of trace metal contents of children cosmetics
    Kopru, Semiha
    Soylak, Mustafa
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (03)
  • [38] DETERMINATION OF RATIOS OF MINOR ISOTOPES OF CALCIUM BY USING INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    SERFASS, RE
    KNISELEY, RN
    SMITH, FG
    FASEB JOURNAL, 1992, 6 (05): : A1788 - A1788
  • [39] Multi-element determination in complex matrices by inductively coupled plasma-mass spectrometry (ICP-MS)
    Holmes, LJ
    Robinson, VJ
    Makinson, PR
    Livens, FR
    SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 173 (1-6) : 345 - 350
  • [40] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371