Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

被引:2
|
作者
Wu, T. C. [1 ]
Shi, T. [1 ]
Jovanovic, I [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Composite heterogeneous scintillator; Fast neutron detection; Pulse shape discrimination; LITHIUM-GLASS; NEUTRON;
D O I
10.1016/j.nima.2020.164265
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject gamma rays. We measure the time dependence of light output from a scintillator composed of Li-6-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to gamma rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of Li-6 glass has on gamma rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. The developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-off between neutron capture efficiency and gamma-ray rejection.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Thallium strontium iodide: A high efficiency scintillator for gamma-ray detection
    Hawrami, R.
    Ariesanti, E.
    Buliga, V.
    Burger, A.
    OPTICAL MATERIALS, 2020, 100
  • [42] MERCURIC IODIDE PHOTODETECTOR CESIUM IODIDE SCINTILLATOR GAMMA-RAY SPECTROMETERS
    MARKAKIS, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 356 - 359
  • [43] Pulse-shape analysis of Cs2LiYCl6:Ce scintillator for neutron and gamma-ray discrimination
    Lee, D. W.
    Stonehill, L. C.
    Klimenko, A.
    Terry, J. R.
    Tornga, S. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 1 - 5
  • [44] PULSE SHAPE CHARACTERISTICS OF A GE(LI) DETECTOR STUDIED WITH A COLLMATED GAMMA-RAY BEAM
    SCHMIDTWHITLEY, RD
    NUCLEAR INSTRUMENTS & METHODS, 1969, 70 (02): : 227 - +
  • [45] GAMMA-RAY EMISSION FROM MULTISTEP COMPOUND REACTIONS
    OBLOZINSKY, P
    CHADWICK, MB
    PHYSICAL REVIEW C, 1990, 42 (04): : 1652 - 1664
  • [46] COMPOSITE DIRECTIONAL GAMMA-RAY SCINTILLATION DETECTOR
    PETR, I
    ADAMS, A
    BIRKS, JB
    NUCLEAR INSTRUMENTS & METHODS, 1972, 99 (02): : 285 - &
  • [47] SCATTERED FLUX WITH GAMMA-RAY IRRADIATION OF HETEROGENEOUS MEDIA
    KIRDIN, AI
    LAZURIK, VT
    SOVIET ATOMIC ENERGY, 1987, 62 (02): : 164 - 166
  • [48] Gamma-ray pulse tube cooler development and testing
    Ross, RG
    Johnson, DL
    Metzger, A
    Kotsubo, V
    Evtimov, B
    Olson, J
    Nast, T
    Rawlings, RM
    CRYOCOOLERS 11, 2001, : 155 - 162
  • [49] TESTING THE GAMMA-RAY BURST PULSE START CONJECTURE
    Hakkila, Jon
    Nemiroff, Robert J.
    ASTROPHYSICAL JOURNAL, 2009, 705 (01): : 372 - 385
  • [50] Gamma-Ray Burst pulse spectra observed by BATSE
    Ryde, F
    Svensson, R
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1999, 39 (1-6) : 737 - 740