Temperature and humidity transient simulation and validation in a measured house without a HVAC system

被引:20
|
作者
Martinez-Ibernon, Ana [1 ]
Aparicio-Fernandez, Carolina [2 ]
Royo-Pastor, Rafael [3 ]
Vivancos, Jose-Luis [2 ,4 ,5 ]
机构
[1] Univ Politecn Valencia, Camino Vera S-N, E-46022 Valencia, Spain
[2] Unidad Mixta Univ Politecn Valencia Univ Valencia, Ctr Reconocimiento Mol & Desarrollo Tecnol, Camino Vera S-N, Valencia 46022, Spain
[3] Univ Politecn Valencia, Inst Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
[4] CIBER BBN, Barcelona, Spain
[5] Univ Politecn Valencia, Dept Proyectos Ingn, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Modelling; Simulation; TRNSYS; TRNFlow; Water condensation; Water evaporation; Family house; INFRARED THERMOGRAPHY; CONDITIONING SYSTEM; MOISTURE TRANSFER; PERFORMANCE; HEAT; AIR; INFILTRATION; BUILDINGS; CLIMATE; LEAKAGE;
D O I
10.1016/j.enbuild.2016.08.079
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although old houses are found in the housing stock which are affected by infiltration and condensation, resulting in humid walls, software generally consider properly maintained buildings, assuming dry walls. This study, aims to simulate the effect of these pathologies under dwelling indoor conditions. The objective is to assess the reliability and accuracy of different solutions through the mass and heat transfer analogy in air and water vapour mixtures. Two different modelling settings are analysed using TRNSYS thermal simulation software, evaluating the condensation and evaporation effect of temperature and humidity in a house. Simulation results are compared with four months' worth of monitored data, and a validation procedure is presented. The method proved to be a valid assessment tool to test results reliability in aboveground building modelling. The analogy approach accuracy of the mass and heat transfer in mixture's of air and water vapour was also tested. Results can be used to help designers to optimize the humidity transfer simulation in building energy modelling. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 50 条
  • [1] Multipoint Wireless Humidity and Temperature Monitoring Network for HVAC Systems Validation
    Zbiec, Michal
    Obrebski, Dariusz
    PROCEEDINGS OF 2020 27TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEM (MIXDES), 2020, : 260 - 265
  • [2] Modeling and Simulation of the Transient Response of Temperature and Relative Humidity Sensors with and without Protective Housing
    Oliveira Rocha, Keller Sullivan
    Martins, Jose Helvecio
    Martins, Marcio Aredes
    Ferrei Tinoca, Ilda De Fatima
    Osorio Saraz, Jairo Alexander
    Lacerda Filho, Adilio Flauzino
    Martins Fernandes, Luiz Henrique
    PLOS ONE, 2014, 9 (05):
  • [3] A novel numerical method of transient temperature simulation for a HVAC room
    Lv, Qian
    Yu, Xiaoling
    Ding, Yifeng
    Yang, Shuo
    Jiang, Liming
    Jia, Xiaofei
    Jin, Liwen
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 419 - 424
  • [4] Development, Calibration, and Validation of a Simulation Model for Indoor Temperature Prediction and HVAC System Fault Detection
    Palaic, Darko
    Stajduhar, Ivan
    Ljubic, Sandi
    Wolf, Igor
    BUILDINGS, 2023, 13 (06)
  • [5] The Simulation of the Temperature and the Humidity Measurement System
    Bogdan, Mihai
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING, 2016, : 241 - 245
  • [6] Investigation of Temperature and Humidity Control System for Mushroom House
    Abd Wahab, Hanani
    Manap, Muhamad Zariq Imran Abdul
    Ismail, Al Emran
    Pauline, Ong
    Ismon, Maznan
    Zainulabidin, Muhd Hafeez
    Noor, Fazimah Mat
    Mohamad, Zaleha
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (06): : 27 - 37
  • [7] An Improved Intelligent Control System for Temperature and Humidity in a Pig House
    Jin, Hua
    Meng, Gang
    Pan, Yuanzhi
    Zhang, Xing
    Wang, Changda
    AGRICULTURE-BASEL, 2022, 12 (12):
  • [8] Simulation of intermittent transient cooling load characteristic in an academic building with centralized HVAC system
    Bhaskoro, Petrus Tri
    Gilani, Syed Ihtsham Ul Haq
    Bin Aris, Mohd Shiraz
    ENVIRONMENT SCIENCE AND ENGINEERING, 2011, 8 : 291 - 296
  • [9] Modeling and Simulation of the Transient Response of Temperature and Relative Humidity Sensors with and without Protective Housing (vol 9, e95874, 2014)
    Rocha, K. S. O.
    Martins, J. H.
    Martins, M. A.
    Tinoco, Ferreira I. D. F.
    Saraz, J. A. O.
    PLOS ONE, 2014, 9 (06):
  • [10] An expert system for the humidity and temperature control in HVAC systems using ANFIS and optimization with Fuzzy Modeling Approach
    Soyguder, Servet
    Alli, Hasan
    ENERGY AND BUILDINGS, 2009, 41 (08) : 814 - 822