Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system

被引:7
|
作者
Hod, E. A. [1 ,2 ]
Brugnara, C. [3 ,4 ]
Pilichowska, M. [5 ]
Sandhaus, L. M. [6 ]
Luu, H. S. [7 ]
Forest, S. K. [1 ,2 ]
Netterwald, J. C. [1 ]
Reynafarje, G. M. [2 ]
Kratz, A. [1 ,2 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Pathol & Cell Biol, 630 W 168th St, New York, NY 10032 USA
[2] NewYork Presbyterian Hosp, New York, NY USA
[3] Boston Childrens Hosp, Dept Lab Med, Boston, MA USA
[4] Harvard Med Sch, Boston, MA USA
[5] Tufts Med Ctr, Boston, MA USA
[6] Univ Hosp, Cleveland Med Ctr, Cleveland, OH USA
[7] Childrens Med Ctr Dallas, Dallas, TX USA
关键词
automated cell counters; cerebrospinal fluid testing; laboratory testing; red cell counts; white cell counts; BODY-FLUID MODE; REFLEX TESTING RULES; CEREBROSPINAL-FLUID; HEMATOLOGY ANALYZERS; SYSMEX XN-1000; ASCITIC FLUIDS; BLOOD-CELLS; XE-5000;
D O I
10.1111/ijlh.12728
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. Methods: The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. Results: The GloCyte detected as few as 1 TNC/mu L and 1 RBC/mu L, and reliably counted as low as 3 TNCs/mu L and 2RBCs/L. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. Conclusions: The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts.
引用
收藏
页码:56 / 65
页数:10
相关论文
共 50 条
  • [41] Multicenter analytical performance evaluation of the ST Genesia thrombin generation system
    Talon, Laurie
    Feriel, Joffrey
    Sinegre, Thomas
    Lebreton, Aurelien
    Lecomte, Melanie
    Hemar, Claire
    ANNALES DE BIOLOGIE CLINIQUE, 2025, 83 (-1) : 35 - 48
  • [42] Evaluation of PROCLEIX® WNV assay performance with cadaveric samples on the semi-automated ESAS and fully automated TIGRIS systems
    Cline, J.
    Cory, R.
    Garcia, A.
    Deras, M.
    Sosh, J.
    Broulik, A.
    Giachetti, C.
    Linnen, J. M.
    TRANSFUSION, 2006, 46 (09) : 163A - 163A
  • [43] A Prospective Multicenter Clinical Performance Evaluation of the C-CGM System
    Rebec, Mihailo
    Cai, Kevin
    Dutt-Ballerstadt, Ralph
    Anderson, Ellen
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 390 - 396
  • [44] Multicenter performance evaluation of the Alinity m CMV assay for quantifying cytomegalovirus DNA in plasma samples
    Lee, Miae
    Albert, Eliseo
    Wessels, Els
    Kim, Soo-Kyung
    Chung, Hae-Sun
    Gimenez, Estela
    Vreeswijk, Tom
    Claas, Eric C. J.
    Tai, Yan Chin
    Reinhardt, Birgit
    Sasaki, Mark M.
    Navarro, David
    JOURNAL OF CLINICAL MICROBIOLOGY, 2023, 61 (10)
  • [45] Evaluation of PREVI Color Gram Automated Staining System on Positive Blood Culture Samples
    Wong, River C. W.
    Heung, Samuel S. Y.
    Ho, Y. C.
    Yip, K. T.
    Que, T. L.
    LABMEDICINE, 2011, 42 (07): : 414 - 418
  • [46] Performance Evaluation of Automated Impedance and Optical Fluorescence Platelet Counts Compared With International Reference Method in Patients With Thalassemia
    Tantanate, Chaicharoen
    Khowawisetsut, Ladawan
    Pattanapanyasat, Kovit
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2017, 141 (06) : 830 - 836
  • [47] Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples
    Choi, Qute
    Kim, Hyun Jin
    Kim, Jong Wan
    Kwon, Gye Cheol
    Koo, Sun Hoe
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (05)
  • [48] Multicenter evaluation of the BD phoenix automated microbiology system for antimicrobial susceptibility testing of Streptococcus species
    Richter, Sandra S.
    Howard, Wanita J.
    Weinstein, Melvin P.
    Bruckner, David A.
    Hindler, Janet F.
    Saubolle, Michael
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (09) : 2863 - 2871
  • [49] Final performance evaluation of the automated lightning detection and reporting system (ALDARS)
    Kraus, KA
    Seliga, TA
    Kranz, JR
    16TH INTERNATIONAL CONFERENCE ON INTERACTIVE INFORMATION AND PROCESSING SYSTEMS (IIPS) FOR METEOROLOGY, OCEANOGRAPHY AND HYDROLOGY, 2000, : 106 - 109
  • [50] PERFORMANCE EVALUATION OF MILES IMMUNO-1 AUTOMATED IMMUNOASSAY SYSTEM
    CHEN, IW
    AYRES, M
    JENKINS, S
    CLINICAL CHEMISTRY, 1995, 41 (06) : S62 - S63