Glucose biosensor based on a flexible Au/ZnO film to enhance the glucose oxidase catalytic response

被引:10
|
作者
Chavez-Urbiola, I. R. [1 ]
Resendiz-Jaramillo, A. Y. [2 ]
Willars-Rodriguez, F. J. [3 ]
Martinez-Saucedo, G. [1 ]
Arriaga, L. G. [4 ]
Alcantar-Pena, Jesus [1 ]
Escalona-Villalpando, Ricardo A. [2 ]
Ledesma-Garcia, J. [2 ]
机构
[1] Ctr Ingn & Desarrollo Ind, Ave Playa Pie Cuesta 702, Santiago De Queretaro 76125, Queretaro, Mexico
[2] Univ Autonoma Queretaro, Fac Ingn, Div Invest & Posgrad, Santiago De Queretaro 76010, Mexico
[3] CINVESTAV Queretaro, Libramiento Norponiente 2000, Queretaro 76230, Mexico
[4] Ctr Invest & Desarrollo Tecnol Electroquim, Queretaro 76703, Mexico
关键词
ZnO film; Glucose biosensor; Glucose oxidase enzyme; Electron -beam evaporation; Polyamide filter -membrane; NONENZYMATIC DETECTION; OPTICAL-PROPERTIES; ZNO FILMS; NANOPARTICLES; SENSOR; IMMOBILIZATION; NANOCOMPOSITES; GOLD;
D O I
10.1016/j.jelechem.2022.116941
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work shows the influence of the isoelectric indirect effect of the semiconductor ZnO in the enzymatic immobilization in a glucose biosensor. For this purpose, thin films based on Au and Au/ZnO were synthesized on a microstructured flexible substrate of polyamide filter membrane (P.F) and characterized by FESEM and XRD. Both flexible surfaces were used to immobilize glucose oxidase (GOx) enzyme mixed with ferrocene methanol (Fc) and multiwalled carbon nanotubes (GOx-Fc/MWCNT). Subsequently, these surfaces were used as working electrodes to be evaluated as glucose biosensors. The effect of the ZnO film was compared. The performance of the flexible substrate based on Au/GOx-Fc/MWCNT and Au/ZnO/GOx-Fc/ MWCNT as glucose sensor showed similar linearity between 0 and 12 mM glucose; however a higher sensitivity (30.00 mu A mM-1 cm-2) and lower limit of detection and quantification values were obtained (0.25 mM and 0.83 mM, respectively) when ZnO thin film was used. The results suggest that the ZnO thin film in junction with GOx enzyme enhance the immobilization process of the biocatalyst, resulting in an improvement of the glucose biosensor parameters.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    Nien, Po-Chin
    Tung, Tsai-Shih
    Ho, Kuo-Chuan
    ELECTROANALYSIS, 2006, 18 (13-14) : 1408 - 1415
  • [22] Photoelectrochemical Glucose Biosensor Based on the Heterogeneous Facets of Nanocrystalline TiO2/Au/Glucose Oxidase Films
    Yang, Wenke
    Xu, Wei
    Wang, Yadong
    Chen, Delun
    Wang, Xiaohong
    Cao, Yang
    Wu, Qiang
    Tu, Jinchun
    Zhen, Chao
    ACS APPLIED NANO MATERIALS, 2020, 3 (03): : 2723 - 2732
  • [23] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the platinum electrode modified with NiO doped ZnO nanorods
    Chu, Xiangfeng
    Zhu, Xiaohua
    Dong, Yongping
    Chen, Tongyun
    Ye, Mingfu
    Sun, Wenqi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 676 : 20 - 26
  • [24] Lactate oxidase and glucose oxidase biosensor with ultra-fine Au particles
    Meng, Xian-Wei
    Gao, Feng-Tang
    Ren, Xiang-Ling
    Wei, Zheng
    Tang, Fang-Qiong
    Guocheng Gongcheng Xuebao/The Chinese Journal of Process Engineering, 2002, 2 (04):
  • [25] A Hybrid Enzyme Biosensor Based on Sulfite Oxidase and Glucose Oxidase for the Analyzing of Sulfite and Glucose
    Sezginturk, Mustafa Kemal
    Alacam, Sencer
    Altug, Cagri
    Akbayirli, Pinar
    Dinckaya, Erhan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02): : 153 - 162
  • [26] A FLEXIBLE BIOSENSOR FOR GLUCOSE
    MITSUBAYASHI, K
    DICKS, JM
    YOKOYAMA, K
    TAKEUCHI, T
    TAMIYA, E
    KARUBE, I
    ELECTROANALYSIS, 1995, 7 (01) : 83 - 87
  • [27] Whispering gallery mode resonator and glucose oxidase based glucose biosensor
    Brice, Inga
    Grundsteins, Karlis
    Atvars, Aigars
    Alnis, Janis
    Viter, Roman
    Ramanavicius, Arunas
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 318
  • [28] A glucose biosensor based on immobilization of glucose oxidase in chitosan network matrix
    Yao, H
    Li, N
    Xu, JZ
    Zhu, JJ
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (03) : 275 - 279
  • [29] Chitosan coated on the layers' glucose oxidase immobilized on cysteamine/Au electrode for use as glucose biosensor
    Zhang, Yawen
    Li, Yunqiu
    Wu, Wenjian
    Jiang, Yuren
    Hu, Biru
    BIOSENSORS & BIOELECTRONICS, 2014, 60 : 271 - 276
  • [30] Covalent attachment of glucose oxidase to an Au electrode modified with gold nanoparticles for use as glucose biosensor
    Zhang, SX
    Wang, N
    Yu, HJ
    Niu, YM
    Sun, CQ
    BIOELECTROCHEMISTRY, 2005, 67 (01) : 15 - 22