Direct-contact condensation heat transfer on downcommerless trays for steam-water system

被引:13
|
作者
Genic, SB [1 ]
机构
[1] Univ Belgrade, Fac Mech Engn, Dept Proc Engn, Belgrade 11000, Serbia Monteneg
关键词
heat transfer; direct-contact condensation; downcommerless tray; number of transfer units; kinetic energy parameter;
D O I
10.1016/j.ijheatmasstransfer.2005.10.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper deals with some of the results obtained during experimental research of the direct-contact condensation in cascade column. Downcommerless trays were used to obtain contact between water and steam in DN 300 column and experimental work included 198 runs at atmospheric pressure. Since no equation for the intensity of heat transfer was found in the open literature, original equation was established in the following form NTUL = f(F-LG) where NTUL is number of transfer units for liquid phase and F-LG is two phase kinetic energy parameter. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1225 / 1230
页数:6
相关论文
共 50 条
  • [21] Steam entrainment and heat transfer characteristic of steam submerged jet condensation within steam-water mixture layer
    Zhao, Quanbin
    Fu, Pengfei
    Chong, Daotong
    Chen, Weixiong
    Liu, Jiping
    Yan, Junjie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [22] LOCAL HEAT-TRANSFER COEFFICIENTS FOR CONDENSATION IN STRATIFIED COUNTERCURRENT STEAM-WATER FLOWS
    KIM, HJ
    BANKOFF, SG
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1983, 105 (04): : 706 - 712
  • [23] STEAM BUBBLING REGIMES AND DIRECT CONTACT CONDENSATION HEAT-TRANSFER IN HIGHLY SUBCOOLED WATER
    JEJE, A
    ASANTE, B
    ROSS, B
    CHEMICAL ENGINEERING SCIENCE, 1990, 45 (03) : 639 - 650
  • [24] Measurement of heat transfer coefficient for direct-contact condensation during bubble growth in liquid
    Department of Applied Chemistry, Keio University, Yokohama 223-8522, Japan
    J. Chem. Eng. Jpn., 5 (594-599):
  • [25] DIRECT-CONTACT HEAT-TRANSFER FOR AIR BUBBLING THROUGH WATER
    GHAZI, HS
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1991, 113 (02): : 71 - 74
  • [26] Direct-contact heat transfer for process technologies
    Jacobs, H.R.
    Journal of Heat Transfer, 1988, 110 (04):
  • [27] DIRECT-CONTACT STEAM CONDENSATION WITH SIMULTANEOUS NONCONDENSABLE GAS-ABSORPTION
    BONTOZOGLOU, V
    KARABELAS, AJ
    AICHE JOURNAL, 1995, 41 (02) : 241 - 250
  • [28] HEAT TRANSFER CRISIS WITH STEAM-WATER MIXTURES
    BERTOLET.S
    GASPARI, GP
    LOMBARDI, C
    PETERLON.G
    SILVESTR.M
    TACCONI, FA
    ENERGIA NUCLEARE, 1965, 12 (03): : 121 - &
  • [29] Numerical study on direct-contact condensation of vapor in cold water
    Takase, K
    Ose, Y
    Kunugi, T
    FUSION ENGINEERING AND DESIGN, 2002, 63-64 : 421 - 428
  • [30] CFD based approach for modeling steam-water direct contact condensation in subcooled water flow in a tee junction
    Li, S. Q.
    Wang, P.
    Lu, T.
    PROGRESS IN NUCLEAR ENERGY, 2015, 85 : 729 - 746