Accurate measurement of oxygen consumption in children undergoing cardiac catheterization

被引:15
|
作者
Li, Jia [1 ]
机构
[1] Univ Alberta, Div Pediat Cardiol, Stollery Childrens Hosp, Dept Pediat,Mazankowski Alberta Heart Inst, Edmonton, AB T6G 2C8, Canada
关键词
hemodynamics; pediatric interventions; complications pediatric cath/intervention; PULMONARY VASCULAR-RESISTANCE; CONGENITAL HEART-DISEASE; CARBON-DIOXIDE; CARDIOPULMONARY BYPASS; FONTAN OPERATION; SYSTEMIC HEMODYNAMICS; VENTILATED CHILDREN; TRANSPORT; INFANTS; ANESTHESIA;
D O I
10.1002/ccd.24440
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Oxygen consumption (VO2) is an important part of hemodynamics using the direct Fick principle in children undergoing cardiac catheterization. Accurate measurement of VO2 is vital. Obviously, any error in the measurement of VO2 will translate directly into an equivalent percentage under- or overestimation of blood flows and vascular resistances. It remains common practice to estimate VO2 values from published predictive equations. Among these, the LaFarge equation is the most commonly used equation and gives the closest estimation with the least bias and limits of agreement. However, considerable errors are introduced by the LaFarge equation, particularly in children younger than 3 years of age. Respiratory mass spectrometry remains the state-of-the-art method, allowing highly sensitive, rapid and simultaneous measurement of multiple gas fractions. The AMIS 2000 quadrupole respiratory mass spectrometer system has been adapted to measure VO2 in children under mechanical ventilation with pediatric ventilators during cardiac catheterization. The small sampling rate, fast response time and long tubes make the equipment a unique and powerful tool for bedside continuous measurement of VO2 in cardiac catheterization for both clinical and research purposes. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [21] Pulmonary hemorrhage in children with Alagille syndrome undergoing cardiac catheterization
    Adamson, Gregory T.
    Peng, Lynn F.
    Feinstein, Jeffrey A.
    Yarlagadda, Vamsi V.
    Lin, Amy
    Wise-Faberowski, Lisa
    McElhinney, Doff B.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (02) : 262 - 269
  • [22] MEASUREMENT OF OXYGEN-CONSUMPTION IN CHILDREN
    GREENWOOD, P
    MACARTNEY, FJ
    LINDEN, RJ
    KAPPAGODA, CT
    CLINICAL SCIENCE, 1972, 43 (06) : P16 - +
  • [23] OXYGEN-CONSUMPTION IN INFANTS AND CHILDREN DURING HEART CATHETERIZATION
    MOCELLIN, R
    MUHLSTEIN, V
    BUHLMEYER, K
    HERZ, 1980, 5 (06) : 385 - 392
  • [24] OXYGEN-CONSUMPTION IN ADULT PATIENTS DURING CARDIAC-CATHETERIZATION
    DEHMER, GJ
    FIRTH, BG
    HILLIS, LD
    CLINICAL CARDIOLOGY, 1982, 5 (08) : 436 - 440
  • [25] Front teeth-to-carina distance in children undergoing cardiac catheterization
    Hunyady, Agnes I.
    Pieters, Benjamin
    Johnston, Troy A.
    Jonmarker, Christer
    ANESTHESIOLOGY, 2008, 108 (06) : 1004 - 1008
  • [26] PATENCY OF THE INTER-ATRIAL SEPTUM IN CHILDREN UNDERGOING CARDIAC CATHETERIZATION
    WALDMAN, JD
    ROSE, G
    TURNER, SW
    PAPPELBAUM, SJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1978, 4 (04): : 427 - 431
  • [27] HEMODYNAMIC-EFFECTS OF KETAMINE IN CHILDREN UNDERGOING CARDIAC-CATHETERIZATION
    BERMAN, W
    FRIPP, RR
    RUBLER, M
    ALDERETE, L
    PEDIATRIC CARDIOLOGY, 1990, 11 (02) : 72 - 76
  • [28] DIRECT MEASUREMENT OF THE OXYGEN SATURATION OF HUMAN BLOOD DURING CARDIAC CATHETERIZATION
    ZIJLSTRA, WG
    MOOK, GA
    ARCHIVES INTERNATIONALES DE PHARMACODYNAMIE ET DE THERAPIE, 1957, 110 (2-3): : 344 - 346
  • [29] INSTANEOUS MEASUREMENT OF OXYGEN SATURATION AT CARDIAC CATHETERIZATION USING REFLECTED LIGHT
    ZIJLSTRA, WG
    MOOK, GA
    NADAS, AS
    CIRCULATION, 1957, 16 (05) : 958 - 958
  • [30] CIRCULATING MEGAKARYOCYTES AND PLATELET PRODUCTION IN CHILDREN WITH CONGENITAL CARDIAC DEFECTS UNDERGOING CARDIAC-CATHETERIZATION
    JOHNSON, CAC
    HUMAN, DG
    SACKS, RT
    MILLS, AE
    SOUTH AFRICAN MEDICAL JOURNAL, 1988, 73 (10): : 578 - 580