Electrochemical Determination of Morin in Natural Food Using a Chitosan-Graphene Glassy Carbon Modified Electrode

被引:3
|
作者
Nagles, Edgar [1 ]
Bello, Monica [2 ]
Hurtado, John J. [3 ]
机构
[1] Univ Nacl Mayor San Marcos, Fac Quim & Ingn Quim, Lima 15081, Peru
[2] Univ Nacl Federico Villareal, Fac Ciencias Nat & Matemat, Lima 15001, Peru
[3] Univ Los Andes, Dept Quim, Carrera 1 18A-12, Bogota 111711, Colombia
关键词
glassy carbon; chitosan; graphene; morin; square wave voltammetry; ASCORBIC-ACID; URIC-ACID; DOPAMINE; OXIDE; ELECTROOXIDATION; NANOPARTICLES; COMPOSITE; EFFICIENT; SENSORS; RUTIN;
D O I
10.3390/s22207780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report presents a new application for the chitosan-graphene glassy carbon electrode (Ch-G/GCE) system in the determination of the hydroxyflavonoid morin (MR), one of the flavonoids with the highest favorable activity for people, due to its natural properties by square-wave voltammetry (SWV). The anodic peak current for MR was observed at 0.50 V with an increase of 73% compared with the glassy carbon electrode unmodified. The surface areas of Ch-G/GCE, Ch/GCE and GCE evaluated by cyclic voltammetry were 0.140, 0.053 and 0.011 cm(2), respectively. Additionally, an increase greater than 100% compared to the electrode without modification was observed. The detection limit was 0.30 mu mol/L for MR, and the relative standard deviations (RSDs) were 1.8% (n = 6). Possible interferences as quercetin, rutin, and applications in real samples were also evaluated with very acceptable results.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Sensitive Electrochemical Determination of Oxcarbazepine using MWCNT Modified Glassy Carbon Electrode
    Ershad, Sohrab
    Sani, Mahnaz Akbari
    Hosseinzadeh, Mehdi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (08): : 637 - 649
  • [42] Electrochemical determination of ajmalicine using glassy carbon electrode modified with gold nanoparticles
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Ortner, Astrid
    Kalcher, Kurt
    MONATSHEFTE FUR CHEMIE, 2016, 147 (07): : 1161 - 1166
  • [43] Electrochemical determination of imidacloprid using poly(carbazole)/chemically reduced graphene oxide modified glassy carbon electrode
    Lei, Wu
    Wu, Qiuju
    Si, Weimeng
    Gu, Zhenyan
    Zhang, Yuehua
    Deng, Jiping
    Hao, Qingli
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 102 - 109
  • [44] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [45] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [46] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid with Chitosan-Graphene Modified Electrode
    Han, Dongxue
    Han, Tingting
    Shan, Changsheng
    Ivaska, Ari
    Niu, Li
    ELECTROANALYSIS, 2010, 22 (17-18) : 2001 - 2008
  • [47] A glassy carbon electrode modified with carbon nanoonions for electrochemical determination of fentanyl
    Sohouli, Esmail
    Keihan, Amir Homayoun
    Shahdost-fard, Faezeh
    Naghian, Ebrahim
    Plonska-Brzezinska, Marta E.
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [48] Determination of Rutin by a Graphene-Modified Glassy Carbon Electrode
    Lei, Yan
    Du, Danxin
    Tang, Lina
    Tan, Chenkun
    Chen, Keli
    Zhang, Guo-Jun
    ANALYTICAL LETTERS, 2015, 48 (06) : 894 - 906
  • [49] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [50] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984