Improved kinetic model for the transcutaneous measurement of glomerular filtration rate in experimental animals

被引:37
|
作者
Friedemann, Jochen [1 ,2 ,3 ,4 ]
Heinrich, Ralf [5 ]
Shulhevich, Yury [1 ,2 ,3 ,4 ]
Raedle, Matthias [1 ,2 ,3 ]
William-Olsson, Lena [6 ]
Pill, Johannes [4 ]
Schock-Kusch, Daniel [1 ,2 ,3 ,4 ]
机构
[1] Mannheim Univ Appl Sci, Inst Proc Control & Innovat Energy Convers PI, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[2] Heidelberg Univ, Inst Med Technol, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[3] Univ Appl Sci Mannheim, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[4] Mannheim Pharma & Diagnost GmbH, Mannheim, Germany
[5] Freudenberg New Technol SE, Weinheim, Germany
[6] AstraZeneca R&D, Biosci CKD Gothenburg, Molndal, Sweden
关键词
FITC-sinistrin; glomerular filtration rate; transcutaneous; FITC-SINISTRIN; RENAL-FUNCTION;
D O I
10.1016/j.kint.2016.07.024
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Transcutaneous measurement of the glomerular filtration rate ((t)GFR) is now frequently used in animal studies. (t)GFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics. In contrast to standard 1- to 3-compartment models, our model covers the complete kinetic, including injection and distribution of the tracer in the plasma compartment. Because the model describes the complete progression of the measurement, it allows further refinement by correcting for baseline shifts observed occasionally during measurement. Possible reasons for shifts in the background signal include photo bleaching of the skin, autofluorescence, changes of physiological state of the animals during the measurements, or effects arising from the attachment of the measurement device. Using the new 3-compartment kinetic model with modulated baseline ((t)GFR(3cp.b.m)), (t)GFR measurements in rats can reach comparable precision as those from GFR measurements assessed using a gold standard technique based on constant infusion of a tracer. Moreover, the variability of simultaneous (parallel) measurements, as well as repeated (t)GFR measurements in the same animals, showed higher precision when (t)GFR(3cp.b.m) was compared with the 1 compartment (t)GFR(1cp) model.
引用
收藏
页码:1377 / 1385
页数:9
相关论文
共 50 条
  • [31] Transdermal Measurement of Glomerular Filtration Rate in Mice
    Scarfe, Lauren
    Schock-Kusch, Daniel
    Ressel, Lorenzo
    Friedemann, Jochen
    Shulhevich, Yury
    Murray, Patricia
    Wilm, Bettina
    de Caestecker, Mark
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (140):
  • [32] MEASUREMENT OF GLOMERULAR-FILTRATION RATE - REPLY
    RUSSELL, CD
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (10) : 1646 - 1647
  • [33] MEASUREMENT OF GLOMERULAR FILTRATION-RATE - REPLY
    COLE, BR
    GIANGIAC.J
    INGELFIN.JR
    ROBSON, AM
    NEW ENGLAND JOURNAL OF MEDICINE, 1973, 289 (02): : 106 - 107
  • [34] ACCURATE MEASUREMENT OF GLOMERULAR-FILTRATION RATE
    MULHERN, JG
    PERRONE, RD
    INTERNATIONAL YEARBOOK OF NEPHROLOGY, 1991, : 277 - 290
  • [35] Measurement and Estimation of Glomerular Filtration Rate in Children
    Mian, Ayesa N.
    Schwartz, George J.
    ADVANCES IN CHRONIC KIDNEY DISEASE, 2017, 24 (06) : 348 - 356
  • [36] MEASUREMENT OF GLOMERULAR FILTRATION RATE IN PREMATURE INFANTS
    BARNETT, HL
    HARE, K
    MCNAMARA, H
    HARE, R
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1949, 77 (01): : 113 - 113
  • [37] Glomerular Filtration Rate Measurement and Chemotherapy Dosing
    Rosner, Mitchell H.
    Sprangers, Ben
    Sandhu, Geeta
    Malyszko, Jolanta
    SEMINARS IN NEPHROLOGY, 2022, 42 (06)
  • [38] MEASUREMENT OF GLOMERULAR FILTRATION RATE IN PREMATURE INFANTS
    BARNETT, HL
    HARE, K
    MCNAMARA, H
    HARE, R
    JOURNAL OF CLINICAL INVESTIGATION, 1948, 27 (06): : 691 - 699
  • [39] Measurement of Glomerular Filtration Rate in Patients Undergoing Renal Surgery for Cancer: Estimated Glomerular Filtration Rate versus Measured Glomerular Filtration Rate in the Era of Precision Medicine
    Trevisani, Francesco
    Simeoni, Mariadelina
    Bettiga, Arianna
    Cinque, Alessandra
    Floris, Matteo
    KIDNEY & BLOOD PRESSURE RESEARCH, 2024, 49 (01): : 336 - 344
  • [40] Cystatin C: An improved estimator of glomerular filtration rate?
    Laterza, OF
    Price, CP
    Scott, MG
    CLINICAL CHEMISTRY, 2002, 48 (05) : 699 - 707