Object-based deformation technique for 3-D CT lung nodule detection

被引:27
|
作者
Lou, SL [1 ]
Chang, CL [1 ]
Lin, KP [1 ]
Chen, TS [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
object-based; deformation; lung nodule; computer tomography; three-dimension;
D O I
10.1117/12.348557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Helical CT scans have shown effectiveness in detecting lung nodules compared with the convention thoracic radiography. However, in a two-dimensional (2-D) image slice, it is difficult to differentiate nodules from the vertically oriented pulmonary blood vessels. This paper reports an object-based deformation method to detect lung nodules from CT images in three-dimension (3-D). Object-based deformation method in this paper consists of preprocessing and nodule detection. CT numbers are used to identify the pulmonary region and the objects of nodules, blood vessels, and airways. Hough transform is used to identify each circle shape within the pulmonary region. The circles in the different slices are then grouped into the same nodule, airway or blood to be a target object. To differentiate lung nodules from blood vessels and airways, we use a deformable seed object technique. For a given target object within the pulmonary region, the seed object grows within the target object until it is against the wall of the target object. The seed object is then deformed to match the target object. A cost function is used to match the seed object and the target object. Eight patient cases with 18 nodules were included in this study and the average size of the nodules was 2.4 cm approximately.
引用
收藏
页码:1544 / 1552
页数:9
相关论文
共 50 条
  • [41] Object-based human face detection
    Kim, HS
    Kim, EY
    Hwang, SW
    Kim, HJ
    IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - 2000 DIGEST OF TECHNICAL PAPERS, 2000, : 354 - 355
  • [42] Researches on detection of 3-D underground cave based on TEM technique
    Xue, G. Q.
    Yan, Y. J.
    Cheng, J. L.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 64 (02) : 425 - 430
  • [43] OBJECT-BASED ANALYSIS-SYNTHESIS CODING (OBASC) BASED ON THE SOURCE MODEL OF MOVING FLEXIBLE 3-D OBJECTS
    OSTERMANN, J
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (05) : 705 - 711
  • [44] Object-based Compression of 3D Animation Geometry
    Das, Sanjib
    Bora, P. K.
    2018 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS (SPCOM 2018), 2018, : 187 - 191
  • [45] An efficient pixel-based technique for visual verification of 3-D object hypotheses
    Boshra, M
    Zhang, H
    1996 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, PROCEEDINGS, VOLS 1-4, 1996, : 3472 - 3477
  • [46] 2D mesh-based detection and representation of an occluding object for object-based video
    Gökçetekin, MH
    Celasun, I
    Tekalp, AM
    2000 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS, VOLS I-VI, 2000, : 1915 - 1918
  • [47] A hybrid object-based video compression technique
    Talluri, R
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, PROCEEDINGS - VOL III, 1996, : 387 - 390
  • [48] Computer-aided lung nodule detection based on CT images
    Jia Tong
    Zhao Da-Zhe
    Wei Ying
    Zhu Xin-Hua
    Wang Xu
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 816 - 819
  • [49] Model-based segmentation architecture for lung nodule detection in CT
    Brown, MS
    Aberle, DR
    Goldin, JG
    Suh, RD
    McNitt-Gray, MF
    RADIOLOGY, 2000, 217 : 207 - 207
  • [50] Preprocessing methods for nodule detection in lung CT
    Delogu, P
    Cheran, SC
    De Mitri, I
    De Nunzio, G
    Fantacci, ME
    Fauci, F
    Gargano, G
    Torres, EL
    Massafra, R
    Oliva, P
    Martinez, AP
    Raso, G
    Retico, A
    Stumbo, S
    Tata, A
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1099 - 1103