Tomotherapy - a different way of dose delivery in radiotherapy

被引:18
|
作者
Piotrowski, Tomasz [1 ,2 ]
Skorska, Malgorzata [1 ]
Jodda, Agata [1 ]
Ryczkowski, Adam [1 ]
Kazmierska, Joanna [2 ,3 ]
Adamska, Krystyna [4 ]
Karczewska-Dzionk, Aldona [5 ]
Zmijewska-Tomczak, Malgorzata [6 ]
Wlodarczyk, Hanna [7 ]
机构
[1] Greater Poland Canc Ctr, Dept Med Phys, Poznan, Poland
[2] Poznan Univ Med Sci, Dept Electroradiol, Poznan, Poland
[3] Greater Poland Canc Ctr, Dept Radiotherapy 2, Poznan, Poland
[4] Greater Poland Canc Ctr, Radiotherapy Ward 2, Poznan, Poland
[5] Greater Poland Canc Ctr, Radiotherapy Ward 3, Poznan, Poland
[6] Greater Poland Canc Ctr, Dept Radiotherapy 1, Poznan, Poland
[7] Greater Poland Canc Ctr, Gynaecol Radiotherapy Ward, Poznan, Poland
来源
WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY | 2012年 / 16卷 / 01期
关键词
helical tomotherapy; IMRT; treatment planning; evaluation of the dose distribution; INTENSITY-MODULATED RADIOTHERAPY; TOTAL-BODY IRRADIATION; HELICAL TOMOTHERAPY; TREATMENT PLANS; CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; QUALITY-ASSURANCE; NECK-CANCER; IMRT; ARC;
D O I
10.5114/wo.2012.27332
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim of the study: Helical tomotherapy is one of the methods of radiotherapy. This method enables treatment implementation for a wide spectrum of clinical cases. The vast array of therapeutic uses of helical tomotherapy results directly from the method of dose delivery, which is significantly different from the classic method developed for conventional linear accelerators. The paper discusses the method of dose delivery by a tomotherapy machine. Moreover, an analysis and presentation of treatment plans was performed in order to show the therapeutic possibilities of the applied technology. Dose distributions were obtained for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, tongue cancer, metastases to bones, and advanced skin cancer. Tomotherapy treatment plans were compared with conventional linear accelerator plans. Results: Following the comparative analysis of tomotherapy and conventional linear accelerator plans, in each case we obtained the increase in dose distribution conformity manifested in greater homogeneity of doses in the radiation target area for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, metastases to bones, and advanced skin cancer, and the reduction of doses in organs at risk (OAR) for anaplastic medulloblastoma, vulva cancer, tongue cancer, and advanced skin cancer. The time of treatment delivery in the case of a tomotherapy machine is comparable to the implementation of the plan prepared in intensity-modulated radiotherapy (IMRT) technique for a conventional linear accelerator. In the case of tomotherapy the application of a fractional dose was carried out in each case during one working period of the machine. For a conventional linear accelerator the total value of the fractional dose in the case of anaplastic medulloblastoma and metastases to bones was delivered using several treatment plans, for which a change of set-up was necessary during a fraction. Conclusion: The obtained results confirm that tomotherapy offers the possibility to obtain precise treatment plans together with the simplification of the therapeutic system.
引用
收藏
页码:16 / 25
页数:10
相关论文
共 50 条
  • [21] Dose verification in moving targets during helical tomotherapy beam delivery
    Zeidan, O.
    Langen, K.
    Meeks, S.
    Willoughby, T.
    Wagner, T.
    Kupelian, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2089 - 2089
  • [22] AN ANALYSIS ON DOSE COVERAGE IN BLADDER CANCER USING THE TOMOTHERAPY ADAPTIVE RADIOTHERAPY APPLICATION
    Althof, V.
    Niel, C.
    Altena, W.
    Bekhuis, E.
    Geukes, L.
    Oplaat, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S441 - S441
  • [23] Integral Dose in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Xie, C.
    Wang, J.
    CLINICAL ONCOLOGY, 2009, 21 (09) : 706 - 712
  • [24] TREATMENT PLANNING FOR PULSED REDUCED DOSE-RATE RADIOTHERAPY IN HELICAL TOMOTHERAPY
    Rong, Yi
    Paliwal, Bhudatt
    Howard, Steven P.
    Welsh, James
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03): : 934 - 942
  • [25] Cardiac dose evaluation in left breast cancer radiotherapy: Direct and Helical Tomotherapy
    Fozza, A.
    Berta, L.
    Aimonetto, S.
    Migliaccio, F.
    Cornetto, A. Peruzzo
    Vigna, L.
    Meloni, T.
    Munoz, F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S795 - S796
  • [26] Helical tomotherapy for moving objects - Analysis of the surface dose for the radiotherapy of the Mamma Carcinoma
    Zibold, F.
    Sterzing, F.
    Sroka-Perez, G.
    Schubert, K.
    Wagenknecht, K.
    Debus, J.
    Herfarth, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 99 - 99
  • [27] Dynamic tomotherapy delivery
    Chen, Yu
    Chen, Quan
    Chen, Mingli
    Lu, Weiguo
    MEDICAL PHYSICS, 2011, 38 (06) : 3013 - 3024
  • [28] Integral Dose Variation in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Zhou, G.
    Wang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S713 - S713
  • [29] Integral Dose Variation in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Wang, J.
    Xu, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Geometric and actual dose delivery accuracy in supine and prone position of breast tomotherapy
    Chiu, G.
    Fung, W. W. K.
    Wu, V. W. C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S596 - S597