Performance of Iterative Image Reconstruction in CT of the Paranasal Sinuses: A Phantom Study

被引:53
|
作者
Schulz, B. [1 ]
Beeres, M. [1 ]
Bodelle, B. [1 ]
Bauer, R. [1 ]
Al-Butmeh, F. [1 ]
Thalhammer, A. [1 ]
Vogl, T. J. [1 ]
Kerl, J. M. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
DOSE REDUCTION; QUALITY; ANGIOGRAPHY; ALGORITHM;
D O I
10.3174/ajnr.A3339
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT in low dose technique is the criterion standard imaging modality for evaluation of the paranasal sinus. Our aim was to evaluate the dose-reduction potential of a recently available sinogram-affirmed iterative reconstruction technique, regarding noise, image quality, and time duration when evaluating this region. MATERIALS AND METHODS: CT was performed on a phantom head at different tube voltages (120 kV, 100 kV) and currents (100 mAs, 50 mAs, 25 mAs). Each protocol was reconstructed (in soft tissue and bony kernel) by using standard filtered back-projection and 5 different SAFIRE strengths, and image noise was evaluated. Subjective image quality was evaluated on noise-aligned image triplets acquired at tube currents of 100% (FBP), 50% (SAFIRE), and 25% (SAFIRE) by using a 5-point scale (1 = worst, 5 = best). The time duration for image reconstruction was noted for calculations with FBP and SAFIRE. RESULTS: SAFIRE reduced image noise by 15%-85%, depending on the iterative strength, rendering kernel, and dose parameters. Noise reduction was stronger at a bone kernel algorithm both in 1- and 3-mm images (P < .05). Subjective quality evaluation of the noise-adapted images showed preference for those acquired at 100% tube current with FBP (4.7-5.0) versus 50% dose with SAFIRE (3.4-4.4) versus 25% dose with SAFIRE (2.0-3.1). The time duration for FBP image sets was 2.9-6.6 images per second versus SAFIRE with 0.9-1.6 images per second. CONCLUSIONS: For CT of the paranasal sinus, SAFIRE algorithms are suitable for image-noise reduction. Because image quality decreases with dosage, careful choice of the appropriate iterative method is necessary to achieve an optimal balance between image noise and quality.
引用
收藏
页码:1072 / 1076
页数:5
相关论文
共 50 条
  • [41] Iterative Image Reconstruction with Variable Resolution in CT
    Zhang, Zheng
    Bian, Junguo
    Han, Xiao
    Pearson, Erik
    Sidky, Emil Y.
    Pan, Xiaochuan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4155 - 4157
  • [42] Iterative image reconstruction in spectral-CT
    Hernandez, Daniel
    Michel, Eric
    Kim, Hye S.
    Kim, Jae G.
    Han, Byung H.
    Cho, Min H.
    Lee, Soo Y.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [43] Techniques in Iterative Proton CT Image Reconstruction
    Penfold S.
    Censor Y.
    Sensing and Imaging, 2015, 16 (1):
  • [44] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987
  • [45] A biological phantom for evaluation of CT image reconstruction algorithms
    Cammin, J.
    Fung, G. S. K.
    Fishman, E. K.
    Siewerdsen, J. H.
    Stayman, J. W.
    Taguchi, K.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [46] Integrated phantom and efficient image reconstruction for cardiac ct
    Department of Biomedical Engineering, School of Computer, Beijing Jiaotong University, Beijing 100044, China
    Xitong Fangzhen Xuebao, 2008, 16 (4417-4420):
  • [47] Limited axial CT of the paranasal sinuses in screening for sinusitis
    Witte, RJ
    Heurter, JV
    Orton, DF
    Hahn, FJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) : 1313 - 1315
  • [48] Axial verses coronal CT scanning of the paranasal sinuses
    Bernhardt, TM
    Rapp-Bernhardt, U
    Reichel, G
    Grote, R
    RADIOLOGY, 1998, 209P : 274 - 274
  • [49] Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study
    Atsushi Nakamoto
    Yoshikazu Tanaka
    Hiroshi Juri
    Go Nakai
    Shushi Yoshikawa
    Yoshifumi Narumi
    European Radiology, 2017, 27 : 2995 - 3003
  • [50] Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study
    Nakamoto, Atsushi
    Tanaka, Yoshikazu
    Juri, Hiroshi
    Nakai, Go
    Yoshikawa, Shushi
    Narumi, Yoshifumi
    EUROPEAN RADIOLOGY, 2017, 27 (07) : 2995 - 3003