Application of Fe3O4 mesoporous sphere modified carbon ionic liquid electrode as electrochemical hemoglobin biosensor

被引:27
|
作者
Sun, Wei [1 ,2 ]
Sun, Zhaolan [2 ]
Zhang, Liqi [3 ]
Qi, Xiaowei [2 ]
Li, Guangjiu [2 ]
Wu, Jie [2 ]
Wang, Mei [3 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chem Engn, Haikou 571158, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
[3] Huazhong Univ Sci & Technol, State Key Lab Coal Combust, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Chitosan; Hemoglobin; Ionic liquid; Fe3O4 mesoporous spheres; Electrochemical biosensor; PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; SURFACTANT FILMS; ELECTROCATALYSIS; PROTEINS; NANOPARTICLES; CHITOSAN; MYOGLOBIN; NANOTUBE; BINDER;
D O I
10.1016/j.colsurfb.2012.06.010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new electrochemical hemoglobin (Hb) biosensor was constructed based on a Fe3O4 mesoporous spheres modified carbon ionic liquid electrode (CILE), which showed excellent electrocatalytic ability towards the reduction of trichloroacetic acid. CILE was prepared by using N-hexylpyridinium hexafluorophosphate (HPPF6) as the modifier and the binder in the carbon paste. Ultraviolet-visible and Fourier transform infrared spectroscopic results indicated that Hb molecules retained the native structure in the chitosan and Fe3O4 mesoporous spheres composite film. Electrochemical results indicated that a pair of well-defined redox peaks appeared in 0.1 mol/L phosphate buffer solution (PBS) with the formed potential (E-0') as -0.287 V (vs. SCE), indicating that the direct electron transfer of Hb in the composite film was realized. Electrochemical behaviors of Hb were carefully investigated with the electrochemical parameters such as electron transfer coefficient (alpha), electron transfer number (n), and heterogeneous electron transfer rate constant (k(s)) calculated. Due to the specific characteristics of Fe3O4 mesoporous spheres present on the electrode surface, the electron transfer rate of Hb was greatly promoted. The Hb modified electrode exhibited excellent electrocatalytic properties with wider linear range and lower detection limit. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [31] Electrochemical Detection of trace amount of Arsenic (III) at Glassy Carbon Electrode modified with Au/Fe3O4 Nanocomposites
    Toor, Sehaspreet Kaur
    Devi, Pooja
    Bansod, BabanKumar S.
    INTERNATIONAL CONFERENCE ON WATER RESOURCES, COASTAL AND OCEAN ENGINEERING (ICWRCOE'15), 2015, 4 : 1107 - 1113
  • [32] In situ electrochemical contact angle study of hemoglobin and hemoglobin–Fe3O4 nanocomposites
    Renyun Zhang
    Min Song
    Xiaomao Li
    Zhiqun Guan
    Xuemei Wang
    Analytical and Bioanalytical Chemistry, 2006, 386 : 2075 - 2079
  • [33] Fe3O4 modified mesoporous carbon nanospheres: Magnetically separable adsorbent for hexavalent chromium
    Li, Shuhui
    Liu, Lei
    Yu, Yifeng
    Wang, Guoxu
    Zhang, Hongliang
    Chen, Aibing
    JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 698 : 20 - 26
  • [34] Electrochemical determination of bisphenol A at ordered mesoporous carbon modified nano-carbon ionic liquid paste electrode
    Li, Yonghong
    Zhai, Xiurong
    Liu, Xinsheng
    Wang, Ling
    Liu, Herong
    Wang, Haibo
    TALANTA, 2016, 148 : 362 - 369
  • [35] Ordered mesoporous carbon modified carbon ionic liquid electrode for the electrochemical detection of double-stranded DNA
    Zhu, Zhihong
    Li, Xia
    Zeng, Yan
    Sun, Wei
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (10): : 2313 - 2317
  • [36] An electrochemical biosensor based on Nafion-ionic liquid and a myoglobin-modified carbon paste electrode
    Li, Xiaoqing
    Zhao, Ruijun
    Wang, Yan
    Sun, Xiaoying
    Sun, Wei
    Zhao, Changzhi
    Jiao, Kui
    ELECTROCHIMICA ACTA, 2010, 55 (06) : 2173 - 2178
  • [37] Electrochemical Biosensor Based on Hemoglobin and Titanate Nanotubes Modified Electrode and its Application
    Weng, Wenju
    Liu, Juan
    Yin, Chunxiao
    Xie, Hui
    Luo, Guiling
    Sung, Wei
    Li, Guangjiu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4309 - 4317
  • [38] An electrochemical sensor based on a glassy carbon electrode modified with optimized Cu–Fe3O4 nanocomposite for 4-nitrophenol detection
    Ke Cao
    Chenxi Si
    Haiyan Zhang
    Jiahao Hu
    Dan Zheng
    Journal of Materials Science: Materials in Electronics, 2022, 33 : 2386 - 2398
  • [39] Fe3O4@MoS2/rGO Nanocomposite/Ionic Liquid Modified Carbon Paste Electrode for Electrochemical Sensing of Dasatinib in the Presence of Doxorubicin
    Tajik, Somayeh
    Afshar, Abbas Aghaei
    Shamsaddini, Saeedeh
    Askari, Mohammad Bagher
    Dourandish, Zahra
    Nejad, Fariba Garkani
    Beitollahi, Hadi
    Di Bartolomeo, Antonio
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (11) : 4473 - 4480
  • [40] Electrochemical detection of sulfasalazine in real samples by GO/Fe3O4@SiO2 nanostructure and ionic liquid modified carbon paste electrode
    Jahani, Peyman Mohammadzadeh
    Jafari, Maedeh
    Gupta, Vinod Kumar
    Agarwal, Shilpi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07): : 6829 - 6840