Improved kinetic model for the transcutaneous measurement of glomerular filtration rate in experimental animals

被引:37
|
作者
Friedemann, Jochen [1 ,2 ,3 ,4 ]
Heinrich, Ralf [5 ]
Shulhevich, Yury [1 ,2 ,3 ,4 ]
Raedle, Matthias [1 ,2 ,3 ]
William-Olsson, Lena [6 ]
Pill, Johannes [4 ]
Schock-Kusch, Daniel [1 ,2 ,3 ,4 ]
机构
[1] Mannheim Univ Appl Sci, Inst Proc Control & Innovat Energy Convers PI, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[2] Heidelberg Univ, Inst Med Technol, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[3] Univ Appl Sci Mannheim, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[4] Mannheim Pharma & Diagnost GmbH, Mannheim, Germany
[5] Freudenberg New Technol SE, Weinheim, Germany
[6] AstraZeneca R&D, Biosci CKD Gothenburg, Molndal, Sweden
关键词
FITC-sinistrin; glomerular filtration rate; transcutaneous; FITC-SINISTRIN; RENAL-FUNCTION;
D O I
10.1016/j.kint.2016.07.024
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Transcutaneous measurement of the glomerular filtration rate ((t)GFR) is now frequently used in animal studies. (t)GFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics. In contrast to standard 1- to 3-compartment models, our model covers the complete kinetic, including injection and distribution of the tracer in the plasma compartment. Because the model describes the complete progression of the measurement, it allows further refinement by correcting for baseline shifts observed occasionally during measurement. Possible reasons for shifts in the background signal include photo bleaching of the skin, autofluorescence, changes of physiological state of the animals during the measurements, or effects arising from the attachment of the measurement device. Using the new 3-compartment kinetic model with modulated baseline ((t)GFR(3cp.b.m)), (t)GFR measurements in rats can reach comparable precision as those from GFR measurements assessed using a gold standard technique based on constant infusion of a tracer. Moreover, the variability of simultaneous (parallel) measurements, as well as repeated (t)GFR measurements in the same animals, showed higher precision when (t)GFR(3cp.b.m) was compared with the 1 compartment (t)GFR(1cp) model.
引用
收藏
页码:1377 / 1385
页数:9
相关论文
共 50 条
  • [1] Transcutaneous measurement of glomerular filtration rate in conscious laboratory animals: State of the art and future perspectives
    Schock-Kusch, D.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2017, 390 : S87 - S87
  • [2] Transcutaneous Measurement of Glomerular Filtration Rate in conscious laboratory Animals: State of the Art and Future Perspectives
    Friedemann, Jochen
    Schock-Kusch, Daniel
    Shulhevich, Yury
    REPORTERS, MARKERS, DYES, NANOPARTICLES, AND MOLECULAR PROBES FOR BIOMEDICAL APPLICATIONS IX, 2017, 10079
  • [3] Establishment of transcutaneous measurement of the glomerular filtration rate in FVB/mice
    Enggaard, Camilla
    Bach, Marie Lykke
    Svenningsen, Per
    Jensen, Boye L.
    ACTA PHYSIOLOGICA, 2023, 239
  • [4] Transcutaneous glomerular filtration rate measurement in a canine animal model of chronic kidney disease
    Mondritzki, Thomas
    Steinbach, Sarah M. L.
    Boehme, Philip
    Hoffmann, Jessica
    Kullmann, Maximilian
    Schock-Kusch, Daniel
    Vogel, Julia
    Kolkhof, Peter
    Sandner, Peter
    Bischoff, Erwin
    Hueser, Joerg
    Dinh, Wilfried
    Truebel, Hubert
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2018, 90 : 7 - 12
  • [5] Transcutaneous Assessment of Glomerular Filtration Rate
    Geraci, Stefania
    Herrera-Perez, Zeneida
    Huang, Jianguo
    Weinfurter, Stefanie
    Neudecker, Sabine
    Shulhevich, Yury
    Friedemann, Jochen
    Pill, Johannes
    Gretz, Norbert
    PHEALTH 2014, 2014, 200 : 105 - 110
  • [6] RAPID MEASUREMENT OF GLOMERULAR-FILTRATION RATE IN SMALL ANIMALS
    IDO, Y
    TILTON, RG
    CHANG, K
    PUGLIESE, G
    WILLIAMSON, JR
    KIDNEY INTERNATIONAL, 1992, 41 (02) : 435 - 439
  • [7] Transcutaneous measurement of glomerular filtration rate using FITC-sinistrin in rats
    Schock-Kusch, Daniel
    Sadick, Maliha
    Henninger, Nadja
    Kraenzlin, Bettina
    Claus, Guenter
    Kloetzer, Hans-Martin
    Weiss, Christel
    Pill, Johannes
    Gretz, Norbert
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (10) : 2997 - 3001
  • [8] Transcutaneous measurement of glomerular filtration rate in small rodents: Through the skin for the win?
    Ellery, Stacey J.
    Cai, Xiaochu
    Walker, David D.
    Dickinson, Hayley
    Kett, Michelle M.
    NEPHROLOGY, 2015, 20 (03) : 117 - 123
  • [9] Measurement of Glomerular Filtration Rate
    Mulhern, Jeffrey G.
    Perrone, Ronald D.
    SEMINARS IN NUCLEAR MEDICINE, 2022, 52 (04) : 453 - 466
  • [10] Measurement of glomerular filtration rate
    Gaspari, F
    PerIco, N
    Remuzzi, G
    KIDNEY INTERNATIONAL, 1997, : S151 - S154