Implant design and interface force transfer - A photoelastic and strain-gauge analysis

被引:116
|
作者
Cehreli, M
Duyck, J
De Cooman, M
Puers, R
Naert, I
机构
[1] Catholic Univ Louvain, BIOMAT Res Grp, Dept Prosthet Dent, B-3000 Louvain, Belgium
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[3] Catholic Univ Louvain, Dept Electrotech EAST MICAS, B-3000 Louvain, Belgium
关键词
biomechanics; implant design; oral implants; photoelastic stress analysis; strain-gauge analysis;
D O I
10.1111/j.1600-0501.2004.00979.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare stress and strain magnitudes of butt-joint and internal-cone oral implants in a bone simulant. Material and methods: Photoelastic and strain-gauged models of solitary Branemark((R)), ITI(R) and Astra Tech((R)) implants were obtained. Vertical and 20degrees oblique forces of 100 and 150 N were applied on the abutments in separate load cases. Isochromatic fringe patterns around implants were observed and photographed in the field of a polariscope. Strain-gauge measurements were performed and principal strains induced around implants were calculated. Results: Isochromatic fringe orders of all designs were similar under both loading conditions (P>0.05). Strains around Branemark((R)) implants were lower than around Astra Tech((R)) and ITI(R) implants, particularly under vertical loads. The latter implants had similar strain magnitudes (P>0.05), although strains around the conical Astra Tech((R)) implant were lower under vertical load. Conclusions: Butt-joint and internal-cone oral implants have similar force distribution characteristics. The implant-abutment mating design is not a decisive factor affecting stress and strain magnitudes in a bone simulant.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [31] FIBER OPTIC STRAIN-GAUGE MAY INFLUENCE OIL TANKER DESIGN
    TULLOCH, MH
    PHOTONICS SPECTRA, 1995, 29 (01) : 18 - 18
  • [32] Force measurement using strain-gauge balance in a shock tunnel with long test duration
    Wang, Yunpeng
    Liu, Yunfeng
    Luo, Changtong
    Jiang, Zonglin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [33] Force measurement using strain-gauge balance in shock tunnel based on deep learning
    Shaojun NIE
    Yunpeng WANG
    Zonglin JIANG
    Chinese Journal of Aeronautics, 2023, 36 (08) : 43 - 53
  • [34] Nonlinear In-situ Calibration of Strain-Gauge Force/Torque Sensors for Humanoid Robots
    Mohamed, Hosameldin Awadalla Omer
    Nava, Gabriele
    Vanteddu, Punith Reddy
    Braghin, Francesco
    Pucci, Daniele
    2023 IEEE-RAS 22ND INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS, HUMANOIDS, 2023,
  • [35] Force measurement using strain-gauge balance in shock tunnel based on deep learning
    Nie, Shaojun
    Wang, Yunpeng
    Jiang, Zonglin
    CHINESE JOURNAL OF AERONAUTICS, 2023, 36 (08) : 43 - 53
  • [36] Force measurement using strain-gauge balance in shock tunnel based on deep learning
    Shaojun NIE
    Yunpeng WANG
    Zonglin JIANG
    Chinese Journal of Aeronautics , 2023, (08) : 43 - 53
  • [37] COMPARABILITY OF FORCE MEASUREMENTS OBTAINED WITH DIFFERENT STRAIN-GAUGE HAND-HELD DYNAMOMETERS
    BOHANNON, RW
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1993, 18 (04): : 564 - 567
  • [38] CAPILLARY FILTRATION MEASUREMENT BY STRAIN-GAUGE .1. ANALYSIS OF METHODS
    KATZ, MA
    AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (04): : H354 - H360
  • [39] STRAIN-GAUGE TECHNIQUES - PRACTICAL TOOLS FOR RESEARCH, DESIGN, PRODUCTION AND MAINTENANCE ENGINEERS
    不详
    ENGINEERING MATERIALS AND DESIGN, 1977, 21 (02): : 57 - 62
  • [40] Finite element analysis and strain-gauge studies of vertical root fracture
    Lertchirakarn, V
    Palamara, JEA
    Messer, HH
    JOURNAL OF ENDODONTICS, 2003, 29 (08) : 529 - 534