Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

被引:13
|
作者
Yang, Yun [1 ]
Catalano, Suzanne [1 ]
Kelsey, Chris R. [1 ]
Yoo, David S. [1 ]
Yin, Fang-Fang [1 ]
Cai, Jing [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
Lung SBRT; Rotation; 6D correction; IGRT; RADIOTHERAPY; ERRORS; MARGINS; PATIENT; SETUP;
D O I
10.1016/j.meddos.2013.11.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1 degrees, 3 degrees, and 5 degrees in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V-100%), max PTV dose (PTV D-max), percentage prescription dose to 0.35 cc of cord (cord D-0.35 cc), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D-0.35 cc and D-5 cc), and volume of the lungs receiving at least 20 Gy (lung V-20). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1 Gy. Of all rotational offsets, largest change in PTV V-100%, PTV D-max, cord D-0.35 cc, esophagus D-0.35 cc, esophagus D-5 cc, and lung V-20 was - 8.36%, - 6.06%, 11.96%, 8.66%, 6.02%, and - 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R-2 range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5 degrees in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets. (C) 2014 American Association of Medical Dosimetrists.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [41] Daily Imaging and Dose Deformation for Assessment of Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Jiang, L.
    Foster, R.
    Bzdusek, K.
    Xiong, Y.
    Solberg, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [42] To Validate Dose Delivery in Static Field Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Joshi, C. P.
    Garcia, L.
    Olding, T.
    Alexander, K.
    Owen, T.
    Kerr, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Dosimetric evaluation of target dose in stereotactic body radiation therapy (SBRT) of lung using a dynamic motion anthropomorphic phantom
    Rassiah, P
    Tanyi, J
    Cheng, C
    Varchena, V
    Fuss, M
    Salter, B
    MEDICAL PHYSICS, 2004, 31 (06) : 1880 - 1880
  • [44] Stereotactic Body Radiation Therapy for Lung Cancer
    Simone, Charles B., II
    Wildt, Brian
    Haas, Andrew R.
    Pope, Greg
    Rengan, Ramesh
    Hahn, Stephen M.
    CHEST, 2013, 143 (06) : 1784 - 1790
  • [45] Salvage Stereotactic Body Radiation Therapy (SBRT) for Local Failure After Primary Lung SBRT
    Hearn, Jason W. D.
    Videtic, Gregory M. M.
    Djemil, Toufik
    Stephans, Kevin L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (02): : 402 - 406
  • [46] Long Term Outcomes Following Repeat Radiation Therapy (RT) to the Lung for Lung Cancer and Lung Metastases with Stereotactic Body Radiation Therapy (SBRT)
    Ricco, A.
    Barlow, S.
    Jacob, J.
    Feng, J.
    Hanlon, A.
    Arrigo, S. A.
    Obayomi-Davies, O., Jr.
    Lamond, J. P.
    Yang, J.
    Lanciano, R. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E583 - E584
  • [47] Repeat Thoracic Stereotactic Body Radiation Therapy (SBRT) for Nonsmall Cell Lung Cancer: Long-Term Outcomes, Toxicity, and Dosimetric Considerations
    Ricco, Anthony
    Barlow, Sara
    Feng, Jing
    Jacob, Janson
    Lozano, Alicia
    Hanlon, Alexandra
    Arrigo, Stephen
    Obayomi-Davies, Olusola
    Lamond, John
    Yang, Jun
    Lanciano, Rachelle
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (05) : 984 - 993
  • [48] Dosimetric Impact of Four Dose Calculation Algorithms On Stereotactic Body Radiation Therapy for Lung Cancer
    Kusunoki, T.
    Kurooka, M.
    Nonaka, T.
    Yoshino, S.
    Shioiri, K.
    Ide, S.
    Nakayama, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2967 - 2967
  • [49] Dosimetric Impact of Five Tumor Delineation Strategies in Stereotactic Body Radiation Therapy for Lung Cancer
    Wu, J.
    Betzing, C.
    Srisuthep, A.
    Fuss, M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2654 - +
  • [50] Stereotactic body radiation therapy (SBRT) in metastatic colorectal cancer (mCRC)
    Mireia, G. R.
    Marina, M. A.
    Ana, H. M.
    Maria Jose, S. A.
    Miriam, L. D. M.
    Silvia, C. F.
    Amaya, F. D.
    Alejandro, H. P.
    Jose, L. T.
    Carlos, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S792 - S793