X-ray absorption tomography employing a conical shell beam

被引:0
|
作者
Evans, J. P. O. [1 ]
Godber, S. X. [2 ]
Elarnaut, F. [1 ]
Downes, D. [1 ]
Dicken, A. J. [1 ]
Rogers, K. D. [3 ]
机构
[1] Nottingham Trent Univ, Imaging Sci Grp, Rosalind Franklin Bldg, Nottingham, England
[2] MediCity, Halo Xray Technol, Nottingham, England
[3] Cranfield Univ, Cranfield Forens Inst, Swindon, Wilts, England
来源
OPTICS EXPRESS | 2016年 / 24卷 / 25期
关键词
TOMOSYNTHESIS;
D O I
10.1364/OE.24.029054
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate depth-resolved absorption imaging by scanning an object through a conical shell of X-rays. We measure ring shaped projections and apply tomosynthesis to extract optical sections at different axial focal plane positions. Three-dimensional objects have been imaged to validate our theoretical treatment. The novel principle of our method is scalable with respect to both scan size and X-ray energy. A driver for this work is to complement previously reported methods concerning the measurement of diffracted X-rays for structural analysis. The prospect of employing conical shell beams to combine both absorption and diffraction modalities would provide enhanced analytical utility and has many potential applications in security screening, process control and diagnostic imaging. (C) 2016 Optical Society of America
引用
收藏
页码:29049 / 29060
页数:12
相关论文
共 50 条
  • [21] X-RAY FAN-BEAM LUMINESCENCE TOMOGRAPHY
    Cong, Wenxiang
    Wang, Ge
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 1164 - 1167
  • [22] Cone-beam x-ray tomography with arbitrary-orientation x-ray tube
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1631 - 1634
  • [23] X-ray absorption and X-ray diffraction micro tomography of biodegradable polymer based composites
    Jaroszewicz, J.
    Idaszek, J.
    Vanmeert, F.
    Janssens, K.
    Bonnin, A.
    Swieszkowski, W.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 318 - 319
  • [24] Cone-beam X-ray tomography with arbitrary-orientation X-ray ribe
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1300 - +
  • [25] Application of x-ray image magnifier and demagnifier to parallel beam x-ray computed tomography
    Hirano, K.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (05)
  • [26] X-RAY ABSORPTION COEFFICIENTS AND GEOMETRICAL COLLIMATION OF THE BEAM
    PARRATT, LG
    PORTEUS, JO
    SCHNOPPER, HW
    WATANABE, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (05): : 344 - 347
  • [28] X-ray absorption of gold nanoparticles with thin silica shell
    Park, Yeon-Su
    Liz-Marzan, Luis M.
    Kasuya, Atsuo
    Kobayashi, Yoshio
    Nagao, Daisuke
    Konno, Mikio
    Mamykin, Sergiy
    Dmytruk, Andriy
    Takeda, Motohiro
    Ohuchi, Noriaki
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (11) : 3503 - 3506
  • [29] Characterization of core/shell nanoparticles by X-ray absorption spectroscopy
    Calvin, S
    Carpenter, EE
    Stroud, RM
    Harris, VG
    NANOTECH 2003, VOL 3, 2003, : 82 - 85
  • [30] Operando investigation of the lithium/sulfur battery system by coupled X-ray absorption tomography and X-ray diffraction computed tomography
    Tonin, Guillaume
    Vaughan, Gavin B. M.
    Bouchet, Renaud
    Alloin, Fannie
    Di Michiel, Marco
    Barchasz, Celine
    JOURNAL OF POWER SOURCES, 2020, 468 (468)