Microfluidic Analyzer Enabling Quantitative Measurements of Specific Intracellular Proteins at the Single-Cell Level

被引:2
|
作者
Liu, Lixing [1 ,2 ]
Fan, Beiyuan [1 ,2 ]
Wang, Diancan [3 ]
Li, Xiufeng [1 ,2 ]
Song, Yeqing [3 ]
Zhang, Ting [1 ,2 ]
Chen, Deyong [1 ,2 ]
Wang, Yixiang [3 ]
Wang, Junbo [1 ,2 ]
Chen, Jian [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
[3] Peking Univ, Sch Stomatol, Beijing 10081, Peoples R China
来源
MICROMACHINES | 2018年 / 9卷 / 11期
基金
中国国家自然科学基金;
关键词
instrumentation; microfluidic flow cytometry; intracellular proteins; absolute quantification; FLOW-CYTOMETRY; HETEROGENEITY;
D O I
10.3390/mi9110588
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a microfluidic instrument capable of quantifying single-cell specific intracellular proteins, which are composed of three functioning modules and two software platforms. Under the control of a LabVIEW platform, a pressure module flushed cells stained with fluorescent antibodies through a microfluidic module with fluorescent intensities quantified by a fluorescent module and translated into the numbers of specific intracellular proteins at the single-cell level using a MATLAB platform. Detection ranges and resolutions of the analyzer were characterized as 896.78-6.78 x 10(5) and 334.60 nM for Alexa 488, 314.60-2.11 x 10(5) and 153.98 nM for FITC, and 77.03-5.24 x 10(4) and 37.17 nM for FITC-labelled anti-beta-actin antibodies. As a demonstration, the numbers of single-cell beta-actins of two paired oral tumor cell types and two oral patient samples were quantified as: 1.12 +/- 0.77 x 10(6)/cell (salivary adenoid cystic carcinoma parental cell line (SACC-83), n(cell) = 13,689) vs. 0.90 +/- 0.58 x 10(5)/cell (salivary adenoid cystic carcinoma lung metastasis cell line (SACC-LM), n(cell) = 15,341); 0.89 +/- 0.69 x 10(6)/cell (oral carcinoma cell line (CAL 27), n(cell) = 7357) vs. 0.93 +/- 0.69 x 10(6)/cell (oral carcinoma lymphatic metastasis cell line (CAL 27-LN2), n(cell) = 6276); and 0.86 +/- 0.52 x 10(6)/cell (patient I) vs. 0.85 +/- 0.58 x 10(6)/cell (patient II). These results (1) validated the developed analyzer with a throughput of 10 cells/s and a processing capability of similar to 10,000 cells for each cell type, and (2) revealed that as an internal control in cell analysis, the expressions of beta-actins remained stable in oral tumors with different malignant levels.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] A microfluidic platform enabling single-cell RNA-seq of multigenerational lineages
    Robert J. Kimmerling
    Gregory Lee Szeto
    Jennifer W. Li
    Alex S. Genshaft
    Samuel W. Kazer
    Kristofor R. Payer
    Jacob de Riba Borrajo
    Paul C. Blainey
    Darrell J. Irvine
    Alex K. Shalek
    Scott R. Manalis
    Nature Communications, 7
  • [12] Microfluidic Chip for Detection of Drug Resistance at the Single-cell Level
    Song, Kena
    Yu, Zhangqing
    Zu, Xiangyang
    Huang, Lei
    Fu, Dongliao
    Yao, Jingru
    Hu, Zhigang
    Xue, Yun
    MICROMACHINES, 2023, 14 (01)
  • [13] A droplet-based microfluidic flow cytometry enabling absolute quantification of single-cell proteins leveraging constriction channel
    Hongyu Yang
    Yuanchen Wei
    Beiyuan Fan
    Lixing Liu
    Ting Zhang
    Deyong Chen
    Junbo Wang
    Jian Chen
    Microfluidics and Nanofluidics, 2021, 25
  • [14] A droplet-based microfluidic flow cytometry enabling absolute quantification of single-cell proteins leveraging constriction channel
    Yang, Hongyu
    Wei, Yuanchen
    Fan, Beiyuan
    Liu, Lixing
    Zhang, Ting
    Chen, Deyong
    Wang, Junbo
    Chen, Jian
    MICROFLUIDICS AND NANOFLUIDICS, 2021, 25 (04)
  • [15] A multilayer microfluidic system for studies of the dynamic responses of cellular proteins to oxygen switches at the single-cell level
    Fu, Wei
    Wang, Shujing
    Ouyang, Qi
    Luo, Chunxiong
    INTEGRATIVE BIOLOGY, 2024, 16
  • [16] ANYL 34-Microfluidic electroporation for high-throughput differentiation of intracellular materials at the single-cell level
    Bao, Ning
    Wang, Jun
    Lu, Chang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [17] Fluorescence quantification of intracellular materials at the single-cell level by an integrated dual-well array microfluidic device
    Wang, Chenyu
    Ren, Lufeng
    Liu, Wenwen
    Wei, Qingquan
    Tan, Manqing
    Yu, Yude
    ANALYST, 2019, 144 (08) : 2811 - 2819
  • [18] Quantitative Analysis of Multiple Proteins of Different Invasive Tumor Cell Lines at the Same Single-Cell Level
    Zhang, Xiangchun
    Liu, Ru
    Shu, Qingming
    Yuan, Qing
    Xing, Gengmei
    Gao, Xueyun
    SMALL, 2018, 14 (17)
  • [19] Microfluidic single-cell measurements of oxidative stress as a function of cell cycle position
    Allcroft, Tyler J.
    Duong, Jessica T.
    Skardal, Per Sebastian
    Kovarik, Michelle L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (26) : 6481 - 6490
  • [20] Microfluidic single-cell measurements of oxidative stress as a function of cell cycle position
    Tyler J. Allcroft
    Jessica T. Duong
    Per Sebastian Skardal
    Michelle L. Kovarik
    Analytical and Bioanalytical Chemistry, 2023, 415 : 6481 - 6490