EXPERIMENTAL STUDY OF THE EVAPORATIVE COOLING SYSTEM IN A LOW-NOISE POWER TRANSFORMER

被引:0
|
作者
Niu, Wenhao [1 ,2 ]
Li, Ning [3 ]
Chen, Shuang [4 ]
Tang, Sheng [4 ]
Hu, Yongjia [4 ]
Cai, Junfeng [4 ]
Lv, Lu [4 ]
Jin, Chengxiang [3 ]
Bai, Zhongdong [3 ]
Zhong, Haifeng [1 ,2 ]
Zhang, Guoqiang [1 ]
Xu, Zihong [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing, Peoples R China
[3] China Elect Equipment Grp, Dept R&D, Beijing, Peoples R China
[4] Wuhan Elect Power Corp, SGCC, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Transformer; Fluorocarbon; Transformer cooling technology; Finned tube; Urban substations;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Decades of experience in underground substations indicated that the traditional cooling technologies have their own various shortcomings. Therefore, a novel evaporative cooling system was pointed out and will be applied in a power transformer of an urban substation. This new cooling technology could be considered as a two-step cooling system, which could transport heat energy effectively from underground thermal sources to the parallel finned tubes assembled in the transformer tank, and the evaporative coolant in parallel finned tubes absorbs heat and changes from liquid into vapor, then the vapor condenses back into liquid in the radiators on the ground. Furthermore, the cooling system is self-circulated, needing no additional pump or fans. A 2500W experimental model is designed, fabricated and tested, and the testing result shows that the top oil temperature rise meet the requirement of Chinese National Standard of GB 1094.2-1996 and the relevant IEC 60076-2-2011, which proves the feasibility of the new transformer cooling technology. Next, a transformer prototype will be fabricated and put into operation.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Study noise and low-noise circuit in the amplifier
    Liang, Yu
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture & Technology, 2000, 32 (02): : 203 - 204
  • [22] Concept of transformer-feedback degeneration of low-noise amplifiers
    Tasic, A
    Serdijn, WA
    Long, JR
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL I: ANALOG CIRCUITS AND SIGNAL PROCESSING, 2003, : 421 - 424
  • [23] A LOW-NOISE PREAMPLIFIER FILTER SYSTEM
    GIORGINIS, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03): : 563 - 574
  • [24] THE ORETICAL AND EXPERIMENTAL STUDY ON LOW-NOISE RAILS WITH LABYRINTH CONSTRAINED DAMPING
    Yin, X. J.
    Gao, X. L.
    ENVIRONMENTAL VIBRATIONS: PREDICTION, MONITORING, MITIGATION AND EVALUATION, VOLS I AND II, 2009, : 617 - 623
  • [25] Power supplies aim at low-noise applications
    不详
    IEEE SPECTRUM, 1999, 36 (05) : 74 - 75
  • [26] Experimental study on a cross-flow regenerative indirect evaporative cooling system
    Cui, Xin
    Tian, Wei
    Yang, Xiaohu
    Kong, Qiongxiang
    Chai, Yue
    Jin, Liwen
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 395 - 400
  • [27] Study of Evaporative Cooling system for Enhancement of Fuel-Cell Specific Power
    Yu, Yong Jun
    Woo, Jong Bin
    Yu, Sang Seok
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2024, 48 (11) : 709 - 720
  • [28] Experimental investigations for analyzing performance of a direct evaporative cooling system: A case study
    Vairagade, Suraj
    Bopche, Santosh
    Kanhe, Narendra
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (03) : 6078 - 6098
  • [29] Visual Experimental Study on Two Phase Flow Patterns of the Evaporative Cooling System
    Shi, Yitao
    Cao, Rui
    Ruan, Lin
    IEEE ACCESS, 2021, 9 : 9277 - 9283
  • [30] Research on the isobaric evaporative cooling system of power thyristor
    Cai, J
    Cao, HL
    Gu, GB
    IECON 2004 - 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL. 1, 2004, : 715 - 718