External-cavity diode laser spectrometer for measuring the concentration ratio 13CO2/12CO2 by absorptionin the range of 1.6 μm

被引:3
|
作者
Zaytsev, A. A. [1 ,2 ]
Nikolaev, I. V. [1 ]
Ochkin, V. N. [1 ]
Tskhai, S. N. [1 ]
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Moscow 119991, Russia
[2] State Univ, Moscow Inst Phys & Technol, Dolgoprudnyi 141700, Moscow Region, Russia
基金
俄罗斯基础研究基金会;
关键词
ratio of isotope concentrations; diode laser; cavity; absorption spectroscopy; ISOTOPE RATIO; CO2;
D O I
10.1070/QE2015v045n07ABEH015812
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The method for determining the carbon isotopic ratio from CO2 absorption spectra in the optical cavity containing atmospheric air with the natural contents of carbon dioxide similar to 0.03 % is described. The measurements are performed at atmospheric pressure in the conditions of overlapping absorption lines. The measurement accuracy is 0.3 %.
引用
收藏
页码:680 / 684
页数:5
相关论文
共 50 条
  • [21] Observation of CO and CO2absorption near 1.57 μm with an external-cavity diode laser
    Physical Sciences Inc., 20 New England Business Center, Andover, MA 01810-1077, United States
    Applied Optics, 1997, 36 (15): : 3298 - 3300
  • [22] 13CO2/12CO2 isotopic ratio measurements with a continuous-wave quantum cascade laser in exhaled breath
    Kasyutich, Vasili L.
    Martin, Philip A.
    INFRARED PHYSICS & TECHNOLOGY, 2012, 55 (01) : 60 - 66
  • [23] Real Time Sensing of 12CO2 and 13CO2 Using 2μm DFB-LD
    Amamoto, Kanto
    Tei, Kazuyoku
    Yamaguchi, Shigeru
    Sakai, Shunichi
    Asobe, Masaki
    Ohba, Takeshi
    2017 22ND MICROOPTICS CONFERENCE (MOC), 2017, : 210 - 211
  • [24] The ν1+5ν3 dyad of 12CO2 and 13CO2
    Campargue, A
    Bailly, D
    Teffo, JL
    Tashkun, SA
    Perevalov, VI
    JOURNAL OF MOLECULAR SPECTROSCOPY, 1999, 193 (01) : 204 - 212
  • [25] Evaluating calibration strategies for isotope ratio infrared spectroscopy for atmospheric 13CO2/12CO2 measurement
    Wen, X. -F.
    Meng, Y.
    Zhang, X. -Y.
    Sun, X. -M.
    Lee, X.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (06) : 1491 - 1501
  • [26] Observation of CO and CO2 absorption near 1.57 mu m with an external-cavity diode laser
    Sonnenfroh, DM
    Allen, MG
    APPLIED OPTICS, 1997, 36 (15): : 3298 - 3300
  • [27] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    Erdélyi, M
    Richter, D
    Tittel, FK
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 289 - 295
  • [28] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    M. Erdélyi
    D. Richter
    F.K. Tittel
    Applied Physics B, 2002, 75 : 289 - 295
  • [29] Intercomparison of two cavity ring-down spectroscopy analyzers for atmospheric 13CO2/12CO2 measurement
    Pang, Jiaping
    Wen, Xuefa
    Sun, Xiaomin
    Huang, Kuan
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (08) : 3879 - 3891
  • [30] Respiration in the light measured by 12CO2 emission in 13CO2 atmosphere in maize leaves
    Loreto, F
    Velikova, V
    Di Marco, G
    AUSTRALIAN JOURNAL OF PLANT PHYSIOLOGY, 2001, 28 (11): : 1103 - 1108