Motion measurements in low-contrast X-ray imagery

被引:0
|
作者
Berger, M [1 ]
Gerig, G [1 ]
机构
[1] ETH Zurich, Commun Technol Lab, CH-8092 Zurich, Switzerland
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Measuring motion in medical imagery becomes more and more important, in particular for object tracking, image registration, and local displacement measurements. Such measurements are especially difficult in megavoltage X-ray images (portal images), which are used to control the position of patients in high precision radiotherapy. Low contrast, blur, and noise render accurate measurements difficult. In this work we review the framework of a generic matching algorithm only based on the image signal and not on binary image features. Thus, the often unreliable step of feature extraction in such imagery is circumvented. Another major advantage is the possibility of self-diagnosis, which is used for restricting the transformation in motion measurements if the image quality is not sufficient. The method of digitally reconstructed radiographs (DRR) allow for the computation of error free reference images, avoiding the additional step of therapy simulation. The multi-modal match between such DRRs and portal images lead to an estimate of the patient position during radiotherapy treatment. Results of generated data with known ground truth as well as results of a multi-modal match are presented.
引用
收藏
页码:832 / 841
页数:10
相关论文
共 50 条
  • [31] LOW-ENERGY COSMIC X-RAY MEASUREMENTS
    BAXTER, AJ
    WILSON, BG
    GREEN, DW
    CANADIAN JOURNAL OF PHYSICS, 1969, 47 (23) : 2651 - &
  • [32] BEST IN PHYSICS (IMAGING): A Deep Learning Based Model Observer for Low-Contrast Object Detection Task in X-Ray Computed Tomography
    Gong, H.
    Yu, L.
    Leng, S.
    McCullough, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E565 - E565
  • [33] X-ray spectroscopy observation of fast ions generation in plasma produced by short low-contrast laser pulse irradiation of solid targets
    Faenov, A. Ya.
    Magunov, A. I.
    Pikuz, T. A.
    Skobelev, I. Yu
    Gasilov, S. V.
    Stagira, S.
    Calegari, F.
    Nisoli, M.
    De Silvestri, S.
    Poletto, L.
    Villoresi, P.
    Andreev, A. A.
    LASER AND PARTICLE BEAMS, 2007, 25 (02) : 267 - 275
  • [34] VESSEL SEGMENTATION IN LOW CONTRAST X-RAY ANGIOGRAM IMAGES
    Felfelian, B.
    Fazlali, H. R.
    Karimi, N.
    Soroushmehr, S. M. R.
    Samavi, S.
    Nallamothu, B.
    Najarian, K.
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2016, : 375 - 379
  • [35] Measurements of imaging parameters of a phase contrast x-ray imaging prototype
    Li, Yuhua
    Rong, John
    Chu, Robert Y. L.
    Zhang, Da
    Archer, Ann
    Fajardo, Laurie
    Chen, Wei R.
    Wu, Xizeng
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES III, 2008, 6857
  • [36] A Framework for Automatic Building Detection from Low-Contrast VHR Satellite Imagery
    Li, Junjun
    Cao, Jiannong
    ICVIP 2019: PROCEEDINGS OF 2019 3RD INTERNATIONAL CONFERENCE ON VIDEO AND IMAGE PROCESSING, 2019, : 52 - 56
  • [37] Perceptual learning and aging: improved performance for low-contrast motion discrimination
    Bower, Jeffrey D.
    Watanabe, Takeo
    Andersen, George J.
    FRONTIERS IN PSYCHOLOGY, 2013, 4
  • [38] A STATISTICAL EVALUATION OF CARDIAC MEASUREMENTS IMPLEMENTED BY X-RAY MOTION PICTURES
    PATEK, PR
    WEISMAN, S
    ANATOMICAL RECORD, 1954, 118 (02): : 337 - 338
  • [39] X-RAY MEASUREMENTS OF THERMAL MOTION IN HIGHLY ORIENTED PYROLYTIC GRAPHITE
    SPARKS, JC
    EPPERSON, JE
    CARBON, 1969, 7 (06) : 732 - &
  • [40] A new index for low-contrast detectability based on the radiation dose and measurements
    Okumura, M
    Kazama, M
    Nobuta, Y
    Rifu, T
    Tsukagoshi, S
    Muramatsu, Y
    RADIOLOGY, 2001, 221 : 366 - 367