High-field magnetic resonance imaging using solenoid radiofrequency coils

被引:5
|
作者
Vegh, Viktor [1 ]
Glaeser, Philipp [1 ]
Maillet, Donald [1 ]
Cowin, Gary J. [1 ]
Reutens, David C. [1 ]
机构
[1] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld, Australia
关键词
Micro-coil; Micron resolution; Magnetic resonance imaging; Rat kidney; RADIO-FREQUENCY COIL; NMR PROBE DESIGN; RESOLUTION; SENSITIVITY; SAMPLES; MRI;
D O I
10.1016/j.mri.2012.04.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. Image quality was quantified using signal-to-noise ratio and signal variation over regions of interest. Benchmarking was conducted using 5-mm diameter coils, as this size is comparable to an established coil of the same size. Our 1.4-mm-diameter coils were compared directly to each other, from which we deduce performance as a function of conductor material and coating. A variety of materials and conductor coatings allowed us to choose an optimal design, which we used to image a kidney section at 10-micron resolution. We applied zero-fill extrapolation to achieve 5-micron resolution. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:1177 / 1185
页数:9
相关论文
共 50 条
  • [21] Stepped Impedance Resonators for High-Field Magnetic Resonance Imaging
    Akgun, Can E.
    DelaBarre, Lance
    Yoo, Hyoungsuk
    Sohn, Sung-Min
    Snyder, Carl J.
    Adriany, Gregor
    Ugurbil, Kamil
    Gopinath, Anand
    Vaughan, J. Thomas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) : 327 - 333
  • [22] How to implement high-field intraoperative magnetic resonance imaging
    Nimsky, C
    Ganslandt, O
    Fahlbusch, R
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 139 - 143
  • [23] HIGH-FIELD MAGNETIC-RESONANCE-IMAGING OF THE RECTOSIGMOID COLON
    GREENBAUM, D
    SIERRA, A
    FOSTER, K
    LYONS, J
    POTCHEN, E
    GASTROENTEROLOGY, 1986, 90 (05) : 1437 - 1437
  • [24] Ceramic dielectric resonators for high-field magnetic resonance imaging
    Tyagi, Varun
    Semouchkina, Elena
    Lanagan, Michael
    Baker, Amanda
    Webb, Andrew
    Neuberger, Thomas
    2007 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-12, 2007, : 3903 - +
  • [25] High-Field Optical Cesium Magnetometer for Magnetic Resonance Imaging
    Staerkind, Hans
    Jensen, Kasper
    Muller, Jorg H.
    Boer, Vincent O.
    Polzik, Eugene S.
    Petersen, Esben T.
    PRX QUANTUM, 2024, 5 (02):
  • [26] Ultra High-Field Magnetic Resonance Imaging of a Glaucoma Microstent
    Allemann, Reto
    Langner, Soenke
    Witt, Martin
    Schmidt, Wolfram
    Schmitz, Klaus-Peter
    Hosten, Norbert
    Guthoff, Rudolf
    Stachs, Oliver
    CURRENT EYE RESEARCH, 2011, 36 (08) : 719 - 726
  • [27] High-field magnetic resonance imaging of the human temporal lobe
    Colon-Perez, Luis M.
    King, Michael
    Parekh, Mansi
    Boutzoukas, Angelique
    Carmona, Eduardo
    Couret, Michelle
    Klassen, Rosemary
    Mareci, Thomas H.
    Carney, Paul R.
    NEUROIMAGE-CLINICAL, 2015, 9 : 58 - 68
  • [28] Self-decoupled radiofrequency coils for magnetic resonance imaging
    Yan, Xinqiang
    Gore, John C.
    Grissom, William A.
    NATURE COMMUNICATIONS, 2018, 9
  • [29] Self-decoupled radiofrequency coils for magnetic resonance imaging
    Xinqiang Yan
    John C. Gore
    William A. Grissom
    Nature Communications, 9