Temperature and humidity transient simulation and validation in a measured house without a HVAC system

被引:20
|
作者
Martinez-Ibernon, Ana [1 ]
Aparicio-Fernandez, Carolina [2 ]
Royo-Pastor, Rafael [3 ]
Vivancos, Jose-Luis [2 ,4 ,5 ]
机构
[1] Univ Politecn Valencia, Camino Vera S-N, E-46022 Valencia, Spain
[2] Unidad Mixta Univ Politecn Valencia Univ Valencia, Ctr Reconocimiento Mol & Desarrollo Tecnol, Camino Vera S-N, Valencia 46022, Spain
[3] Univ Politecn Valencia, Inst Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
[4] CIBER BBN, Barcelona, Spain
[5] Univ Politecn Valencia, Dept Proyectos Ingn, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Modelling; Simulation; TRNSYS; TRNFlow; Water condensation; Water evaporation; Family house; INFRARED THERMOGRAPHY; CONDITIONING SYSTEM; MOISTURE TRANSFER; PERFORMANCE; HEAT; AIR; INFILTRATION; BUILDINGS; CLIMATE; LEAKAGE;
D O I
10.1016/j.enbuild.2016.08.079
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although old houses are found in the housing stock which are affected by infiltration and condensation, resulting in humid walls, software generally consider properly maintained buildings, assuming dry walls. This study, aims to simulate the effect of these pathologies under dwelling indoor conditions. The objective is to assess the reliability and accuracy of different solutions through the mass and heat transfer analogy in air and water vapour mixtures. Two different modelling settings are analysed using TRNSYS thermal simulation software, evaluating the condensation and evaporation effect of temperature and humidity in a house. Simulation results are compared with four months' worth of monitored data, and a validation procedure is presented. The method proved to be a valid assessment tool to test results reliability in aboveground building modelling. The analogy approach accuracy of the mass and heat transfer in mixture's of air and water vapour was also tested. Results can be used to help designers to optimize the humidity transfer simulation in building energy modelling. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 50 条
  • [41] A dynamic simulation study of temperature and humidity independent control system for temperate semi-humid continental monsoon climate regions
    Feng, Rong
    Han, Yang
    Wu, Jiahui
    Guo, Machao
    Xiao, Taiyang
    Cui, Hong
    Liu, Ye
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [42] A new transient simulation model and changing characteristics for circulating fluid temperature in a deepwater riserless mud recovery system
    Li, Xin
    Zhang, Jie
    Ye, Wen-Qing
    Liu, Xiao-Jie
    Sun, Xue-Feng
    OCEAN ENGINEERING, 2023, 281
  • [43] Validation of the free area method for modelling fabric air dispersion system without orifices in computational fluid dynamics simulation
    Chen, Fu-Jiang
    Wu, Qin-Yu
    Huang, Dan-Dan
    Zhang, Yun
    Lu, Wang
    Chen, Meng-Meng
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (07) : 969 - 982
  • [44] Design-operation gap caused by parameter variance in HVAC system control sequences: A simulation-based study on energy efficiency and temperature controllability
    Nomura, Akari
    Shi, Shanrui
    Miyata, Shohei
    Akashi, Yasunori
    Momota, Masashi
    Sawachi, Takao
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [45] Numerical simulation of laser-induced transient temperature field in film-substrate system by finite element method
    Xu, BQ
    Shen, ZH
    Lu, J
    Ni, XW
    Zhang, SY
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (25) : 4963 - 4968
  • [46] Heat transfer enhancement of air-concrete thermal energy storage system - CFD simulation and experimental validation under transient condition
    Manoj Praveen, V. J.
    Vigneshkumar, R.
    Karthikeyan, N.
    Gurumoorthi, A.
    Vijayakumar, R.
    Madhu, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2021, 235 (05) : 1304 - 1314
  • [47] Comparison Methods of Fuzzy Logic Control and Feed Forward Neural Network In Automatic Operating Temperature and Humidity Control System (Oyster Mushroom Farm House) Using Microcontroller
    Adhitya, R. Y.
    Ramadhan, M. A.
    Kautsar, S.
    Rinanto, N.
    Sarena, S. T.
    Munadhif, Ii
    Syai'in, Mat
    Soelistijono, R. T.
    Soeprijanto, Adi
    2016 INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND SMART DEVICES (ISESD), 2016, : 168 - 173
  • [48] Validation of Diesel Fraction Content in Heavy Oils Measured by High Temperature Simulated Distillation and Physical Vacuum Distillation by Performance of Commercial Distillation Test and Process Simulation
    Stratiev, Dicho
    Shishkova, Ivelina
    Ivanov, Mihail
    Dinkov, Rosen
    Argirov, Georgi
    Vasilev, Svetlin
    Yordanov, Dobromir
    APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [49] Indoor temperature, relative humidity and CO2 monitoring and air exchange rates simulation utilizing system dynamics tools for naturally ventilated classrooms
    Asif, Ayesha
    Zeeshan, Muhammad
    BUILDING AND ENVIRONMENT, 2020, 180
  • [50] Case study of low-temperature heating in an existing single-family house-A test of methods for simulation of heating system temperatures
    Ostergaard, Dorte Skaarup
    Svendsen, Svend
    ENERGY AND BUILDINGS, 2016, 126 : 535 - 544