Partial Discharge Characteristics of Electrical Treeing in XLPE Insulation Exposed to Voltages of Different Rise Times

被引:0
|
作者
Hammarstrom, T. J. A. [1 ]
Bengtsson, T. [1 ,2 ]
Gubanski, S. M. [1 ]
机构
[1] Chalmers Univ Technol, Dept Mat & Mfg Technol, SE-41296 Gothenburg, Sweden
[2] ABB Corp Res, SE-72178 Vasteras, Sweden
关键词
Partial discharges; PWM; square like voltages; measurements; Twisted pair; Motor winding;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of pulse width modulated (PWM) waveforms allows a more flexible energy applications and management The downside is that under such operating conditions the voltage stress imposed on the insulation systems increases, particularly as the frequency content is considerably higher than at the conventional 50 Hz sinusoidal waveform. Among various degradation mechanisms, electrical treeing is one important processes and it can be linked with a presence of partial discharge (PD) activity. In this paper, the changes in PD characteristics at different stages of degradation by electrical treeing were investigated for XLPE based insulation exposed to rapidly changing voltages of varying magnitude. The tested material samples were subjected to two square voltage shapes, each characterized by their rise-time. Here the shorter was 1 mu s and the longer 0.5 ms, all tests run at 414 Hz. To compare the voltage endurance, the voltage level was gradually increased until detectable PD activity and tree initiation could be observed, both electrically and optically. Typically continuous PD appearance was observed between 23 and 32 kVpp. The total number of PDs and their characteristics were monitored as the trees were gradually growing. Here the experimental results shows that the PDs appears at lower voltage magnitudes for the shorter rise times and that the trees had a significantly less branched appearance as compared to the longer voltage rise time. These results resemble the observations that recently been presented with tests on DC voltage pre-stressed material samples exposed to impulses of reversed polarity. Additionally the measured PD characteristics were non-symmetric, having a clear polarity dependence. This finding suggests a possibility to use the presented approach for a more detailed investigating of degradation processes in solid insulation systems suitable for both HVAC and HVDC applications.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 50 条
  • [1] Partial discharge characteristics of electrical treeing in XLPE insulation exposed to voltages of different rise times
    Hammarström T.
    Bengtsson T.
    Gubanski S.M.
    IEEJ Transactions on Fundamentals and Materials, 2019, 139 (02) : 85 - 91
  • [2] Effect of Aromatic Compounds Content on Electrical Treeing and Partial Discharge Characteristics of XLPE Insulation
    Lü L.
    Yang Z.
    Yao T.
    Gao Y.
    Wang H.
    Li Z.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (05): : 1949 - 1957
  • [3] Study on the partial discharge characteristics of the XLPE insulation samples during electrical treeing ageing
    Cheng, YH
    Chen, XL
    Rong, MZ
    Yue, B
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 211 - 214
  • [4] Partial Discharge Characteristics of Electrical Treeing in XLPE insulation utilizing Multi Level PWM Waveforms
    Hammarstrom, Thomas John Ake
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 4699 - 4704
  • [5] Experiment and Simulation of Temperature Effects on Partial Discharge and Electrical Treeing in XLPE Insulation
    Li, Yan
    Shan, Yu
    Zhen, Guancheng
    Lan, Lingyuan
    Liu, Yunpeng
    Zeng, Xiangrui
    Liu, Bowen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) : 674 - 683
  • [6] Electrical Treeing in XLPE Cable Insulation under Harmonic AC voltages
    Sarathi, R.
    Oza, K. H.
    Kumar, C. L. G. Pavan
    Tanaka, T.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3177 - 3185
  • [7] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1709 - +
  • [8] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1665 - 1670
  • [9] Characteristics of Partial Discharge During Electrical Treeing in XLPE Under DC Voltage
    Zhu X.
    Lin G.
    Zhang H.
    Wang Y.
    Wu J.
    Yin Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (06): : 2416 - 2426
  • [10] Electrical treeing in XLPE cable insulation at cryogenic temperature under harmonic AC voltages
    Mittal, Lakshya
    Sarathi, R.
    Sethupathi, K.
    CRYOGENICS, 2015, 71 : 62 - 67