Limits of internal fixation in long-bone fracture

被引:27
|
作者
Nieto, H. [1 ]
Baroan, C. [1 ]
机构
[1] Ctr Hosp Georges Renon, Serv Chirurg Orthoped, 40 Ave Charles de Gaulle, F-79021 Niort, France
关键词
Internal fixation; Locking plate; Intramedullary nailing; External fixator; Open fracture; Damage control; OPEN TIBIAL FRACTURES; PROXIMAL HUMERAL FRACTURES; EXTERNAL FIXATION; DAMAGE CONTROL; SURGICAL-TREATMENT; ELDERLY-PATIENTS; CONTROLLED-TRIAL; INFECTION-RATES; PLATE;
D O I
10.1016/j.otsr.2016.11.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Alternatives to internal fixation of long-bone fracture comprise, depending on location, external fixation or joint replacement. Limitations comprise risk of infection and functional outcome quality, which vary according to technique. The present study examines these limitations, based on comparative or large-scale studies from which certain significant results emerge. Four main questions are dealt with: (1) the present role of locking plates; (2) conditions for intramedullary nailing in Gustilo grade Mb open fracture; (3) the limitations of conversion from external fixation to intramedullary nailing in open lower leg fracture; (4) and the limitations of definitive anterograde femoral nailing in multiple trauma. Locking plate fixation has yet to prove clinical superiority in any of the anatomic sites for which good-quality comparative analyses are available. Infection risk in Gustilo grade Mb open lower leg fracture is equivalent when treated by intramedullary nailing or external fixation, if wound care and debridement are effective, antibiotherapy is initiated rapidly and skin cover is restored within 7 days. Conversion from primary external fixation to intramedullary nailing is possible if the external fixator was fitted less than 28 days previously and skin cover was restored within 7 days. The pulmonary and systemic impact of peripheral lesions or definitive anterograde intramedullary nailing of femoral fracture in multiple trauma calls for caution and what is known as "damage-control orthopedics" (DCO), a term covering the general consequences of both the initial trauma and its treatment. Femoral intramedullary nailing is thus contraindicated in case of hemorrhagic shock (blood pressure < 90 mmHg), hypothermia (< 33 degrees C), coagulation disorder (platelet count< 90,000) or peripheral lesions such as multiple long-bone fractures, crushed limb or primary pulmonary contusion. In such cases, external fixation or retrograde nailing with a small-diameter nail and without reaming are preferable. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S61 / S66
页数:6
相关论文
共 50 条
  • [41] SPIRAL TIBIAL FRACTURES OF CHILDREN - A COMMONLY ACCIDENTAL SPIRAL LONG-BONE FRACTURE
    MELLICK, LB
    REESOR, K
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1990, 8 (03): : 234 - 237
  • [42] CARDIOPULMONARY BENEFITS OF IMMEDIATE RIGID FIXATION OF LONG-BONE FRACTURES IN THE MULTIPLE TRAUMA PATIENT
    LOZMAN, J
    DENO, DC
    STRATTON, HH
    FEUSTEL, PJ
    CHANG, P
    DUTTON, RE
    SHAH, DM
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1984, 24 (07): : 668 - 668
  • [43] STRESS-ANALYSIS OF COMPRESSION PLATE FIXATION AND ITS EFFECTS ON LONG-BONE REMODELING
    CHEAL, EJ
    HAYES, WC
    WHITE, AA
    PERREN, SM
    JOURNAL OF BIOMECHANICS, 1985, 18 (02) : 141 - 150
  • [44] A 17-Year-Old Male With Hypoxemia After Long-Bone Fracture
    Seo, Chanhee
    Thornton, Christina S.
    CHEST, 2023, 164 (04) : E101 - E105
  • [45] A Surgical Robotic System for Long-Bone Fracture Alignment: Prototyping and Cadaver Study
    Saeedi-Hosseiny, Marzieh S.
    Alruwaili, Fayez
    McMillan, Sean
    Iordachita, Iulian
    Abedin-Nasab, Mohammad H.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2022, 4 (01): : 172 - 182
  • [46] The effect of platelet-rich plasma on fracture healing in long-bone pseudoarthrosis
    Basdelioglu, Koray
    Meric, Goekhan
    Sargin, Serdar
    Atik, Aziz
    Ulusal, Ali Engin
    Akseki, Devrim
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08): : 1481 - 1486
  • [47] CLINICAL-APPLICATION OF A FRACTURE DISTRACTOR IN REPAIR OF LONG-BONE INJURIES IN THE DOG
    CHAMBERS, JN
    BETTS, CW
    VETERINARY SURGERY, 1984, 13 (02) : 71 - 75
  • [48] LEUPEPTIN SPARES LIVER AND DIAPHRAGM ATROPHY AFTER LONG-BONE FRACTURE IN THE RAT
    MILLER, B
    BUCKSPAN, R
    HOXWORTH, B
    LACY, W
    ABUMRAD, N
    CLINICAL RESEARCH, 1984, 32 (02): : A404 - A404
  • [49] Pediatric obesity and traumatic lower-extremity long-bone fracture outcomes
    Backstrom, Ian C.
    MacLennan, Paul A.
    Sawyer, Jeffrey R.
    Creek, Aaron T.
    Rue, Loring W., III
    Gilbert, Shawn R.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (04): : 966 - 971
  • [50] Cerebral Fat Embolism After Traumatic Long-Bone Fracture: A Case Report
    Ippolito, Mariachiara
    Benenati, Vincenzo
    Gambino, Valentina
    Lapi, Maria
    Nicosia, Dario
    Pace, Alessandro
    Presti, Gabriele
    Ronga, Fiammetta
    Spina, Noemi
    Tutone, Marco
    Vanella, Rosaria
    Federico, Antonino
    Giarratano, Antonino
    Cortegiani, Andrea
    CLINICAL CASE REPORTS, 2024, 12 (12):