Enhancement of Protective Ventilation Strategies Using Electrical Impedance Tomography

被引:0
|
作者
Luepschen, H. [1 ]
Meier, T. [2 ]
Leibecke, T. [3 ]
Grossherr, M. [2 ]
Leonhardt, S. [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst, Med Informat Technol, Pauwelsstr 20, D-52074 Aachen, Germany
[2] Univ Ctr Med Schleswig Holstein, Dept Anesthesiol, Lubeck, Germany
[3] Univ Ctr Med Schleswig Holstein, Dept Radiol, Lubeck, Germany
关键词
Protective ventilation; EIT; recruitment; PEEP trial; CT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The individualization of protective ventilation strategies for patients suffering from acute respiratory failure requires permanent bedside monitoring of pulmonary parameters and an immediate response to changing lung conditions. This can be achieved using the electrical impedance tomography (EIT), a fast, non-invasive technique to observe global and regional lung properties corresponding to changes in the conductivity distribution of the thorax. In this work, EIT has been evaluated in terms of its potential to assess different conditions of the lung during lung recruitment maneuvers (RM) which are frequently used for the treatment of respiratory failure. Therefore, an EIT system was integrated into a fuzzy-controller based medical expert system which is capable of automatically performing RM while recording physiological parameters. The setup additionally triggers a CT scanner to obtain reference images. Six anesthetized, artificially ventilated pigs received repetitive lung lavages with NaCl-solution to induce respiratory failure. In a first trial, PEEP was step-wise increased and subsequently decreased to examine the influence of PEEP on the patient. In a second trial, the expert system performed an automatic RM. Differential and functional EIT images were continuously recorded and compared to CT images made at the end of inspiration and expiration. Global impedance and mean lung density as well as tidal volume and tidal variation demonstrated a high linear correlation. However, the proportionality factor between the respective quantities changed with the state of lung recruitment. This was probably due to the grossly changing geometry of the conductivity distribution. During the automated RM, a clear shift of ventilation from dorsal to ventral regions of the lung could be observed in both, EIT and CT images. The experiments showed that EIT is capable of identifying dynamic changes in the lung such as global and regional recruitment and may provide important control variables for closed-loop protective ventilation controllers.
引用
收藏
页码:3902 / +
页数:2
相关论文
共 50 条
  • [11] Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    Grant, Caroline A.
    Trang Pham
    Hough, Judith
    Riedel, Thomas
    Stocker, Christian
    Schibler, Andreas
    CRITICAL CARE, 2011, 15 (01):
  • [12] Regional ventilation by electrical impedance tomography - A comparison with ventilation scintigraphy in pigs
    Hinz, J
    Neumann, P
    Dudykevych, T
    Andersson, LG
    Wrigge, H
    Burchardi, H
    Hedenstierna, G
    CHEST, 2003, 124 (01) : 314 - 322
  • [13] Electrical Impedance Tomography and Ventilation Heterogeneity on a Silicosis Patient
    Beder, T. N.
    Takizawa, D. B.
    Quizhpe, P. J.
    Macedo, B. R.
    Garcia, M.
    Tucci, M. R.
    Costa, E. L. V.
    Amato, M. B. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [14] Electrical impedance tomography for lung ventilation monitoring of the dog
    Gloning, Simon
    Pieper, Korbinian
    Zoeliner, Martin
    Meyer-Lindenberg, Andrea
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2017, 45 (01): : 15 - 21
  • [15] AN INTEGRATED PHYSIOLOGICAL MODEL OF THE LUNG MECHANICS AND GAS EXCHANGE USING ELECTRICAL IMPEDANCE TOMOGRAPHY IN THE ANALYSIS OF VENTILATION STRATEGIES IN ARDS PATIENTS
    Denai, M.
    Mahfouf, M.
    Wang, A.
    Linkens, D. A.
    Mills, G. H.
    BIOSIGNALS 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2010, : 208 - 213
  • [16] The time taken for the regional distribution of ventilation to stabilise: an investigation using electrical impedance tomography
    Caruana, L. R.
    Paratz, J. D.
    Chang, A.
    Barnett, A. G.
    Fraser, J. F.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (01) : 88 - 91
  • [17] PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography
    Zhao, Zhanqi
    Steinmann, Daniel
    Frerichs, Inez
    Guttmann, Josef
    Moeller, Knut
    CRITICAL CARE, 2010, 14 (01):
  • [18] PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography
    Zhanqi Zhao
    Daniel Steinmann
    Inéz Frerichs
    Josef Guttmann
    Knut Möller
    Critical Care, 14
  • [19] Longitudinal Characterization of Ventilation and Perfusion in Infants With Bronchopulmonary Dysplasia Using Electrical Impedance Tomography
    Enzer, K.
    Da Rosa, N. Barbosa Junior
    Keck, A.
    Hagopian, E.
    Brinton, J.
    Shishvan, O. Rajabi
    Saulnier, G.
    Newell, J.
    Isaacson, D.
    Mueller, J.
    Baker, C. D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [20] Assessment of lung ventilation in infants with respiratory distress syndrome using electrical impedance tomography
    Chatziioannidis, I
    Samaras, T.
    Mitsiakos, G.
    Karagianni, P.
    Nikolaidis, N.
    HIPPOKRATIA, 2013, 17 (02) : 115 - 119