Partial Discharge Characteristics of Electrical Treeing in XLPE Insulation Exposed to Voltages of Different Rise Times

被引:0
|
作者
Hammarstrom, T. J. A. [1 ]
Bengtsson, T. [1 ,2 ]
Gubanski, S. M. [1 ]
机构
[1] Chalmers Univ Technol, Dept Mat & Mfg Technol, SE-41296 Gothenburg, Sweden
[2] ABB Corp Res, SE-72178 Vasteras, Sweden
关键词
Partial discharges; PWM; square like voltages; measurements; Twisted pair; Motor winding;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of pulse width modulated (PWM) waveforms allows a more flexible energy applications and management The downside is that under such operating conditions the voltage stress imposed on the insulation systems increases, particularly as the frequency content is considerably higher than at the conventional 50 Hz sinusoidal waveform. Among various degradation mechanisms, electrical treeing is one important processes and it can be linked with a presence of partial discharge (PD) activity. In this paper, the changes in PD characteristics at different stages of degradation by electrical treeing were investigated for XLPE based insulation exposed to rapidly changing voltages of varying magnitude. The tested material samples were subjected to two square voltage shapes, each characterized by their rise-time. Here the shorter was 1 mu s and the longer 0.5 ms, all tests run at 414 Hz. To compare the voltage endurance, the voltage level was gradually increased until detectable PD activity and tree initiation could be observed, both electrically and optically. Typically continuous PD appearance was observed between 23 and 32 kVpp. The total number of PDs and their characteristics were monitored as the trees were gradually growing. Here the experimental results shows that the PDs appears at lower voltage magnitudes for the shorter rise times and that the trees had a significantly less branched appearance as compared to the longer voltage rise time. These results resemble the observations that recently been presented with tests on DC voltage pre-stressed material samples exposed to impulses of reversed polarity. Additionally the measured PD characteristics were non-symmetric, having a clear polarity dependence. This finding suggests a possibility to use the presented approach for a more detailed investigating of degradation processes in solid insulation systems suitable for both HVAC and HVDC applications.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 50 条
  • [31] DC polarization characteristics of XLPE and EPR insulation subjected to water treeing
    Abou-Dakka, M
    Bulinski, AT
    Bamji, SS
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 181 - 184
  • [32] Partial Discharge Characteristics and Development of Typical XLPE Power Cable Insulation Defects
    Zhao, Xuefeng
    Pu, Lu
    Ju, Zeli
    Ren, Shuangzan
    Duan, Wei
    Wang, Jianhui
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 623 - 626
  • [33] Characteristics of Partial Discharge in XLPE during Electrical Tree Initiation Process under Different Temperatures
    Peng, Suman
    Zhu, Xi
    Wu, Jiandong
    Yin, Yi
    PROCEEDINGS OF 2020 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2020), 2020, : 561 - 564
  • [34] The Measurement of Voltage Endurance Coefficient by Electrical Treeing Test for XLPE Cable Insulation
    Liu Ying
    Bat Hui
    Su Yu
    Cao Xiaolong
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 808 - 811
  • [35] UNDERSTANDING ELECTRICAL TREEING PHENOMENA IN GAMMA RAY IRRADIATED XLPE CABLE INSULATION
    Sarathti, R.
    Aryanandiny, B.
    Tanaka, Toshtkatsu
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [36] A study about partial discharge measurements performed applying to insulating systems square voltages with different rise times
    Guastavino, F
    Coletti, G
    Ratto, A
    Torello, E
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 418 - 421
  • [37] Aging diagnosis of insulation systems by PD measurements - Extraction of partial discharge features in electrical treeing
    Bozzo, R
    Gemme, C
    Guastavino, F
    Cacciari, M
    Contin, A
    Montanari, GC
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1998, 5 (01) : 118 - 124
  • [38] UNDERSTANDING ELECTRICAL TREEING PHENOMENA IN XLPE CABLE INSULATION ADOPTING UHF TECHNIQUE
    Sarathi, Ramanujam
    Nandini, Arya
    Danikas, Michael G.
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2011, 62 (02): : 73 - 79
  • [39] Understanding Electrical Treeing Activity in Electron Beam Irradiated XLPE Cable Insulation
    Gautam, Ribhu
    Vinu, R.
    Sarathi, R.
    Acharya, S.
    Kumar, Mukesh
    Sharma, Archana
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1652 - 1662
  • [40] Investigation on Electrical Treeing Characteristics of Thermally Aged XLPE Cable
    Samee, A.
    Li, Z. H.
    Zhang, C. H.
    Huang, Z. P.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 437 - +