Dosimetric Comparison of Volumetric Modulated Arc Therapy, Step-And-Shoot, and Sliding Window IMRT for Prostate Cancer

被引:0
|
作者
Schnell, Erich [1 ]
Herman, Tania De La Fuente [1 ]
Young, Julie [1 ]
Hildebrand, Kim [1 ]
Algan, Ozer [1 ]
Syzek, Elizabeth [1 ]
Herman, Terence [1 ]
Ahmad, Salahuddin [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
来源
MEDICAL PHYSICS | 2012年 / 1494卷
关键词
Prostate Cancer; Intensity Modulated Radiation Therapy; Volumetric Modulated Arc Therapy; Step and Shoot; Sliding Window; COMPLICATION PROBABILITY; BRACHYTHERAPY; IRRADIATION;
D O I
10.1063/1.4764589
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate treatment plans generated by Step-and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated and compared. The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in five out of the six patients. The results show similar target coverage in general.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 50 条
  • [41] Dosimetric comparisons of DMPO and two-step approach step-and-shoot IMRT plans
    Su, Z.
    Dogan, N.
    Wu, Y.
    Stojadinovic, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2335 - 2335
  • [42] The dosimetric accuracy of step-and-shoot IMRT for head-and-neck cancer patients in clinical routine
    Raaijmakers, C
    Astreinidou, E
    Welleweerd, J
    Terhaard, C
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S334 - S335
  • [43] Static and rotational step-and-shoot IMRT treatment plans for the prostate: A risk comparison study
    Blais, Adam Richard
    Lederer, Ernst
    Oliver, Michael
    Leszczynski, Konrad
    MEDICAL PHYSICS, 2012, 39 (02) : 1069 - 1078
  • [44] Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy
    Khan, M.
    Rehman, J.
    Khan, M.
    Chow, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 366 - 367
  • [45] Comparison of beam on time for sliding window and step and shoot IMRT treatment plans
    King, G
    Selvaraj, R
    Mogus, R
    Wu, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1271 - 1271
  • [46] IMRT for postoperative treatment of gastric cancer: Covering large target volumes in the upper abdomen: A comparison of a step-and-shoot and an ARC therapy approach
    Wieland, P
    Dobler, B
    Mai, S
    Hermann, B
    Tiefenbacher, U
    Steil, V
    Wenz, F
    Lohr, F
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1236 - 1244
  • [47] SmartArc-based volumetric modulated arc therapy can improve the middle ear, vestibule and cochlea sparing for locoregionally advanced nasopharyngeal carcinoma: a dosimetric comparison with step-and-shoot intensity-modulated radiotherapy
    Gao, J.
    Qian, T-L
    Tao, C-Z
    Zhang, Y-H
    Zhou, Y.
    Yang, J.
    He, J.
    Wang, R.
    Zhou, P-J
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053):
  • [48] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy vs Intensity Modulated Radiation Therapy for Anal Cancer
    Hibbitts, K.
    Chiang, B.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E623 - E623
  • [49] Comparison of Dosimetric Analysis of Volumetric Modulated Arc Therapy Vs Intensity Modulated Radiation Therapy for Anal Cancer
    Chiang, B.
    Hibbitts, K.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E305 - E305
  • [50] Dosimetric effects of segment MU redistribution on step-and-shoot IMRT patient dose
    Li, J
    Dempsey, J
    Zeidan, O
    Liu, C
    Palta, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1315 - 1315